Spectral domain optical coherence tomography for ex vivo brain tumor analysis (Englisch)

In: Proc. SPIE   ;  9541 ;  2015

Wie erhalte ich diesen Titel?

Download
Kommerziell Vergütung an den Verlag: 15,19 € Grundgebühr: 4,00 € Gesamtpreis: 19,19 €
Akademisch Vergütung an den Verlag: 15,19 € Grundgebühr: 2,00 € Gesamtpreis: 17,19 €

Non-contact imaging methods to distinguish between healthy tissue and brain tumor tissue during surgery would be highly desirable but are not yet available. Optical Coherence Tomography (OCT) is a non-invasive imaging technology with a resolution around 1-15 μm and a penetration depth of 1-2 mm that may satisfy the demands. To analyze its potential, we measured ex vivo human brain tumor tissue samples from 10 patients with a Spectral Domain OCT system (Thorlabs Callisto: center wavelength of 930 nm) and compared the results with standard histology. In detail, three different measurements were made for each sample. First the sample was measured directly after surgery. Then it was embedded in paraffin (also H and E staining) and examined for the second time. At last, the slices of each paraffin block cut by the pathology were measured. Each time a B-scan was created and for a better comparison with the histology a 3D image was generated, in order to get the corresponding en face images. In both, histopathological diagnosis and the analysis of the OCT images, different types of brain tumor showed difference in structure. This has been affirmed by two blinded investigators. Nevertheless the difference between two images of samples taken directly after surgery is less distinct. To enhance the contrast in the images further, we employ Spectroscopic OCT and pattern recognition algorithms and compare these results to the histopathological standard.

Inhaltsverzeichnis Konferenzband

Die Inhaltsverzeichnisse werden automatisch erzeugt und basieren auf den im Index des TIB-Portals verfügbaren Einzelnachweisen der enthaltenen Beiträge. Die Anzeige der Inhaltsverzeichnisse kann daher unvollständig oder lückenhaft sein.

95410B
Transillumination imaging through biological tissue by single-pixel detection
Durán, Vicente / Soldevila , Fernando / Irles, Esther / Clemente , Pere / Tajahuerce, Enrique / Andrés , Pedro / Lancis, Jesús | 2015
95410E
Spatial frequencies selection for speckle grain reduction through semi-transparent media
Di Battista, Diego / Ancora, Daniele / Avtzi, Stella / Leonetti, Marco / Zacharakis, Giannis | 2015
95410F
Time-encoded Raman scattering (TICO-Raman) with Fourier domain mode locked (FDML) lasers
Karpf, Sebastian / Eibl, Matthias / Wieser, Wolfgang / Klein, Thomas / Huber, Robert | 2015
95410J
Improved cancer diagnostics by different image processing techniques on OCT images
Kanawade, Rajesh / Lengenfelder, Benjamin / Marini Menezes, Tassiana / Hohmann, Martin / Kopfinger, Stefan / Hohmann, Tim / Grabiec, Urszula / Klämpfl, Florian / Gonzales Menezes, Jean / Waldner, Maximilian et al. | 2015
95410O
In vivo imaging of retinal and choroidal vasculature in the rodent eye using optical coherence tomography
Augustin, Marco / Fialová, Stanislava / Plasenzotti, Roberto / Pircher, Michael / Hitzenberger, Christoph K. / Baumann, Bernhard | 2015
95410P
Comparison of the polarization properties in the retinas of different rodents using high resolution polarization sensitive OCT
Fialová, Stanislava / Augustin, Marco / Plasenzotti, Roberto / Rauscher, Sabine / Gröger, Marion / Pircher, Michael / Hitzenberger, Christoph K. / Baumann, Bernhard | 2015
95410Q
Real-time optical coherence tomography observation of retinal tissue damage during laser photocoagulation therapy on ex-vivo porcine samples
Steiner, P. / Považay, B. / Stoller, M. / Morgenthaler, P. / Inniger, D. / Arnold, P. / Sznitman, R. / Meier, Ch. | 2015
95410R
Imaging the tympanic membrane oscillation ex vivo with Doppler optical coherence tomography during simulated Eustachian catarrh
Kirsten, Lars / Burkhardt, Anke / Golde, Jonas / Walther, Julia / Stoppe, Thomas / Bornitz, Matthias / Kemper, Max / Zahnert, Thomas / Koch, Edmund | 2015
95410V
4D optical coherence tomography of aortic valve dynamics in a murine mouse model ex vivo
Schnabel, Christian / Jannasch, Anett / Faak, Saskia / Waldow, Thomas / Koch, Edmund | 2015
95410Z
High definition in vivo retinal volumetric video rate OCT at 0.6 Giga-voxels per second
Kolb, Jan Philip / Klein, Thomas / Wieser, Wolfgang / Draxinger, Wolfgang / Huber, Robert | 2015
95411A
Iterative Otsu's method for OCT improved delineation in the aorta wall
Alonso, Daniel / Real, Eusebio / Val-Bernal, José F. / Revuelta, José M. / Pontón, Alejandro / Calvo Díez, Marta / Mayorga, Marta / López-Higuera, José M. / Conde, Olga M. | 2015
95411C
Frequency sweep jitter and wander of a Vernier-Tuned Distributed Bragg Reflector (VT-DBR) laser at 1550 nm in OCT applications
Martens Biersach, R. C. / Derickson, Dennis / Ensher, Jason | 2015
95411D
Spectral domain optical coherence tomography for ex vivo brain tumor analysis
Lenz, Marcel / Krug, Robin / Jaedicke, Volker / Stroop, Ralf / Schmieder, Kirsten / Hofmann, Martin R. | 2015
95411F
An algorithm for simulating image formation in optical coherence tomography for cylinder scattering
Brenner, Thomas / Reitzle, Dominik / Kienle, Alwin | 2015
95411G
Optimal integration time in OCT imaging
Martin, Lorenz / Gräub, Stephan / Meier, Christoph | 2015
95411H
Motion artefacts simulation in the imaging of the ocular media
Zakharov, P. / Talary, M. S. / Boss, D. / Mrochen, M. | 2015
95411I
Investigation of changes in fractal dimension from layered retinal structures of healthy and diabetic eyes with optical coherence tomography
Gao, Wei / Zakharov, Valery P. / Myakinin, Oleg O. / Bratchenko, Ivan A. / Artemyev, Dmitry N. / Kornilin, Dmitry V. | 2015
95411K
Speckle reduction process based on digital filtering and wavelet compounding in optical coherence tomography for dermatology
Gómez Valverde, Juan J. / Ortuño , Juan E. / Guerra , Pedro / Hermann, Boris / Zabihian, Behrooz / Rubio-Guivernau, José L. / Santos, Andrés / Drexler, Wolfgang / Ledesma-Carbayo, Maria J. | 2015
954101
Front Matter: Volume 9541
| 2015
954102
Optimal processing of Doppler signals in OCT
Walther, Julia / Kirsten, Lars / Koch, Edmund | 2015
954106
An approach to OCT-based microvascular imaging using reference-free processing of complex valued B-scans
Matveev, Lev A. / Gelikonov, Grigory V. / Matveyev, Alexandr L. / Moiseev, Alexander A. / Ksenofontov, Sergey / Gelikonov, Valentin M. / Sirotkina, Marina A. / Buyanova, Natalia L. / Gladkova, Natalia D. / Demidov, Valentin et al. | 2015
954107
Flow rate estimation by optical coherence tomography using contrast dilution approach
Štohanzlová, Petra / Kolář, Radim | 2015
954112
En faceprojection imaging of the human choroidal layers with tracking SLO and swept source OCT angiography methods
Gorczynska, Iwona / Migacz, Justin / Zawadzki, Robert J. / Sudheendran, Narendran / Jian, Yifan / Tiruveedhula, Pavan K. / Roorda, Austin / Werner, John S. | 2015
954116
Fully automated 1.5 MHz FDML laser with more than 100mW output power at 1310 nm
Wieser, Wolfgang / Klein, Thomas / Draxinger, Wolfgang / Huber, Robert | 2015
Feedback