Simple adaptive PI controller development and evaluation for mean arterial pressure regulation (Englisch)

In: Research on Biomedical Engineering   ;  35 ,  2  ;  157-165  ;  2019

Wie erhalte ich diesen Titel?

Download
Kommerziell Vergütung an den Verlag: 34,95 € Grundgebühr: 4,00 € Gesamtpreis: 38,95 €
Akademisch Vergütung an den Verlag: 12,50 € Grundgebühr: 2,00 € Gesamtpreis: 14,50 €

Abstract

Purpose

The automatic control of mean arterial pressure (MAP) in post-cardiac surgery has many advantages for patients and medical staff. However, it is a challenging problem for the control engineering and biomedical engineering community. Successfully developed controllers in the research environment have not been successful in the market because of their complex implementation, complicated operation, and inadequate capabilities performance across the range of patient variabilities. This paper describes the development and testing of a simple embedded adaptive PI controller for automatic MAP regulation of a known range of patients.

Methods

The developed controller is a synergistic combination of simple and proved schemes that have complementary characteristics; it is a parameter estimator for identification of patient MAP parameters, calculation of patient sensitivity, and adjustment of gains of a specific proportional-integral controller for the identified patient. The controller was implemented in Matlab/Simulink for desktop simulation along with a MAP model that allows the variation of the type of patient tested. In addition to the desktop simulation, an embedded version of the controller implemented in ARM Cortex M3 low-cost microcontroller was tested on a hardware-in-the-loop (Hil) simulation along with a real-time MAP model embedded in ARM Cortex A7 single board computer.

Results

Both simulations (desktop and hardware-in-the-loop) presented similar results, meeting the established MAP regulation performance criteria: settling time less than 600 s, overshoot less than 10 mmHg, and steady-state error about setpoint less than 5 mmHg. The results achieved are as follows: settling time between 170 and 330 s, overshoot between 1 and 4 mmHg, and steady-state errors about setpoint less than 3 mmHg, across the range of MAP patients considered. The controller developed in this work is a viable alternative to the complicated identification and control techniques normally employed for automatic MAP regulation.

Conclusion

An adaptive, simple PI controller for adjusting the MAP and having low computational cost was developed and embedded in a low-cost microcontroller. The controller was evaluated via desktop and Hil simulation across the known range of MAP parameters of patients, with successful regulation of MAP in all cases considered.

Inhaltsverzeichnis – Band 35, Ausgabe 2

Zeige alle Jahrgänge und Ausgaben

Die Inhaltsverzeichnisse werden automatisch erzeugt und basieren auf den im Index des TIB-Portals verfügbaren Einzelnachweisen der enthaltenen Beiträge. Die Anzeige der Inhaltsverzeichnisse kann daher unvollständig oder lückenhaft sein.

77
Cycling fatigue evaluation using weighted-cumulated methodology
Oliveira Nascimento, Francisco Assis / Araújo Rocha, Valdinar Jr / Andrade, Marcelino Monteiro / Carmo, Jake Carvalho | 2019
89
Automatic optic disc segmentation using a 3D Morphologic Fuzzy Histon Roughness Index
Cardoso, Cristiane de Fátima dos Santos / Carrijo, Gilberto Arantes / Ferreira, Júlio César / Santos, Jucelino Cardoso Marciano | 2019
103
Incisions in virtual reality simulators: assessing user performance
Moura, Ives Fernando Martins Santos / Machado, Liliane dos Santos / Valença, Ana Maria Gondim | 2019
111
On the origin of skin burns and neuromuscular electrical stimulation as a consequence of electrosurgical procedures
Dias, Elton Jr / Schneider, Bertoldo Jr / Ribeiro, Evaldo | 2019
123
Whole-body vibration on parallel bar device for gait and balance rehabilitation in stroke patients
Morais, Antonio Vinícius / Tomaz, Gilberto Jr / Lazzareschi, Leandro / Almeida, Diego Varalda / Santos, Marcello Francisco / Silva Boschi, Silvia Regina Matos / Martini, Silvia Cristina / Scardovelli, Terigi Augusto / Silva, Alessandro Pereira | 2019
131
Scaffolds’ production based on calcium aluminate blends and their biological properties
Las Nieves González Vicuna, Iranel / Grancianinov, Karen Julie Santos / Santos, Kennedy Wallace / Santos Ortega, Fernando / Camargo Reis Mello, Daphne / Vasconcellos, Luana Marotta Reis / Costa, Maricilia Silva / Pandolfelli, Victor Carlos / Oliveira, Ivone Regina | 2019
143
Automated ECG heartbeat classification by combining a multilayer perceptron neural network with enhanced particle swarm optimization algorithm
Bouaziz, Fatiha / Boutana, Daoud | 2019
157
Simple adaptive PI controller development and evaluation for mean arterial pressure regulation
Silva, Samuel Justino / Scardovelli, Terigi Augusto / Silva Boschi, Silvia Regina Matos / Rodrigues, Silvia Cristina Martini / Silva, Alessandro Pereira | 2019
167
An obstetric brachial plexus lesion rehabilitation platform
Alberti, Eduardo Juliano / Pichorim, Sérgio Francisco / Brawerman, Alessandro | 2019
Feedback