Radiation protection dosimetry
The tables of contents are generated automatically and are based on the data records of the individual contributions available in the index of the TIB portal. The display of the Tables of Contents may therefore be incomplete.
Table of contents
- 1
-
European conference on Individual Monitoring of Ionising Radiation (IM2010)Kamenopoulou, Vasiliki / Mundigl, Stefan / Czarwinski, Renate et al. | 2011
- 2
-
Occupational exposures worldwide and revision of international standards for protectionCzarwinski, R. / Crick, M. J. et al. | 2011
- 12
-
Revision of the Euratom Basic Safety Standards Directive--current statusMundigl, Stefan et al. | 2011
- 17
-
The new EC technical recommendations for monitoring individuals occupationally exposed to external radiationAlves, J. G. / Ambrosi, P. / Bartlett, D. T. et al. | 2011
- 26
-
International standards for radiation protectionAmbrosi, Peter et al. | 2011
- 33
-
IEC standards for individual monitoring of ionising radiationVoytchev, M. / Ambrosi, P. / Behrens, R. et al. | 2011
- 37
-
Monte Carlo determination of the conversion coefficients Hp(3)/Ka in a right cylinder phantom with 'PENELOPE' code. Comparison with 'MCNP' simulationsDaures, J. / Gouriou, J. / Bordy, J. M. et al. | 2011
- 43
-
Application of ISO Standard 27048: dose assessment for the monitoring of workers for internal radiation exposureHenrichs, K. et al. | 2011
- 47
-
Accreditation of testing laboratories in dosimetry: the use of a flexible scope at the Competent Incorporation Measuring Body JulichHill, P. / Froning, M. / Schläger, M. et al. | 2011
- 47
-
Accreditation of testing laboratories in dosimetry: the use of a flexible scope at the Competent Incorporation Measuring Body JülichHill et al. | 2010
- 52
-
Occupational dose assessment and National Dose Registry System in IranJafari-zadeh, M. / Nazeri, F. / Hosseini-Pooya, S. M. et al. | 2011
- 56
-
Developments in uncertainty analysis for individual monitoringvan Dijk, J. W. E. et al. | 2011
- 62
-
Different versions of the right answer: the importance of measurement uncertainty in radiation dosimetryGilvin, Phil / McWhan, Andrew et al. | 2011
- 67
-
Uncertainty assessment of a two element LiF:Mg,Ti TL personal dosemeter using Monte-Carlo techniquesStadtmann, H. / Hranitzky, C. et al. | 2011
- 72
-
The national dose register in FinlandLehtinen, M. / Havukainen, R. et al. | 2011
- 76
-
Fifty years of individual monitoring of ionising radiation in Switzerland: history, trends and perspectivesMoser, M. / Elmiger, R. / Frei, D. et al. | 2011
- 80
-
Radiation protection for pregnant workers and their offspring: a recommended approach for monitoringCruz-Suarez, Rodolfo / Nosske, Dietmar / Souza-Santos, Denison et al. | 2011
- 85
-
Quality assurance of testing methods in incorporation monitoring at the officially recognised incorporation measurement office at Julich, GermanyFroning, M. / Hill, P. / Burow, M. et al. | 2011
- 85
-
Quality assurance of testing methods in incorporation monitoring at the officially recognised incorporation measurement office at Jülich, GermanyFroning et al. | 2010
- 90
-
Reliability in individual monitoring serviceMod Ali, N. et al. | 2011
- 95
-
Quality management system and accreditation of the in vivo monitoring laboratory at Karslruhe Institue of TechnologyBreustedt, B. / Mohr, U. / Biegard, N. et al. | 2011
- 98
-
Experience of introducing a new database for an approved coordination and recordkeeping serviceGarratt, N. J. et al. | 2011
- 102
-
Practical low dose limits for passive personal dosemeters and the implications for uncertainties close to the limit of detectionGilvin, P. J. / Perks, C. A. et al. | 2011
- 107
-
Dose levels of the occupational radiation exposures in Poland based on results from the accredited dosimetry service at the IFJ PAN, KrakowBudzanowski, Maciej / Kopec, Renata / Obryk, Barbara et al. | 2011
- 111
-
Quality management system in the CIEMAT Radiation Dosimetry ServiceMartín, R. / Navarro, T. / Romero, A. M. et al. | 2011
- 115
-
Brazilian External Occupational Dose Management SystemMauricio, Claudia L. P. / da Silva, Herica L. R. / da Silva, Claudio Ribeiro et al. | 2011
- 119
-
Occupational exposure control: the problem of quantities in radiation protectionSabol, J. / Navrátil, L. / Rosina, J. et al. | 2011
- 124
-
Accreditation and training on internal dosimetry in a laboratory network in Brazil: an increasing demandDantas, B. M. / Dantas, A. L. A. / Acar, M. E. D. et al. | 2011
- 130
-
A Brazilian government external individual monitoring service: experience since 1972Mauricio, Claudia L. P. / Martins, Marcelo M. / Ramos, Elisabete Vargas et al. | 2011
- 137
-
Quality assurance programme implemented in the Whole Body Monitoring Laboratory of IFIN-HH RomaniaSaizu, M. A. et al. | 2011
- 140
-
Evaluation of the performance of two LiF:Mg,Ti and LiF:Mg,Cu,P dosemeters for extremity monitoringFreire, L. C. / Pereira, M. F. / Calado, A. M. et al. | 2011
- 144
-
Performance and approval procedures for active personal dosemetersGinjaume, M. et al. | 2011
- 150
-
Influence of variation of etching conditions on the sensitivity of PADC detectors with a new evaluation methodFiechtner-Scharrer, A. / Mayer, S. / Boschung, M. et al. | 2011
- 155
-
Neutron response characterisation of an OSL neutron dosemeterPassmore, C. / Kirr, M. et al. | 2011
- 161
-
The applicability of the PTTL dose re-analysis method to the Harshaw LiF:Mg,Cu,P materialMoscovitch, M. / Benevides, L. / Romanyukha, A. et al. | 2011
- 165
-
Uncertainties associated with the use of optically stimulated luminescence in personal dosimetrydaggerBenevides, L. / Romanyukha, A. / Hull, F. et al. | 2011
- 165
-
Uncertainties associated with the use of optically stimulated luminescence in personal dosimetryBenevides, L. / Romanyukha, A. / Hull, F. et al. | 2011
- 168
-
Development of a new ionisation chamber, for HP(10) measurement, using Monte-Carlo simulation and experimental methodsSilva, H. / Cardoso, J. / Oliveira, C. et al. | 2011
- 173
-
The use of active personal dosemeters as a personal monitoring device: comparison with TL dosimetryBoziari, A. / Koukorava, C. / Carinou, E. et al. | 2011
- 177
-
Preliminary results on bubble detector as personal neutron dosemeterPonraju, D. / Krishnan, H. / Viswanathan, S. et al. | 2011
- 182
-
A Monte Carlo simulation of monoenergetic neutrons traversing rectangular and spherical polyethylene moderatorsMonk, S. D. / Selwood, M. et al. | 2011
- 187
-
ENEA extremity dosemeter based on LiF(Mg,Cu,P) to evaluate Hp(3,{alpha})Mariotti, F. / Fantuzzi, E. / Morelli, B. et al. | 2011
- 187
-
ENEA extremity dosemeter based on LiF(Mg,Cu,P) to evaluate Hp(3,a)Mariotti, F. / Fantuzzi, E. / Morelli, B. et al. | 2011
- 187
-
ENEA extremity dosemeter based on LiF(Mg,Cu,P) to evaluate Hp(3,)Mariotti et al. | 2011
- 192
-
Long-term stability of Harshaw LiF:Mg,Cu,P TLDSGilvin, P. J. / Burkett, R. A. / Baker, S. T. et al. | 2011
- 195
-
A method of identification of abnormal glow curves in individual monitoring using CaSO4:Dy Teflon TLD and hot gas readerPradhan, S. M. / Sneha, C. / Adtani, M. M. et al. | 2011
- 199
-
UV-induced bleaching of deep traps in Harshaw TLD LiF:Mg,Cu,P and LiF:Mg,TiBenevides, L. / Voss, S. / Nita, I. et al. | 2011
- 202
-
Removing spurious signals from glow curves using an optimal Wiener filtervan Dijk, J. W. E. / Stadtmann, H. / Grimbergen, T. W. M. et al. | 2011
- 207
-
Pre- and post-irradiation fading effect for LiF:Mg,Ti and LiF:Mg,Cu,P materials used in routine monitoringCarinou, E. / Askounis, P. / Dimitropoulou, F. et al. | 2011
- 211
-
Energy response of different types of RADOS personal dosemeters with MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) TL detectorsObryk, B. / Hranitzky, C. / Stadtmann, H. et al. | 2011
- 215
-
Brazilian gamma-neutron dosemeter: response to 241AmBe and 252Cf neutron sourcesSouto, E. B. / Campos, L. L. et al. | 2011
- 218
-
Simulating Makrofol as a detector for neutron-induced recoilsZhang, G. / Becker, F. / Urban, M. et al. | 2011
- 222
-
Development of confocal laser microscope system for examination of microscopic characteristics of radiophotoluminescence glass dosemetersMaki, Daisuke / Ishii, Tetsuya / Sato, Fuminobu et al. | 2011
- 226
-
Development of thermal neutron-sensitive glass dosemeter containing lithiumMaki, Daisuke / Kobayashi, Hatsumi / Sato, Fuminobu et al. | 2011
- 231
-
Personal monitor glass badge: theoretical dosemeter response calculated with the Monte Carlo transport code MCNPXHocine, Nora / Donadille, Laurent / Huet, Christelle et al. | 2011
- 234
-
The thermoluminescence efficiency of Li2B4O7:Cu and of CaSO4:Tm for photonsOtto, Th. / Gindraux, L. / Strasser, M. et al. | 2011
- 239
-
Automation of film densitometry for application in personal monitoringTaheri, M. / Movafeghi, A. / Rastkhah, N. et al. | 2011
- 243
-
Evaluating the performance of the HarshawTM DXTRAD LiF:Mg,Cu,P finger ring with two different thickness filtersBaker, S. T. / Roberts, G. H. / Gilvin, P. J. et al. | 2011
- 243
-
Evaluating the performance of the Harshaw™ DXTRAD LiF:Mg,Cu,P finger ring with two different thickness filtersBaker et al. | 2011
- 246
-
A whole-body dosimetry system for personal monitoring based on hot-pressed thin layer TLDBusch, F. / Engelhardt, J. / Martini, E. et al. | 2011
- 249
-
Construction issues surrounding a portable four-band neutron detection systemSelwood, M. J. / Monk, S. D. et al. | 2011
- 253
-
Linear vs. function-based dose algorithm designsStanford, N. et al. | 2011
- 257
-
Principles for the design and calibration of radiation protection dosemeters for operational and protection quantities for eye lens dosimetryBordy, J. M. / Gualdrini, G. / Daures, J. et al. | 2011
- 262
-
A comparative study of the responses of lithium borate and calcium sulphate phosphors in a TL personal dosemeterCeretti, M. / Costa, G. / Romani, S. et al. | 2011
- 266
-
EURADOS self-sustained programme of intercomparisons for individual monitoring servicesGrimbergen, T. W. M. / Figel, M. / Romero, A. M. et al. | 2011
- 275
-
Results of the EURADOS extremity dosemeter intercomparison 2009Stadtmann, H. / Grimbergen, T. W. M. / Figel, M. et al. | 2011
- 282
-
Intercomparison on measurements of the quantity personal dose equivalent Hp(10) in photon fields in the African regionMsimang, Z. / Cruz-Suárez, R. / Zeger, J. et al. | 2011
- 287
-
National and international interlaboratories comparisons: a tool for the validation of in vitro and in vivo methodsBérard, Philippe / Franck, Didier et al. | 2011
- 291
-
IAEA regional intercomparison of in vivo measurements of 131I in the thyroid: the Latin American and Caribbean experienceDantas, B. M. / Dantas, A. L. A. / Santos, D. S. et al. | 2011
- 295
-
EURADOS intercomparison on measurements and Monte Carlo modelling for the assessment of americium in a USTUR leg phantomLopez, M. A. / Broggio, D. / Capello, K. et al. | 2011
- 300
-
Intercomparison exercise within a distributed-dosimetry networkRomanyukha, A. / Voss, S. P. / Benevides, L. A. et al. | 2011
- 300
-
Intercomparison exercise within a distributed-dosimetry networkdaggerRomanyukha, A. / Voss, S. P. / Benevides, L. A. et al. | 2011
- 306
-
Hp(0.07) photon irradiations at Seibersdorf for the EURADOS extremity dosemeter intercomparison 2009Stadtmann, H. / Hranitzky, C. et al. | 2011
- 310
-
Latin American and Caribbean intercomparison of surface contamination monitoring equipmentCabral, T. S. / Ramos, M. M. O. / Laranjeira, A. S. et al. | 2011
- 314
-
New developments in internal dosimetry modelsNoßke, D. / Blanchardon, E. / Bolch, W. E. et al. | 2011
- 321
-
Measuring an 'active person' with the HMLs emergency response instrumentsKramer, Gary H. / Hauck, Barry M. et al. | 2011
- 326
-
Variability of radioiodine measurements in the thyroidDamet, J. / Bochud, F. O. / Bailat, C. et al. | 2011
- 330
-
The extraction of thorium by calix[6]arene columns for urine analysisMekki, S. / Bouvier-Capely, C. / Jalouali, R. et al. | 2011
- 335
-
Development and validation of a technique for the determination of 226Ra and 228Ra by liquid scintillation in liquid samplesFernandes, Paulo César P. / Sousa, Wanderson O. / Julião, Ligia M. Q. C. et al. | 2011
- 339
-
Theoretical assessment of whole body counting performances using numerical phantoms of different gender and sizesMarzocchi, O. / Breustedt, B. / Mostacci, D. et al. | 2011
- 344
-
Examples of Mesh and NURBS modelling for in vivo lung counting studiesFarah, Jad / Broggio, David / Franck, Didier et al. | 2011
- 349
-
EURADOS coordinated action on research, quality assurance and training of internal dose assessmentsLopez, M. A. / Balásházy, I. / Bérard, P. et al. | 2011
- 353
-
Particle clearance in the alveolar-interstitial region of the human lungs: model validationGregoratto, D. / Bailey, M. R. / Marsh, J. W. et al. | 2011
- 357
-
Head calibration phantoms for actinides: measurements and simulationsVrba, T. et al. | 2011
- 361
-
Optimisation of internal contamination monitoring programme by integration of uncertaintiesDavesne, E. / Casanova, P. / Chojnacki, E. et al. | 2011
- 367
-
Individual monitoring of internal exposure at the shelter objectBonchuk, I. / Likhtarev, I. / Berkovski, V. et al. | 2011
- 371
-
MADOR: a new tool to calculate decrease of effective doses in human after DTPA therapyFritsch, P. / Grémy, O. / Hurtgen, C. et al. | 2011
- 376
-
Design and testing of a new stand for the BOMAB family of phantomsHauck, Barry M. / Kramer, Gary H. / Capello, Kevin et al. | 2011
- 379
-
Estimation of uranium GI absorption fractions for children and adultsChen, J. / Lariviere, D. / Timmins, R. et al. | 2011
- 384
-
Comparison of various anthropomorphic phantom types for in vivo measurements by means of Monte Carlo simulationsSchläger, Martin et al. | 2011
- 389
-
A new position recording system for the partial-body counter at KITHegenbart, Lars / Breustedt, Bastian et al. | 2011
- 393
-
Assessment of uranium exposure from total activity and 234U:238U activity ratios in urineNicholas, T. / Bingham, D. et al. | 2011
- 398
-
Characterisation of the PSI whole body counter by radiographic imagingMayer, S. / Boschung, M. / Meier, K. et al. | 2011
- 402
-
Simulation of phoswich detectors using MCNPX and EGSNRCLeone, D. / Breustedt, B. et al. | 2011
- 407
-
Evaluation of counting efficiencies of a whole-body counter using Monte Carlo simulation with voxel phantomsTakahashi, Masa / Kinase, Sakae / Kramer, Richard et al. | 2011
- 411
-
Efficiency calibration of a whole-body-counting measurement setup using a modular physical phantomLebacq, A. L. / Bruggeman, M. / Vanhavere, F. et al. | 2011
- 415
-
A high-sensitivity multidetector whole-body counterKalef-Ezra, J. A. / Valakis, S. T. / Soupsanas, T. et al. | 2011
- 419
-
Minimum detectable annual dose calculation for routine individual monitoring programme in case of plutonium and uranium contamination of the workplaceMolokanov, A. A. / Kukhta, B. A. / Yatsenko, V. N. et al. | 2011
- 423
-
Hair analysis as an indicator of exposure to uraniumKehagia, K. / Bratakos, S. / Kolovou, M. et al. | 2011
- 427
-
Calibration of phoswich-based lung counting system using realistic chest phantomManohari, M. / Mathiyarasu, R. / Rajagopal, V. et al. | 2011
- 433
-
The whole-body counting facility at the Swedish Radiation Safety Authority after relocationdel Risco Norrlid, L. / Östergren, I. et al. | 2011
- 437
-
International project on individual monitoring and radiation exposure levels in interventional cardiologyPadovani, R. / Le Heron, J. / Cruz-Suarez, R. et al. | 2011
- 442
-
Extremity and eye lens doses in interventional radiology and cardiology procedures: first results of the ORAMED projectDomienik, J. / Brodecki, M. / Carinou, E. et al. | 2011
- 448
-
Preliminary assessment of the dose to the interventional radiologist in fluoro-CT-guided proceduresPereira, M. F. / Alves, J. G. / Sarmento, S. et al. | 2011
- 453
-
Active personal dosemeters in interventional radiology: tests in laboratory conditions and in hospitalsClairand, I. / Bordy, J.-M. / Daures, J. et al. | 2011
- 459
-
Dose measurement for medical staff with glass dosemeters and thermoluminescence dosemeters during 125I brachytherapy for prostate cancerFujii, K. / Ko, S. / Nako, Y. et al. | 2011
- 464
-
Individual monitoring of internal exposure for nuclear medicine workers in SwitzerlandBaechler, S. / Stritt, N. / Bochud, F. O. et al. | 2011
- 468
-
Assessment of internal contamination hazard and fast monitoring for workers involved in maintenance operations on PET cyclotronsTerranova, Nicholas / Testoni, Raffaella / Cicoria, Gianfranco et al. | 2011
- 473
-
Eye lens dosimetry: task 2 within the ORAMED projectGualdrini, G. / Mariotti, F. / Wach, S. et al. | 2011
- 478
-
Determination of the dose to persons assisting when X-radiation is used in medicine, dentistry and veterinary medicineHupe, O. / Ankerhold, U. et al. | 2011
- 482
-
Doses to operators during interventional radiology procedures: focus on eye lens and extremity dosimetryKoukorava, C. / Carinou, E. / Simantirakis, G. et al. | 2011
- 487
-
Deriving staff and public doses in a PET/CT facility from measured radiation levels using thermoluminescent dosimetryAl-Haj, Abdalla N. / Lobriguito, Aida M. / Arafah, Ahnaf et al. | 2011
- 492
-
Monte Carlo calculations on extremity and eye lens dosimetry for medical staff at interventional radiology proceduresCarinou, E. / Ferrari, P. / Koukorava, C. et al. | 2011
- 497
-
Simulation of beta radiator handling procedures in nuclear medicine by means of a movable hand phantomBlunck, Ch. / Becker, F. / Urban, M. et al. | 2011
- 501
-
Occupational exposure doses in interventional procedures in Bosnia and HerzegovinaBasic, B. / Beganovic, A. / Skopljak-Beganovic, A. et al. | 2011
- 505
-
Calibration of surface contamination monitors for the detection of iodine incorporation in the thyroid glandBailat, C. / Buchillier, T. / Baechler, S. et al. | 2011
- 510
-
Nuclear medicine annual external occupational dose distribution: Rio de Janeiro, Brazil, year 2005Mauricio, Claudia L. P. / Lima, Ana L. S. / da Silva, Herica L. R. et al. | 2011
- 515
-
Extremity exposure in nuclear medicine: preliminary results of a European studySans Merce, M. / Ruiz, N. / Barth, I. et al. | 2011
- 521
-
Individual monitoring in nuclear medicine therapeutic procedures using extremity dosemeters LiF(Mg, Cu, P)Sarti, G. / Del Dottore, F. / Fabbri, C. et al. | 2011
- 525
-
Ethical issues related to professional exposure of pregnant women in the medical field: monitoring and limiting effective doseSantos, J. A. M. / Nunes, R. et al. | 2011
- 530
-
Occupational exposure to staff during endoscopic retrograde cholangiopancreatography in SudanSulieman, A. / Elzaki, M. / Khalil, M. et al. | 2011
- 534
-
Triage, monitoring and dose assessment for people exposed to ionising radiation following a malevolent actEtherington, G. / Rothkamm, K. / Shutt, A. L. et al. | 2011
- 540
-
Numerical dosimetric reconstruction of a radiological accident in South America in April 2009Courageot, E. / Huet, C. / Clairand, I. et al. | 2011
- 543
-
Method of thermoluminescent measurement of radiation doses from micrograys up to a megagray with a single LiF:Mg,Cu,P detectorObryk, Barbara / Bilski, Pawel / Olko, Pawel et al. | 2011
- 548
-
Individual and workplace monitoring measurements made after a 240Pu incident and during the clean-up operationsHochmann, R. / Eisenwagner, H. / Benesch, T. et al. | 2011
- 551
-
The design of radiation accident registryChen, Jing / Seely, Bob / Bergman, Lauren et al. | 2011
- 555
-
A comparison between Monte Carlo-calculated and -measured total efficiencies and energy resolution for large plastic scintillators used in whole-body countingNilsson, J. / Isaksson, M. et al. | 2011
- 560
-
Cases of post-accident contamination with iodine 131I, registered in the Institute of Atomic Energy POLATOM in Swierk, PolandOsko, J. / Golnik, N. / Pliszczynski, T. et al. | 2011
- 564
-
Development of a new CBR-based platform for human contamination emergency situationsFarah, J. / Henriet, J. / Broggio, D. et al. | 2011
- 571
-
Overview of physical and biophysical techniques for accident dosimetryTrompier, F. / Bassinet, C. / Della Monaca, S. et al. | 2011
- 575
-
Recalibration of indium foil for personnel screening in criticality accidentsTakada, C. / Tsujimura, N. / Mikami, S. et al. | 2011
- 580
-
Dose reconstruction using mobile phonesBeerten, K. / Reekmans, F. / Schroeyers, W. et al. | 2011