Radiation protection dosimetry
The tables of contents are generated automatically and are based on the data records of the individual contributions available in the index of the TIB portal. The display of the Tables of Contents may therefore be incomplete.
Table of contents
- 0-xvii
-
Editorial - Ninth Solid State Dosimetry ConferenceDuftschmid, K.E. / Scharmann, A. et al. | 1990
- 1
-
The Present State of Track Etch Processes in Radiation DosimetryTommasino, L. et al. | 1990
- 5
-
A New Development of Dyed ECE Tracks for Radiation DosimetrySohrabi, M. / Sadeghi Bajd, S. et al. | 1990
- 9
-
Fast Neutron Spectrometry Using CR-39 Track DetectorsDajkó, G. et al. | 1990
- 13
-
Ultra Heavy Ion LET Determination with Solid State Nuclear Track DetectorsDomingo, C. / Baixeras, C. / Fernández, F. et al. | 1990
- 17
-
The NRPB PADC Neutron Personal Dosemeter: Recent DevelopmentsTanner, R.J. / Gilvin, P.J. / Steele, J.D. et al. | 1990
- 21
-
Neutron Dosimetry with SSNTDs and Spark Counting EvaluationSchmidt, W.F.O. et al. | 1990
- 25
-
Electrochemically Etched Makrofol DE as a Detector for Neutron Induced Recoils and Alpha ParticlesJózefowicz, K. / Piesch, E. et al. | 1990
- 29
-
Fractal Analysis of SSNTD Detectors and MaterialsEspinosa, G. / Castaño, V.M. et al. | 1990
- 31
-
Use of Solid State Nuclear Track Detectors in National Radiation Protection Monitoring ProgrammesGuhr, A. / Kraus, W. / Rimpler, A. et al. | 1990
- 35
-
An Improved CR-39 Detector Material with Low Background for Alpha and Neutron MeasurementsGuhr, A. / Sarenio, O. / Lassary, D. et al. | 1990
- 39
-
Simultaneous Measurement of Angle of Incidence and Energy in Fast Neutron Fields by CR-39Guldbakke, S. / Pitt, E. / Scharmann, A. et al. | 1990
- 43
-
The Effect of the Registration Temperature on the Response of CR-39 to Alpha Particles and Fission FragmentsDurrani, S.A. / Karamdoust, N.A. / Al-Khalifa, I.J.M. et al. | 1990
- 47
-
Neutron Dosimetry by UV and IR Spectrophotometry of the Newly Developed Dyed ECE TracksSohrabi, M. / Sadeghi Bajd, S. et al. | 1990
- 51
-
Revelation of Nuclear Tracks in Plastic Nuclear Track Detectors by Ultrasonic EtchingSu, C-S. et al. | 1990
- 55
-
TLD Methods in Archaeometry, Geology and Sediment StudiesAitken, M.J. et al. | 1990
- 61
-
The Via Nova-Via Sacra Archiac Site on Palatino Hill: First Thermoluminescence Archaeometric ResultsBacci, C. / Bernardini, P. / Furetta, C. et al. | 1990
- 65
-
Relationship of Anomalous Fading to Feldspar Inclusions in QuartzFragoulis, D. / Stoebe, T.G. et al. | 1990
- 69
-
Dating of Austrian Loess DepositsWallner, G. / Wild, E. / Aref-Azar, H. et al. | 1990
- 73
-
Photoluminescence Dating on the Alkali Feldspars: Physical Background, Equipment and Some ResultsHutt, G.I. / Yaek, I.V. et al. | 1990
- 75
-
The Optical Dating of Sediments Using QuartzSmith, B.W. / Rhodes, E.J. / Stokes, S. et al. | 1990
- 79
-
Lyoluminescence of Calcium Carbonate and Possible Applications in the Dating of Loess and SoilsCopty-Wergles, K. / Nowotny, R. / Hille, P. et al. | 1990
- 83
-
Archaeological Dating by Infrared-Stimulated Luminescence Using a Diode ArraySpooner, N.A. / Aitken, M.J. / Smith, B.W. et al. | 1990
- 87
-
Performance, Requirements and Testing in Individual MonitoringJulius, H.W. / Christensen, P. / Marshall, T.O. et al. | 1990
- 93
-
Electronic Personal DosemetersMarshall, T.O. / Bartlett, D.T. / Burgess, P.H. et al. | 1990
- 99
-
Uniformity and Stability of LiF Sensitivity - A Review of Fourteen Years' Monitoring ExperienceGrogan, D. / Bradley, R.P. / Mattioli, A. et al. | 1990
- 103
-
Recent Developments in Detectors for Photon and Neutron DosimetryDörschel, B. et al. | 1990
- 107
-
Comparison of Evaluation Methods for LiF Thermoluminescence Dosemeters for Measuring Photon Dose EquivalentsWill, W. et al. | 1990
- 111
-
Dosemeter Configurations for the Measurement of Hs(0.07) and Hp(10) from PhotonsChristensen, P. / Bøtter-Jensen, L. / Ennow, K. et al. | 1990
- 115
-
The IAEA Intercomparison for Individual MonitoringGriffith, R.V. / Böhm, J. / Herrman, D. et al. | 1990
- 119
-
Phantoms and Quantities for the Calibration of Personal DosemetersBartlett, D.T. / Dimbylow, P.J. / Francis, T.M. et al. | 1990
- 123
-
Mandatory Type Tests of Solid State Dosimetry Systems as an Appropriate Aid to Quality Assurance in Individual MonitoringBöhm, J. / Ambrosi, P. et al. | 1990
- 127
-
Hand Dose Levels in Chilean Nuclear Medicine LaboratoriesStuardo, E. et al. | 1990
- 131
-
Thermoluminescence Dosimetry of Beta Radiation on the Basis of Several TL Detectors of Usual ThicknessGotlib, V.I. / Grebenschicov, V.L. / Kantorovich, L.N. et al. | 1990
- 135
-
Beta Dosimetry Using Thin TL DetectorsFellinger, J. / Schmidt, P. / Hübner, K. et al. | 1990
- 137
-
Analysis of Beta Radiation Fields in the Fuel CycleBurgkhardt, B. / Piesch, E. / Vilgis, M. et al. | 1990
- 141
-
Individual Dosimetry Using Electret DetectorsDörschel, B. / Prokert, K. / Seifert, H. et al. | 1990
- 145
-
Mixed Field Personnel Dosimetry Using a Nearly Tissue-Equivalent Multi-Element Thermoluminescence DosemeterMoscovitch, M. / Velbeck, K.J. / Bencke, G.M. et al. | 1990
- 149
-
Some Characteristics of the AEOI Neutriran Albedo Neutron Personnel DosemeterSohrabi, M. / Katouzi, M. et al. | 1990
- 153
-
Reading of Personal Neutron Dosemeters on the MIRD PhantomHollnagel, R. / Alberts, W.G. et al. | 1990
- 157
-
The Active Personnel Dosemeter - Apfel Enterprises Superheated Drop DetectorIpe, N.E. / Donahue, R.J. / Busick, D.D. et al. | 1990
- 161
-
TLD Data Acquisition and Analysis System for Neutron Individual MonitoringMauricio, C.L.P. / Becker, P.H.B. / Kasprzykowski, C.F.A. et al. | 1990
- 165
-
Dose Evaluation in Personal TL Dosimetry by a Database Management SystemDiallo, B. / Miklavzic, U. / Mihelic, M. et al. | 1990
- 167
-
Brazilian Fluorite-Based Dosimetric Pellets: History and Post-Use ReviewTrzesniak, P. / Yoshimura, E.M. / Cruz, M.T. et al. | 1990
- 171
-
Performance Analysis of the TNO TLD Individual Monitoring Servicevan Dijk, J.W.E. / Julius, H.W. et al. | 1990
- 175
-
International Mini-Intercomparison Investigating an Under-Response of TLDs Calibration with 137CsMaiello, M.L. / Gulbin, J.F. / de Planque, G. et al. | 1990
- 179
-
Passive Integrating Radon Monitor Using an Electret Ionisation ChamberStadtmann, H. et al. | 1990
- 183
-
Radon Levels Inside Residences in Mexico CityEspinosa, G. / Gammage, R.B. et al. | 1990
- 187
-
Indoor Radon Measurement in Some Regions of AlgeriaDjeffal, S. / Cherouati, D.E. / Djouider, F. et al. | 1990
- 191
-
Environmental Monitoring around Nuclear Installations using TL DosemetersSzabó, P.P. / Fehér, I. / Germán, E. et al. | 1990
- 195
-
TL Dosimetry Using Bricks and Tiles for Measurement of Transient Gamma Ray Dose in Inhabited AreasHaskell, E.H. / Bailiff, I.K. et al. | 1990
- 199
-
Development of a TL Dosemeter to Measure the New ICRU Dose Quantities H'(10) and H'(0.07) in Environmental DosimetryWernli, C. et al. | 1990
- 203
-
Monitoring of Accelerator-Produced Radionuclides in Air using Thermoluminescence DetectorsTuyn, J.W.N. / Féron, M. et al. | 1990
- 207
-
Considerations on the Use of High Resolution Gamma Spectrometry in Environmental MeasurementsUyttenhove, J. / Poffijn, A. et al. | 1990
- 211
-
A Contribution to Thermoluminescence Dosemeter System Optimisation Applied to Environmental Monitoring Around Nuclear Power PlantsDies, X. / Ortega, X. / Rosell, J. et al. | 1990
- 215
-
Environmental Gamma Radiation Monitoring Using TLD at the Tuwaitha Site and other Regions of IraqAbdul Ahad, Y.K. / Ali, H.H. / Abdalla, M.M. et al. | 1990
- 219
-
Environmental Alpha and Gamma SurveySegovia, N. / Gaso, M.I. / Chavez, A. et al. | 1990
- 223
-
Measurements of Radiation Levels by TLD in the Mineral Processing Plant in BangladeshMollah, A.S. / Rahman, M.M. / Molla, M.A.R. et al. | 1990
- 225
-
A TL Technique for On-Plate Measurement of Doses Below 1 MicrograyBenkö, L. et al. | 1990
- 229
-
A Simple Passive Neutron Spectrum Indicator Using CaSO4:Tm Thermoluminescent DetectorsHonda, Y. / Ogawa, Y. / Kimura, Y. et al. | 1990
- 233
-
Modifications Induced in the TLD-100 Trap Distribution During Exposures at Different Ambient TemperaturesDelgado, A. / Gómez Ros, J.M. et al. | 1990
- 237
-
Variation in 3H Concentrations in the Upper Atmosphere over Japan since 1964Kubozoe, T. et al. | 1990
- 241
-
Clinical Application of Solid State DosimetrySvensson, H. / Nette, P. / Zsdanszky, K. et al. | 1990
- 249
-
Air Kerma Intercomparison at 60Co by Solid TL DetectorsToivonen, M. / Järvinen, H. / Campos, L. et al. | 1990
- 253
-
A Multi-Dose System for Quality Assurance in Radiation TherapySchmidt, W.F.O. / Nedelik, A. / Binder, W. et al. | 1990
- 257
-
Application of Li2B4O7 TL Detectors for Control of Inhomogeneity Calculations by Radiotherapy Treatment Planning SystemsKosunen, A. / Järvinen, H. et al. | 1990
- 261
-
New Automatic Fast Reader for Powder or Sintered Pellets used in Medical PhysicsBarthe, J. / Marinello, G. / Pollack, J. et al. | 1990
- 265
-
Photostimulable Luminescence Screens and Their Application in Clinical DosimetryGurvich, A.M. / Mil'shtejn, R.S. / Myakhkova, M.G. et al. | 1990
- 269
-
Experience in LLD During Low and High LET RadiotherapyHaverkamp, U. / Wiezorek, C. / Pötter, R. et al. | 1990
- 271
-
CT Dosimetry Using a TL TechniquePernicka, F. et al. | 1990
- 275
-
Determination of the Dose Distribution of an Ophthalmic 106Ru Irradiator with TLDs and an Eye PhantomBinder, W. / Chiari, A. / Aiginger, H. et al. | 1990
- 279
-
A Fibre-Optic TLD Microprobe for Remote In Vivo Radiotherapy DosimetryJones, S.C. / Hegland, J.E. / Hoffmann, J.M. et al. | 1990
- 283
-
Miniaturised Dose Measuring System Based on an Opto-Fibre Coupled Scintillation ProbeLow, H.G. / Bonatz, W. / Binder, W. et al. | 1990
- 287
-
Dosimetric Characteristics of Alanine-Based ESR Detectors in Electron Beams Used in RadiotherapyOnori, S. / Bartolotta, A. / Caccia, B. et al. | 1990
- 291
-
Ultra High Level Dosimetry by ESR Spectroscopy of Crystalline Quartz and Fused SilicateWieser, A. / Regulla, D.F. et al. | 1990
- 295
-
Uncertainties in Dose Estimation Under Emergency Conditions and ESR Dosimetry with Human TeethNishiwaki, Y. / Shimano, T. et al. | 1990
- 299
-
Dosimetric Characterisation of Ethylene-Propylene Based Insulating MaterialOnori, S. / Baccaro, S. / Caccia, B. et al. | 1990
- 303
-
ESR Sensitivity Comparison of Sugar from Various Sources and Cavity Mode EffectNakajima, T. / Otsuki, T. / Hara, H. et al. | 1990
- 307
-
ESR Accident Dosimetry Using Medicine Tablets Coated with SugarKai, A. / Ikeya amd T. Miki, M. et al. | 1990
- 311
-
Colour Dosemeters for High Level Radiation DosimetrySchönbacher, H. / Coninckx, F. / Miller, A. et al. | 1990
- 315
-
Feasibility of a High Dosemeter with Metallic Colloid Formation in an Ionic CrystalOwaki, S. / Nobugai, K. / Okada, T. et al. | 1990
- 319
-
Thermoluminescent Dust for Identification of Irradiated SpicesGöksu, H.Y. / Regulla, D.F. / Hietel, B. et al. | 1990
- 323
-
Dosimetry of Intense Mixed Radiation FieldsBilan, O.N. / Cherenda, N.G. / Goulo, V.G. et al. | 1990
- 327
-
The Use of LiF for Dosimetry in the Megagray Range and at Elevated Irradiation TemperaturesWaibel, A. / Göksu, H.Y. / Regulla, D.F. et al. | 1990
- 331
-
Thermal and Fast Neutron Detection in a Polyenergetic Field of NeutronsSavvides, E. / Zamani, M. / Charalambous, St. et al. | 1990
- 335
-
Frequency Sweep ESR Spectrometer for Dosimetry and DatingHara, H. / Ikeya, M. / Nakajima, T. et al. | 1990
- 339
-
Automated TLD Systems: What can we Expect from the Market Today?Duftschmid, K.E. / Strachotinsky, C. et al. | 1990
- 345
-
Present State and Future of TLD Laser HeatingBraunlich, P. et al. | 1990
- 353
-
Use of Thermoluminescence Detectors in National Radiation Protection Monitoring ProgrammesKraus, W. / Will, W. / Buchröder, H. et al. | 1990
- 357
-
A Simple Method for Glow Curve Analysis Improving TLD-100 Performance in the Dose Region Below 100 µGyDelgado, A. / Gómez Ros, J.M. et al. | 1990
- 361
-
A TLD System Based on Gas Heating with Linear Time-Temperature ProfileMoscovitch, M. / Szalanczy, A. / Bruml, W.W. et al. | 1990
- 365
-
A New Desktop Laser Heated TLD ReaderBloomsburg, C.D. / Braunlich, P.F. / Hegland, J.E. et al. | 1990
- 369
-
Modern Automatic Readout Systems for Phosphate Glass Dosemeters Using UV Laser ExcitationBurgkhardt, B. / Piesch, E. / Vilgis, M. et al. | 1990
- 373
-
Measurement of Radioactive Contamination with BeO Thin-Film DetectorsLesz, J. et al. | 1990
- 377
-
Measurement of the Energy Response of Superheated Drop Neutron DetectorsSchwartz, R.B. / Hunt, J.B. et al. | 1990
- 381
-
Radiofrequency Detection by Bubble Dosemeter TechnologyOlsen, R.G. et al. | 1990