Medical imaging IV: image formation : 4-6 February 1990, Newport Beach, California (English)
- New search for: Schneider, Roger H.
1990
-
ISBN:
- Conference Proceedings / Print
-
Title:Medical imaging IV: image formation : 4-6 February 1990, Newport Beach, California
-
Contributors:
-
Conference:Medical Imaging ; 4 ; 1990 ; Newport Beach, Calif.
-
Published in:
-
Publisher:
- New search for: SPIE
-
Place of publication:Bellingham, Wash., USA
-
Publication date:1990
-
Size:viii, 538 p
-
Remarks:28 cm
ill
Includes bibliographical references and index -
ISBN:
-
Type of media:Conference Proceedings
-
Type of material:Print
-
Language:English
- New search for: 616.07/54
- Further information on Dewey Decimal Classification
-
Keywords:
-
Classification:
DDC: 616.07/54 -
Source:
Table of contents conference proceedings
The tables of contents are generated automatically and are based on the data records of the individual contributions available in the index of the TIB portal. The display of the Tables of Contents may therefore be incomplete.
- 2
-
Volume currents in biomagnetic imagingDallas, William J. et al. | 1990
- 7
-
Acoustically modulated electrical impedance tomographyHebden, Jeremy C. / Kruger, Robert A. et al. | 1990
- 15
-
Real-time volumetric ultrasound imaging systemvon Ramm, Olaf T. / Smith, Stephen W. et al. | 1990
- 23
-
Synthetic aperture echo imaging using a single-element ultrasonic transducerSoumekh, Mehrdad et al. | 1990
- 34
-
Application of parametric spectral estimation to medical ultrasound and magnetic resonance spectroscopyWear, Keith A. / Wagner, Robert F. / Garra, Brian S. / Grossman, Laurence W. / Insana, Michael F. / Myers, Kyle J. / Rajan, Sunder S. et al. | 1990
- 40
-
Quality factors for phase-aberration correction in medical ultrasoundTrahey, Gregg E. / Zhao, Danhua et al. | 1990
- 50
-
Description of a simultaneous emission-transmission CT systemHasegawa, Bruce H. / Gingold, Eric L. / Reilly, Susan M. / Liew, Soo-Chin / Cann, Christopher E. et al. | 1990
- 61
-
Development of a 3-D data acquisition system for human facial imagingMarshall, Stephen J. / Rixon, R. C. / Whiteford, Don N. / Wells, Peter J. / Powell, S. J. et al. | 1990
- 75
-
Pigment pattern and depth-of-invasion analysis of skin lesions for malignant melanoma detectionDhawan, Atam P. / Kini, Prashanth et al. | 1990
- 86
-
Ophthalmic imaging with confocal microscopyMasters, Barry R. / Paddock, Stephen W. et al. | 1990
- 97
-
Microholography applied to biological specimensBianco, Bruno / Tommasi, Tullio et al. | 1990
- 104
-
Video pixel spectrometer for diagnostic imagingOuimette, Donald R. / Nudelman, Sol / Zaccheo, Scott / Spackman, Thomas et al. | 1990
- 117
-
Laser scanning endoscope for diagnostic medicineOuimette, Donald R. / Nudelman, Sol / Spackman, Thomas / Zaccheo, Scott et al. | 1990
- 128
-
Measurement of diffusion and random motion effects with fast magnetic resonance imagingBuxton, Richard B. / Wu, Edward X. et al. | 1990
- 138
-
Analytic solution of eddy currents and its temporal compensation in nuclear magnetic resonance imagingAhn, Chang B. / Cho, Zang-Hee et al. | 1990
- 150
-
Measurement of eddy diffusivity by nuclear magnetic resonance imagingNalcioglu, Orhan / Guo, Q. / Buxton, Richard B. et al. | 1990
- 156
-
Four- and eight-echo diagonal interleaved echo planar scanningKashmar, George C. / Nalcioglu, Orhan et al. | 1990
- 164
-
Object detection and amplitude estimation based on maximum a-posteriori reconstructionsHanson, Kenneth M. et al. | 1990
- 176
-
Comparison of the algebraic reconstruction technique with the maximum entropy reconstruction technique for a variety of detection tasksMyers, Kyle J. / Hanson, Kenneth M. et al. | 1990
- 188
-
Maximum likelihood reconstruction algorithm for magnetic resonance imagingSchaewe, Tim J. / Miller, Michael I. et al. | 1990
- 195
-
Maximum a-posteriori detection and figures of merit for detection under uncertaintyWagner, Robert F. / Myers, Kyle J. / Tapiovaara, Markku J. / Brown, David G. / Burgess, Arthur E. et al. | 1990
- 206
-
Projection and backprojection models, and projection sampling in tomographyGuedon, Jeanpierre V. / Bizais, Yves J. et al. | 1990
- 218
-
Quantitative 2-D dual energy imaging: towards 3-D selective reconstructionPicard, Catherine L. / Trousset, Yves L. / Rougee, Anne / Saint-Felix, Didier M. et al. | 1990
- 229
-
Multiscale cone-beam x-ray reconstructionTrousset, Yves L. / Saint-Felix, Didier M. / Rougee, Anne / Chardenon, Christine et al. | 1990
- 239
-
Tabletop CT system for high-resolution volume imagingHoldsworth, David W. / Drangova, Maria / Schulenburg, Klaus S. / Fenster, Aaron et al. | 1990
- 246
-
Sensitivities for CT imaging of contrast agents in a thorax/myocardium phantomFryar, Joseph / O'Hare, Neil J. / Dowsett, D. J. et al. | 1990
- 255
-
Tabletop CT system for 3-D in-vitro analysis of arterial flow and distensibilityDrangova, Maria / Holdsworth, David W. / Fenster, Aaron et al. | 1990
- 262
-
Conversion noise measurement for front and back x-ray intensifying screensTrauernicht, David P. / Van Metter, Richard L. et al. | 1990
- 271
-
Analysis of the effects of depth dependence of x-ray interactions on the MTF and NPS of radiographic screensVan Metter, Richard L. / Rabbani, Majid et al. | 1990
- 276
-
New correlation method for measuring texture noise in x-ray screensKellogg, Reid E. / Beutel, Jacob et al. | 1990
- 287
-
Laser film digitizer: the next generationIshimitsu, Yoshiyuki / Onuki, Mitsuo / Arai, Kazuyuki et al. | 1990
- 295
-
High-resolution, high-performance radiographic film scannerWhiting, Bruce R. / Muka, Edward / Kocher, Thomas E. / Flynn, Michael J. et al. | 1990
- 308
-
Development of a high-resolution camera tube for medical imagingRao, N. V. et al. | 1990
- 316
-
Scanned-slot digital mammographyMaidment, Andrew D. A. / Yaffe, Martin J. et al. | 1990
- 327
-
Determination of x-ray phosphor scintillation spectraMickish, Daniel J. / Beutel, Jacob et al. | 1990
- 337
-
Improved SPECT via cone-beam collimation, the expectation maximization algorithm, and accurate attenuation correctionWelch, A. / Webb, Stephen E. D. / Flower, M. et al. | 1990
- 350
-
Effect of protective layer on resolution properties of photostimulable phosphor detector for digital radiographic systemNakazawa, Masayuki / Morikawa, Osamu / Nitta, Masaaki / Tsuchino, Hisanori / Shimada, Fumio et al. | 1990
- 364
-
Preliminary image-quality measurements on a digital scanned projection radiography systemFritz, Steven L. / Lee, Ching-Shan R. / Roys, Steven R. et al. | 1990
- 374
-
X-ray imaging with 2048 x 2048 CCD arrayHerron, John M. / Daxon, Eric G. / Gur, David / Good, Walter F. / Maitz, Glenn S. / Miller, Stephen L. et al. | 1990
- 381
-
Lens optical coupling versus fiber optical coupling: the impact on x-ray TV image quality with CCDs and pick-up tubesSklebitz, Hartmut et al. | 1990
- 390
-
Evaluation of basic imaging properties of a new digital chest systemMontner, Steven M. / Xu, Xin-Wei / Tsuzaka, Masatoshi / Doi, Kunio / MacMahon, Heber / Yoshimura, Hitoshi / Sanada, Shigeru / Giger, Maryellen L. / Yin, Fang-Fang et al. | 1990
- 394
-
Effects of a-priori information on detection of simulated lung nodules in digital chest radiographySeeley, George W. / Rehm, Kelly / Dallas, William J. et al. | 1990
- 401
-
Digital video system for on-line portal verificationLeszczynski, Konrad W. / Shalev, Shlomo / Cosby, N. Scott et al. | 1990
- 406
-
Digital methods for reducing radiation exposure during medical fluoroscopyEdmonds, Ernest W. / Rowlands, John A. / Hynes, David M. / Toth, B. D. / Porter, Anthony J. et al. | 1990
- 414
-
Linear analysis of rotationally invariant, radially variant tomographic imaging systemsBaker, John R. / Huesman, Ronald H. / Budinger, Thomas F. et al. | 1990
- 422
-
Real-time sensing of mouth 3-D position and orientationBurdea, Grigore C. / Dunn, Stanley M. / Mallik, Matsumita / Jun, Heesung et al. | 1990
- 430
-
New PRIMICON pick-up tube for multimode x-ray TV camerasCalais, Emmanuel / Joffre, Pascal et al. | 1990
- 437
-
Low-frequency transmission of the chest in an outpatient population: implications for the AMBER imaging systemLemmers, Henri E. A. S. J. / Schultze Kool, Leo J. / van Elburg, H. J. / Van Metter, Richard L. et al. | 1990
- 442
-
Photostimulable phosphor imaging applications in molecular biologyLobick, John / Kimura, James H. / Wood, Nancy et al. | 1990
- 447
-
Mammography phantom utilizing free-response receiver operating characteristic methodologyPfeiffer, Douglas / Chakraborty, Dev P. et al. | 1990
- 458
-
Initial experience with a CCD-based imaging systemPlenkovich, Dinko et al. | 1990
- 462
-
Neural network scatter correction technique for digital radiographyBoone, John M. / Seibert, James A. et al. | 1990
- 472
-
Digital x-ray imaging with two-dimensional charge-coupled device arraysHerron, John M. / Gur, David / Daxon, Eric G. / Good, Walter F. / Shaw, Chris C. / Maitz, Glenn S. / Boyer, Joseph W. et al. | 1990
- 479
-
New method to determine the lower limits in patient exposure: stacked computed radiography image detectorsRoehrig, Hans / Ovitt, Theron W. / Seeley, George W. / Yocky, David A. / Dallas, William J. et al. | 1990
- 492
-
Use of computed radiography for portal imagingRoehrig, Hans / Lutz, W. / Barnea, Gideon / Pond, Gerald D. / Dallas, William J. et al. | 1990
- 498
-
Direct scatter distribution measurements: comparison to Monte Carlo simulationsSeibert, James A. / Boone, John M. et al. | 1990
- 508
-
Performance analysis of medical x-ray film digitizersYip, Kwok L. / Lubinsky, Anthony R. / Whiting, Bruce R. / Muka, Edward / Kocher, Thomas E. et al. | 1990
- 526
-
Digital and optically filtered clinical colposcopic imagesCraine, Eric R. / Craine, Brian L. et al. | 1990
- 531
-
Improved differentiating filter function for computing line spread functions in MTF calculationsBeutel, Jacob et al. | 1990