Application of optical instrumentation in medicine XI : April 17-20, 1983 Atlanta, Georgia (English)

1983
  • ISBN:
  • Conference Proceedings  /  Print

How to get this document?

Local TIB services

1 Copy

thereof 1 orderable

TIB document delivery Purchase

Table of contents conference proceedings

The tables of contents are generated automatically and are based on the data records of the individual contributions available in the index of the TIB portal. The display of the Tables of Contents may therefore be incomplete.

2
Benefit/Risk Of Mammographic Screening
Feig, Stephen A. | 1983
15
National Council on Radiation Protection and Measurements (NCRP) Scientific Committee 72-Radiation Protection in Clinical Mammography: A Progress Report
Rothenberg, Lawrence N. | 1983
23
Quality Assurance in a National Breast Screening Study
Yaffe, Martin J. / Mawdsley, Gordon E. / Nishikawa, Robert M. | 1983
31
The Rationale and Efficacy of Applying Multiple Imaging Techniques for Breast Examination: X-Ray Mammography and Ultrasound Visualization
Kelly-Fry, Elizabeth | 1983
37
Absorbed Dose And Image Quality In Xeromammography
Fatouros, P. P. / Goodman, H. / Rao, G. U. / Beachley, M. C. / Jani, S. K. / Bourland, D. | 1983
42
Effects of kVp Variation And X-Ray Tube Filtration On The Mammographic Examination
Malik, S. / Masterson, M. E. .. / Hunt, M. | 1983
51
Sonographic Detectability Of Breast Calcifications
Sickles, Edward A. | 1983
54
Signal-To-Noise Ratio, Dynamic Range And Contrast Sensitivity Of Radiographic Imaging Systems
Schwenker, Ronald P. | 1983
60
Variations In Task And The Ideal Observer
Hanson, Kenneth M. | 1983
68
An Empirical Investigation Of Variability In Contrast-Detail Diagram Measurements
Loo, Leh-Nien D. / Doi, Kunio / Ishida, Masamitsu / Metz, Charles E. / Chan, Heang-Ping / Higashida, Yoshiharu / Kodera, Yoshie | 1983
77
A Method For Estimating X-Ray Scatter Spectra
Moore, William E. | 1983
80
Cardiovascular Cine Film Quality
Scheid, Carl C. | 1983
88
Effect Of System Temporal Response In Radiological Video Imaging
Rowlands, J. A. / Hynes, D. M. / Harris, R. / Edmonds, E. W. / Baranoski, D. | 1983
97
The Photographic Effect Of Long Term Persistency Of Radiographic Screens
Bollen, Romain | 1983
102
Optimal Dose Utilization With Variable X-Ray Intensity In Digital Radiography
Parker, Dennis L. / Clayton, Paul D. / Tarbox, Lawrence R. / VonBehren, Patrick L. | 1983
111
Spatial Frequency Filtering In Digital Subtraction Angiography (DSA) By Real-Time Digital Video Convolution
Dobbins, J. T. / Van Lysel, M. S. / Hasegawa, B. H. / Peppler, W. W. / Mistretta, C. A. | 1983
122
A Study Of The Potential For Digital Radiographic Data Acquisition For Radiation Therapy Treatment Planning
Edwards, M. / Keller, J. / Hobson, G. | 1983
128
Comparison Of Imaging Characteristic Of Digital Subtraction Angiography Utilizing Geometrical Magnification And Electro-Optical Magnification
Lin, Pei-Jan P. / Mintzer, Richard A. | 1983
136
Performance Evaluation And Quality Assurance Of Digital Fluoroscopy Imaging Systems
Houk, Theodore L. / Mun, Seong K. | 1983
140
Fluoroscopic Image Quality Requirements For Coronary Angioplasty
Scheid, Carl C. | 1983
145
The Status Of Quality Assurance For Computed Tomography Systems
McCrohan, J. L. / Showalter, C. K. / Burkhart, R. L. / Shuman, F. G. D. | 1983
157
Quality Assurance For Computed Tomography - Correlation With System Performance
Jacobson, Donald R. | 1983
166
Short Exposure Time Characteristics Of X-Ray Generators
Horn, Bruce A. / Luk, Kim C. / Thomasson, David M. / Finney, Charles E. | 1983
172
Dynamic Flow Phantoms For Digital Radiography (DR) and Nuclear Magnetic Resonance (NMR)
Cahill, P. T. / Kneeland, J. B. / Knowles, R. J. R. / Peterson, M. / Saddekni, S. / Sos, T. | 1983
175
Description Of A Digital Tomosynthesis (DTS) System
Murry, Robert C. / Maravilla, Kenneth R. | 1983
184
The Effect of Photon Transport on the Performance of Electronic Imaging Detectors
Flynn, M. J. / Wilderman, S. / Mulvaney, J. | 1983
192
An Investigation of Digital Mammographic Imaging
Nishikawa, Robert M. / Yaffe, Martin J. | 1983
201
Dual Energy Mammographic Imaging
Johns, Paul C. / Drost, Dick J. / Yaffe, Martin J. .. / Fenster, Aaron | 1983
212
Digital Radiography Systems
Vizy, Kalman N. | 1983
215
Single Slit Digital Radiography: Some Practical Considerations
Tesic, M. M. .. / Sones, R. A. / Morgan, D. R. | 1983
222
A System for Digital Videodensitometry
Johnson, G. Allan / Danieley, Ned / Suddarth, Steven / Dunnick, N. Reed | 1983
228
Technical Alternatives In Nuclear Magnetic Resonance (NMR) Imaging
Hart, H. R. / Bottomley, P. A. / Edelstein, W. A. / Karr, S. G. / Leue, W. M. / Mueller, O. M. / Redington, R. W. / Schenck, J. F. / Smith, L. S. / Vatis, D. | 1983
235
Performance Specifications of a 0.15 Tesla Medical Magnetic Resonance Unit
Pavlicek, William / Meaney, Thomas F. | 1983
245
Architectural Considerations in a Medical Magnetic Resonance Imaging Facility
Pavlicek, William / Meaney, Thomas F. .. / Cutting, Malcolm / Budish, Irving I. .. | 1983
256
The Dependence Of Nuclear Magnetic Resonance (NMR) Image Contrast On Intrinsic And Operator-Selectable Parameters
Wehrli, F. W. / MacFall, J. R. / Glover, G. H. | 1983
265
Magnetic Resonance Imaging Using Permanent Magnets
Masi, C. G. | 1983
271
Biexponential T2Discrimination of Normal, Benign, and Malignant Human Breast Tissue
McSweeney, Marjorie B. / Small, William C. / Goldstein, J. H. / Sewell, C. Whitaker / Powell, R. Waldo | 1983
282
Selective Exposure Radiography Using Digitally-Formed X-Ray Beam Attenuators
Hasegawa, B. H. .. / Dobbins, J. T. / Peppler, W. W. / Kudva, B. V. / Melbye, K. M. / Van Lysel, M . S. .. / Lee, C. S. / Naimuddin, S. / Lancaster, J. C. .. / Mistretta, C. A. .. | 1983
289
Electrical Impedance Imaging Of The Body With Nonlinear Reconstruction
Kim, Yongmin / Tompkins, Willis J. / Webster, John G. | 1983
297
Radioluminescent Imaging: Factors Affecting Total Light Output
Zweig, Gilbert / Zweig, David A. | 1983
305
Computer Information System For Nuclear Medicine
Cahill, P. T. / Knowles, R. J. .. .. / Tsen, O. | 1983
Feedback