Dose Equivalent Response of Personal Neutron Dosemeters as a Function of Angle (Englisch)

in Radiation protection dosimetry ; 70 , 1-4 ; 165-
Radiation protection dosimetry

The measured and calculated dose equivalent response as a function of angle has been examined for an albedo-type thermoluminescence dosemeter (TLD) that was exposed to unmoderated and D20-moderated 252Cf neutron sources while mounted on a 40 x 40 x 15 cm3 polymethylmethacrylate phantom. The dosemeter used in this study is similar to many neutron personal dosemeters currently in use. The detailed construction of the dosemeter was modelled, and the dose equivalent response was calculated, using the MCNP code. Good agreement was found between the measured and calculated values of the relative dose equivalent angular response for the TLD albedo dosemeter. The relative dose equivalent angular response was also compared with the values of directional and personal dose equivalent as a function of angle published by Siebert and Schuhmacher.

Wie erhalte ich diesen Titel?
Download
Kommerziell Vergütung an den Verlag: 31,74 € Grundgebühr: 4,00 € Gesamtpreis: 35,74 €
Akademisch Vergütung an den Verlag: 31,74 € Grundgebühr: 2,00 € Gesamtpreis: 33,74 €

Dokumentinformationen


Inhaltsverzeichnis – Band 70, Ausgabe 1-4

Zeige alle Jahrgänge und Ausgaben

Die Inhaltsverzeichnisse werden automatisch erzeugt und basieren auf den im Index des TIB-Portals verfügbaren Nachweisen der enthaltenen Aufsätze. Die Anzeige der Jahrgänge kann aufgrund fehlender Aufsatznachweise unvollständig oder lückenhaft sein, obwohl die Zeitschrift komplett in der TIB verfügbar ist.

0-xv
Editorial - Eighth Symposium on Neutron Dosimetry
Menzel, H.G. / Chartier, J.L. / Jahr, R. / Rannou, A. | 1997
1
Nuclear Data Needs for Neutron Therapy and Radiation Protection
Chadwick, M.B. / DeLuca, P.M. / Haight, R.C. | 1997
13
Kerma Measurements in Polyenergetic Neutron Fields
Newhauser, W.D. / Schrewe, U.J. / Brede, H.J. / Matzke, M. / DeLuca, P.M. | 1997
17
Comparison of Various Dose Quantities in Tissue and Tissue Substitutes at Neutron Energies Between 20 MeV and 100 MeV
Schrewe, U.J. / Alberts, W.G. / Newhauser, W.D. / Brede, H.J. / DeLuca, P.M. | 1997
21
Double Differential Cross Section Measurements of the (n,px), (n,dx), (n,tx) and (n,ax) Reactions on 12C:Kerma Determination at Energies between 30 and 75 MeV
Slypen, I. / Benck, S. / Corcalciuc, V. / Meulders, J.-P. | 1997
21
Double Differential Cross Section Measurements of the (n,px), (n,dx), (n,tx) and (n,alphax) Reactions on 12C: Kerma Determination at Energies Between 30 and 75 MeV
Slypen, I. / Benck, S. / Corcalciuc, V. / Meulders, J.P. | 1997
21
Double Differential Cross Section Measurements of the (n,px), (n,dx), (n,tx) and (n,�x) Reactions on ^1^2C:Kerma Determination at Energies between 30 and 75 MeV
Slypen, I. / Benck, S. / Corcalciuc, V. / Meulders, J.-P. | 1997
27
Relative Neutron Sensitivity of Tissue-Equivalent Ionisation Chambers in an Epithermal Neutron Beam for Boron Neutron Capture Therapy
Jansen, J.T.M. / Raaijmakers, C.P.J. / Mijnheer, B.J. / Zoetelief, J. | 1997
33
W Values in Propane-Based Tissue-Equivalent Gas
Bronic, I.K. | 1997
37
W Values of Protons Slowed Down in Molecular Hydrogen
Grosswendt, B. / Willems, G. / Baek, W.Y. | 1997
47
Stopping Powers of He and Ar Gases for 50-200 keV 3He+ Ions
Fukuda, A. | 1997
49
Calculations of the Giant-Dipole-Resonance Photoneutrons Using a Coupled EGS4-Morse Code
Liu, J.C. / Nelson, W.R. / Kase, K.R. / Mao, X.S. | 1997
55
Calculation of Radial Dose Distributions for Heavy Ions by a New Analytical Approach
Chen, J. / Kellerer, A.M. | 1997
59
Electronic Neutron Dosemeters: History and State of the Art
Barthe, J. / Bordy, J.M. / Lahaye, T. | 1997
67
Needs and Performance Requirements for Neutron Monitoring in the Nuclear Power Industry
Hirning, C.R. / Waker, A.J. | 1997
73
Single Diode Detector for Individual Neutron Dosimetry using a Pulse Shape Analysis
Bordy, J.M. / Lahaye, T. / Landre, F. / Hoflack, C. / Lequin, S. / Barthe, J. | 1997
79
Advanced Detectors for Active Neutron Dosemeters
Vareille, J.C. / Barelaud, B. / Barthe, J. / Bordy, J.M. / Curzio, G. / d'Errico, F. / Decossas, J.L. / Fernandez-Moreno, F. / Lahaye, T. / Luguera, E. et al. | 1997
83
Efficiencies of an SSNTD and an Electronic Neutron Dosemeter with the Same (n,�)(n,p) Converter
Savvidis, E. / Zamani, M. | 1997
83
Efficiencies of an SSNTD and an Electronic Neutron Dosemeter with the Same (n,a)(n,p) Converter
Savvidis, E. / Zamani, M. | 1997
83
Efficiencies of an SSNTD and an Electronic Neutron Dosemeter with the Same (n,alpha) (n,p) Converter
Savvidis, E. / Zamani, M. | 1997
87
Separation of the Neutron Signal from the Gamma Component in (n-gamma) Fields Using Differential Pulse Analysis Techniques with a Double Silicon Diode
Fernández, F. / Luguera, E. / Domingo, C. / Baixeras, C. | 1997
87
Separation of the Neutron Signal from the Gamma Component in (n-g) Fields using Differential Pulse Analysis Techniques with a Double Silicon Diode
Fernández, F. / Luguera, E. / Domingo, C. / Baixeras, C. | 1997
93
Study of a Moderator Type Electronic Neutron Dosemeter for Personal Dosimetry
Moiseev, T. | 1997
97
Feasibility Study of an Individual Electronic Neutron Dosemeter
Luszik-Bhadra, M. / Alberts, W.G. / Dietz, E. / Siebert, B.R.L. | 1997
103
Advances in Superheated Drop (Bubble) Detector Techniques
d'Errico, F. / Alberts, W.G. / Matzke, M. | 1997
109
Superheated Emulsions: Neutronics and Thermodynamics
d'Errico, F. / Apfel, R.E. / Curzio, G. / Dietz, E. / Egger, E. / Gualdrini, G.F. / Guldbakke, S. / Nath, R. / Siebert, B.R.L. | 1997
113
Fast Discrimination of Neutrons from (�,n) and Fission Sources
Apfel, R. E. / D'Errico, F. / Martin, J. D. | 1997
113
Fast Discrimination of Neutrons from (a,n) and Fission Sources
Apfel, R.E. / d'Errico, F. / Martin, J.D. | 1997
113
Fast Discrimination of Neutrons from (alpha,n) and Fission Sources
Apfel, R.E. / d'Errico, F. / Martin, J.D. | 1997
117
Methodological Studies on the Optimisation of Multi-Element Dosemeters in Neutron Fields
Alberts, W.G. / Dörschel, B. / Siebert, B.R.L. | 1997
121
Future Developments in the NRPB PADC Neutron Personal Monitoring Service
Tanner, R.J. / Bartlett, D.T. / Hager, L.G. / Lavelle, J. | 1997
127
The Present Status of Etched Track Neutron Dosimetry in Europe and the Contribution of CENDOS and EURADOS
Harvey, J.R. / Tanner, R.J. / Alberts, W.G / Bartlett, D.T. / Piesch, E.K.A. / Schraube, H. | 1997
133
Etched Track Size Distributions Induced by Broad Neutron Spectra in PADC
Jakes, J. / Voigt, J. / Schraube, H. | 1997
139
Analysis of Acceptance Testing Data for More than 800 Sheets of CR39 Plastic Assessed for the DRPS Approved Neutron Dosimetry Service
Jackson, M. / French, A.P. | 1997
143
Polycarbonate Track Detectors with a Flat Energy Response for the Measurement of High Energy Neutrons at Accelerators and Airflight Altitudes
Józefowicz, K. / Burgkhardt, B. / Vilgis, M. / Piesch, E. | 1997
149
An Automated Neutron Dosimetry System Based on the Chemical Etch of CR39
Harvey, J.R. / French, A.P. / Jackson, M. / Renouf, M.C. / Weeks, A.R. | 1997
153
Angular Response to Neutrons of the Electrochemically Etched CR-39 with Different Radiators
Bednár, J. / Turek, K. / Spurný, F. | 1997
157
A Personal Neutron Dosimetry System Based on Etched Track and Automatic Readout by Autoscan 60
Fiechtner, A. / Gmür, K. / Wernli, C. | 1997
161
Ten Years On: The NRPB PADC Neutron Personal Monitoring Service
Bartlett, D.T. / Steele, J.D. / Tanner, R.J. / Gilvin, P.J. / Shaw, P.V. / Lavelle, J. | 1997
165
Dose Equivalent Response of Personal Neutron Dosemeters as a Function of Angle
Tanner, J.E. / McDonald, J.C. / Stewart, R.D. / Wernli, C. | 1997
169
Measurement of Neutron Dose on Fusion Reactor Shield Using TLD-300 Phosphors
Angelone, M. / Batistoni, P. / Esposito, A. / Martone, M. / Pelliccioni, M. / Pillon, M. / Rado, V. | 1997
169
Measurement of Neutron Dose on a Fusion Reactor Shield using TLD-300 Phosphors
Angelone, M. / Batistoni, P. / Esposito, A. / Martone, M. / Pelliccioni, M. / Pillon, M. / Rado, V. | 1997
175
TL Dosimetry in High Fluxes of Thermal Neutrons Using Variously Doped LiF and KMgF3
Gambarini, G. / Martini, M. / Scacco, A. / Raffaglio, C. / Sichirollo, A.E. | 1997
181
Evaluation of Individual Neutron Dosimetry by a Working Group in the French Nuclear Industry
Rannou, A. / Clech, A. / Devita, A. / Dollo, R. / Pescayre, G. | 1997
187
Neutron Dosimetry at the Reactor Facility VENUS
Deboodt, P. / Vermeersch, F. / Vanhavere, F. / Minsart, G. | 1997
193
Some Examples of Industrial Uses of Neutron Sources
Szabo, J.L. / Boutaine, J.L. | 1997
197
TEPC Performance in the CANDU Workplace
Waker, A.J. / Szornel, K. / Nunes, J. | 1997
203
Microdosimetric Investigations in Realistic Fields
Bottollier-Depois, J.F. / Plawinski, L. / Spurný, F. / Mazal, A. | 1997
207
Neutron Energy Deposition Spectra at Simulated Diameters Down to 50 nm
Anachkova, E. / Kellerer, A.M. / Roos, H. | 1997
211
Review of Recent Achievements of Recombination Methods
Golnik, N. | 1997
215
Recombination Index of Radiation Quality of Medical High Energy Neutron Beams
Golnik, N. / Cherevatenko, E.P. / Serov, A.Y. / Shvidkij, S.V. / Sychev, B.S. / Zielczynski, M. | 1997
219
Concept of a Neutron Dosemeter Based on a Recoil Particle Track Chamber
Titt, U. / Breskin, A. / Chechik, R. / Dangendorf, V. / Grosswendt, B. / Schuhmacher, H. | 1997
225
Workplace Radiation Field Analysis
Klein, H. | 1997
235
Neutron Dose Equivalent Rates Calculated from Measured Neutron Angular and Energy Distributions in Working Environments
Drake, P. / Bartlett, D.T. | 1997
241
A Database of Neutron Spectra, Instrument Response Functions, and Dosimetric Conversion Factors for Radiation Protection Applications
Naismith, O.F. / Siebert, B.R.L. | 1997
247
Neutron Fluence Measurements with a Liquid Scintillator
Binns, P.J. / Hough, J.H. / Simpson, B.R.S. | 1997
251
Neutron and Photon Spectra and Dose Rates Around a Shielding Cask Placed in a Salt Mine to Simulate a Nuclear Waste Package
Knauf, K. / Alevra, A.V. / Wittstock, J. / Engelmann, H.J. / Khamis, M. / Niehues, N. | 1997
255
Response of Neutron Dosemeters in Radiation Protection Environments: An Investigation of Techniques to Improve Estimates of Dose Equivalent
Naismith, O.F. / Siebert, B.R.L. / Thomas, D.J. | 1997
261
Directional Information on Neutron Fields
Matzke, M. / Kluge, H. / Luszik-Bhadra, M. | 1997
265
Application of Neutron Spectrometry in the DRPS Neutron Dosimetry Service
Barlow, K. / Jackson, M. / French, A. / Harvey, J.R. | 1997
269
A New Approach to Low-Level Monitoring in Mixed Radiation Fields
Pszona, S. | 1997
273
ROSPEC - A Simple Reliable High Resolution Neutron Spectrometer
Ing, H. / Clifford, T. / McLean, T. / Webb, W. / Cousins, T. / Dhermain, J. | 1997
279
Specification of Bonner Sphere Systems for Neutron Spectrometry
Kralik, M. / Aroua, A. / Grecescu, M. / Mares, V. / Novotný, T. / Schraube, H. / Wiegel, B. | 1997
285
Improved Neutron Spectrometer Based on Bonner Spheres
Aroua, A. / Grecescu, M. / Prêtre, S. / Valley, J.F. | 1997
291
High Energy Response Functions of Bonner Spectrometers
Sannikov, A.V. / Mares, V. / Schraube, H. | 1997
295
Measurements with the PTB 'C' Bonner Sphere Spectrometer in the PSI Villigen 55 MeV Neutron Field for Spectrometry and Calibration Purposes
Alevra, A.V. / Schrewe, U.J. | 1997
295
Measurements with the PTB ^1C^1 Bonner Sphere Spectrometer in the PSI Villigen 55 MeV Neutron Field for Spectrometry and Calibration Purposes
Alevra, A. V. / Schrewe, U. J. | 1997
299
Calibration of a Neutron Spectrometer in the Energy Range 144 keV to 14.8 MeV with ISO Energies
Rosenstock, W. / Köble, T. / Kruziniski, G. / Jaunich, G. | 1997
305
Recent Developments in the Specification and Achievement of Realistic Neutron Calibration Fields
Chartier, J.L. / Jansky, B. / Kluge, H. / Schraube, H. / Wiegel, B. | 1997
313
Results of a Large Scale Neutron Spectrometry and Dosimetry Comparison Exercise at the Cadarache Moderator Assembly
Thomas, D.J. / Chartier, J.L. / Klein, H. / Naismith, O.F. / Posny, F. / Taylor, G.C. | 1997
323
Current Status of an ISO Working Document on Reference Radiations: Characteristics and Methods of Production of Simulated Practical Neutron Fields
McDonald, J.C. / Alberts, W.G. / Bartlett, D.T. / Chartier, J.L. / Eisenhauer, C.M. / Schraube, H. / Schwartz, R.B. / Thomas, D.J. | 1997
327
Scattered Neutron Reference Fields Produced by Radionuclide Sources
Kluge, H. / Alevra, A.V. / Jetzke, S. / Knauf, K. / Matzke, M. / Weise, K. / Wittstock, J. | 1997
331
Advances in Realistic Neutron Spectra: Progress in Fluence Monitoring of the DD Reaction
Paul, D. / Pelcot, G. / Itié, C. | 1997
331
Advances in Realistic Neutron Spectra: Progress in Fluence Monitoring of DD Reaction
Paul, D. / Pelcot, G. / Itié, C. | 1997
337
GRENF - The GSF Realistic Neutron Field Facility
Schraube, H. / Hietel, B. / Jakes, J. / Mares, V. / Schraube, G. / Weitzenegger, E. | 1997
341
Dosimetric Characteristics of the IHEP Neutron Reference Fields
Alekseev, A.G. / Kharlampiev, S.A. | 1997
345
Silene, A Tool for Neutron Dosimetry
Tournier, B. / Barbry, F. / Verrey, B. | 1997
349
Determination of Neutron Room Scattering Corrections in RCL's Calibration Facility at KAERI
Yoon, S.C. / Chang, S.Y. / Kim, J.S. / Kim, J.L. | 1997
353
Tests of Instruments for Neutron and Gamma Ray Measurements at Several Radionuclide Neutron Sources
Spurný, F. / Votocková, I. / Bottollier-Depois, J-F. / Kurkdjian, J. / Paul, D. | 1997
357
A New Expression for Determination of Fluences from a Spherical Moderator Neutron Source for the Calibration of Spherical Neutron Measuring Devices
Khoshnoodi, M. / Sohrabi, M. | 1997
361
The Neutron Fluence and H^*(10) Response of the New LB 6411 Rein Counter
Burgkhardt, B. / Fieg, G. / Klett, A. / Plewnia, A. / Siebert, B. R. L. | 1997
361
The Neutron Fluence and H*(10) Response of the New LB 6411 REM Counter
Burgkhardt, B. / Fieg, G. / Klett, A. / Plewnia, A. / Siebert, B.R.L. | 1997
365
A Spherical Neutron Counter with an Extended Energy Response for Dosimetry
Toyokawa, H. / Uritani, A. / Mori, C. / Takeda, N. / Kudo, K. | 1997
371
Computational Dosimetry
Siebert, B.R.L. / Thomas, R.H. | 1997
379
On the Conservativity of Hp(10)
Leuthold, G. / Mares, V. / Schraube, H. | 1997
383
Ambient Dose Equivalent Conversion Factors for High Energy Neutrons Based on the ICRP 60 Recommendations
Sannikov, A.V. / Savitskaya, E.N. | 1997
387
Calculation of the Personal Dose Equivalent, Hp(10), for Neutrons in the MIRD Phantom
Hollnagel, R.A. | 1997
391
Organ Doses and Dose Equivalents for Neutrons above 20 MeV
Mares, V. / Leuthold, G. / Schraube, H. | 1997
395
Dosimetry for Occupational Exposure to Cosmic Radiation
Bartlett, D.T. / McAulay, I.R. / Schrewe, U.J. / Schnuer, K. / Menzel, H.G. / Bottollier-Depois, J-F. / Dietze, G. / Gmür, K. / Grillmaier, R.E. / Heinrich, W. et al. | 1997
405
The Cosmic Ray Induced Neutron Spectrum at the Summit of the Zugspitze (2963m)
Schraube, H. / Jakes, J. / Sannikov, A. / Weitzenegger, E. / Roesler, S / Heinrich, W. | 1997
409
Experimental Approach to the Exposure of Aircrew to Cosmic Radiation
Spurný, F. | 1997
413
Results of Dosimetric Measurements in Space Missions
Reitz, G. / Beaujean, R. / Kopp, J. / Leicher, M. / Stauch, K. / Heilmann, C. | 1997
419
Dosimetry of High Energy Neutrons and Protons by 209Bi Fission
Cross, W.G. / Tommasino, L. | 1997
425
Measurements of Neutron Spectra at the Stanford Linear Accelerator Center
Vylet, V. / Liu, J.C. / Rokni, S.H. / Thai, L-X. | 1997
429
Shielding Measurements for a Proton Therapy Beam of 200 MeV: Preliminary Results
Mazal, A. / Gall, K. / Bottollier-Depois, J.F. / Michaud, S. / Delacroix, D. / Fracas, P. / Clapier, F. / Delacroix, S. / Nauraye, C. / Ferrand, R. et al. | 1997
437
Neutron Measurements Around a High-Energy Lead Ion Beam at CERN
Aroua, A. / Buchillier, T. / Grecescu, M. / Höfert, M. | 1997
441
Secondary Dose Exposures During 200 MeV Proton Therapy
Binns, P.J. / Hough, J.H. | 1997
445
Criticality Accident Dosimetry: An International Intercomparison at the Silene Reactor
Médioni, R. / Delafield, H.J. | 1997
455
Biological Dosimetry after a Criticality Accident
Fatôme, M. / Agay, D. / Martin, S. / Mestries, J.C. / Multon, E. | 1997
461
Characterisation of a Clothing Material for Gamma Dosimetry in Mixed Neutron-Gamma Fields
Benabdesselam, M. / Iacconi, P. / Lapraz, D. / Serbat, A. / Dhermain, J. / Laugier, J. | 1997
467
Chromosome Aberrations Scoring for Biological Dosimetry in a Criticality Accident
Voisin, P. / Lloyd, D. / Edwards, A. | 1997
471
Fast Neutron Radiotherapy: The University of Washington Experience and Potential Use of Concomitant Boost with Boron Neutron Capture
Stelzer, K.J. / Lindsley, K.L. / Cho, P.S. / Laramore, G.E. / Griffin, T.W. | 1997
477
Energy Spectra in the NAC Proton Therapy Beam
Brooks, F.D. / Jones, D.T.L. / Bowley, C.C. / Symons, J.E. / Buffler, A. / Allie, M.S. | 1997
481
Calculated Fluence Spectra at Neutron Therapy Facilities
Ross, M.A. / DeLuca, P.M. / Jones, D.T.L. / Lennox, A. / Maughan, R.L. | 1997
485
Biophysical Investigations of Therapeutic Proton Beams
Becker, R. / Bienen, J. / Carl, U. / Cloth, P. / Dellert, M. / Drüke, V. / Eyrich, W. / Filges, D. / Fritsch, M. / Hauffe, J. et al. | 1997
493
Microdosimetric Studies on the Orsay Proton Synchrocyclotron at 73 and 200 MeV
Cosgrove, V.P. / Delacroix, S. / Green, S. / Mazal amd M.C. Scott, A. | 1997
497
Comparison of HETC and PTRAN with Phantom Measurement Data
Becker, R. / Bienen, J. / Cloth, P. / Dellert, M. / Drüke, V. / Eyrich, W. / Filges, D. / Fritsch, M. / Hauffe, J. / Heinrichs, U. et al. | 1997
501
Investigation of Efficiency of Thermoluminescence Detectors for Particle Therapy Beams
Bilski, P. / Budzanowski, M. / Hoffmann, W. / Molokanov, A. / Olko, P. / Waligorski, M.P.R. | 1997
505
Measurement of the Heat Defect in Water and A-150 Plastic for High Energy Protons, Deuterons and a Particles
Brede, H.J. / Hecker, O. / Hollnagel, R. | 1997
505
Measurement of the Heat Defect in Water and A-150 Plastic for High Energy Protons, Deuterons and � Particles
Brede, H. J. / Hecker, O. / Hollnagel, R. | 1997
505
Measurement of the Heat Defect in Water and A-150 Plastic for High-Energy Protons, Deuterons, and alpha-Particles
Brede, H.J. / Hecker, O. / Hollnagel, R. | 1997
509
3D Treatment Planning for 14 MeV Neutrons
Schmidt, R. / Frenzel, T. / Krüll, A. / Lüdemann, L. / Matzen, T. | 1997
513
Evaluation of the Dose Algorithm Based on the Scatter Model Applied for Neutron Therapy Treatment Planning
Yudelev, M. / Maughan, R.L. / He, T. / Ragan, D.P. | 1997
517
Specification of Absorbed Dose and Radiation Quality in Heavy Particle Therapy (A Review)
Wambersie, A. / Menzel, H.G. | 1997
517
Specification of Absorbed Dose and Radiation Quality in Heavy Particle Therapy
Wambersie, A. / Menzel, H. G. | 1997
529
A Unified System of Radiation Bio-Effectiveness and its Consequences in Practical Applications
Watt, D.E. | 1997
529
A Unified System of Radiation Bio-Effectiveness and its Consequences in Practical Application
Watt, D.E. | 1997
537
Risk Scaling Factors from Inactivation to Chromosome Aberrations, Mutations and Oncogenic Transformations in Mammalian Cells
Alkharam, A.S. / Watt, D.E. | 1997
541
Nanodosimetric Results and Radiotherapy Beams: A Clinical Application?
Lindborg, L. / Grindborg, J.E. | 1997
547
BNCT: Status and Dosimetry Requirements
Gahbauer, R. / Gupta, N. / Blue, T. / Goodman, J. / Grecula, J. / Soloway, A.H. / Wambersie, A. | 1997
555
Microdosimetric Analysis of Absorbed Dose in Boron Neutron Capture Therapy
Kota, C. / Maughan, R.L. | 1997
559
Characterisation of an Accelerator-Based Neutron Source for BNCT of Explanted Livers
Agosteo, S. / Colautti, P. / Corrado, M.G. / d'Errico, F. / Matzke, M. / Monti, S. / Silari, M. / Tinti, R. | 1997
567
Reactor Based Epithermal Neutron Beam Enhancement at Rez
Marek, M. / Burian, J. / Rataj, J. / Polák, J. / Spurný, F. | 1997
571
Fricke-Infused Agarose Gel Phantoms for NMR Dosimetry in Boron Neutron Capture Therapy and Proton Therapy
Gambarini, G. / Birattari, C. / Monti, D. / Fumagalli, M.L. / Vai, A. / Salvadori, P. / Facchielli, L. / Sichirollo, A.E. | 1997
Eightth Symposium on Neutron Dosimetry
Menzel, H.G. / Chartier, J.L. / Jahr, R. / Rannou, A. | 1997

Ähnliche Titel