RADIATION PROTECTION DOSIMETRY
Die Inhaltsverzeichnisse werden automatisch erzeugt und basieren auf den im Index des TIB-Portals verfügbaren Einzelnachweisen der enthaltenen Beiträge. Die Anzeige der Inhaltsverzeichnisse kann daher unvollständig oder lückenhaft sein.
Inhaltsverzeichnis
- 1
-
INTERNATIONAL CONFERENCE ON INDIVIDUAL MONITORING OF IONISING RADIATIONVanhavere, Filip / On behalf of the Organising Committee, et al. | 2016
- 4
-
A SHORT HISTORY AND CRITICAL REVIEW OF INDIVIDUAL MONITORINGWernli, Christian et al. | 2016
- 8
-
TECHNICAL RECOMMENDATIONS FOR MONITORING INDIVIDUALS FOR OCCUPATIONAL INTAKES OF RADIONUCLIDESEtherington, G. / Bérard, P. / Blanchardon, E. et al. | 2016
- 13
-
EVOLUTION OF THE IEC AND EN STANDARDS FOR INDIVIDUAL MONITORING OF IONISING RADIATIONVoytchev, M. / Behrens, R. / Ambrosi, P. et al. | 2016
- 17
-
EURADOS-IDEAS GUIDELINES (VERSION 2) FOR THE ESTIMATION OF COMMITTED DOSES FROM INCORPORATION MONITORING DATACastellani, C. M. / Marsh, J. W. / Hurtgen, C. et al. | 2016
- 21
-
FIRST EURADOS INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS FOR MEDICAL APPLICATIONSClairand, I. / Ginjaume, M. / Vanhavere, F. et al. | 2016
- 27
-
2240 IRRADIATED PERSONAL DOSEMETERS FOR THE IC2014 EURADOS INTERCOMPARISON AT SEIBERSDORFHranitzky, C. et al. | 2016
- 31
-
THE CHALLENGE OF CIEMAT INTERNAL DOSIMETRY SERVICE FOR ACCREDITATION ACCORDING TO ISO/IEC 17025 STANDARD, FOR IN VIVO AND IN VITRO MONITORING AND DOSE ASSESSMENT OF INTERNAL EXPOSURESLopez, M. A. / Martin, R. / Hernandez, C. et al. | 2016
- 35
-
CORRECTIONS ASSOCIATED WITH ON-PHANTOM CALIBRATIONS OF NEUTRON PERSONAL DOSEMETERSHawkes, N. P. / Thomas, D. J. / Taylor, G. C. et al. | 2016
- 39
-
RETROSPECTIVE METHOD VALIDATION AND UNCERTAINTY ESTIMATION FOR ACTINIDES DETERMINATION IN EXCRETA BY ALPHA SPECTROMETRYHernández, C. / Sierra, I. et al. | 2016
- 45
-
AIR KERMA TO Hp(3) CONVERSION COEFFICIENTS FOR IEC 61267 RQR X-RAY RADIATION QUALITIES: APPLICATION TO DOSE MONITORING OF THE LENS OF THE EYE IN MEDICAL DIAGNOSTICSPrincipi, S. / Guardiola, C. / Duch, M. A. et al. | 2016
- 49
-
SECOND LATIN AMERICAN INTERCOMPARISON ON INTERNAL DOSE ASSESSMENTRojo, A. / Puerta, N. / Gossio, S. et al. | 2016
- 54
-
PRACTICAL METROLOGICAL ASPECTS OF NEUTRON PERSONAL DOSIMETRYKrálík, M. / Vykydal, Z. et al. | 2016
- 58
-
AN INTERLABORATORY COMPARISON ON THE DETERMINATION OF 241AM, 244CM AND 252CF IN URINEGerstmann, Udo C. / Taubner, Kerstin / Hartmann, Martina et al. | 2016
- 63
-
DEVELOPMENT OF SIMULATED WORKPLACE FIELDS AT KRISS FOR PERFORMANCE TEST OF NEUTRON PERSONAL DOSEMETERSKim, Jungho / Park, Hyeonseo / Kim, Yunho et al. | 2016
- 67
-
IAEA INTERCOMPARISON EXERCISES OF THYROID MEASUREMENT: PERFORMANCE OF LATIN AMERICAN AND CARIBBEAN LABORATORIESDantas, B. M. / Dantas, A. L. A. / Cruz-Suarez, R. et al. | 2016
- 70
-
CIEMAT EXTERNAL DOSIMETRY SERVICE: ISO/IEC 17025 ACCREDITATION AND 3 Y OF OPERATIONAL EXPERIENCE AS AN ACCREDITED LABORATORYRomero, A. M. / Rodríguez, R. / López, J. L. et al. | 2016
- 74
-
UNCERTAINTY EVALUATION FOR MULTIDETECTOR PASSIVE DOSEMETERS USING A TWO-STAGE MEASUREMENT MODEL AND THE MONTE CARLO METHODvan Dijk, J. W. E. et al. | 2016
- 78
-
EURADOS IC2012N: FURTHER INFORMATION DERIVED FROM AN EURADOS INTERNATIONAL COMPARISON OF NEUTRON PERSONAL DOSEMETERSChevallier, M.-A. / Fantuzzi, E. / Cruz-Suarez, R. et al. | 2016
- 82
-
EURADOS INTERCOMPARISONS IN EXTERNAL RADIATION DOSIMETRY: SIMILARITIES AND DIFFERENCES AMONG EXERCISES FOR WHOLE-BODY PHOTON, WHOLE-BODY NEUTRON, EXTREMITY, EYE-LENS AND PASSIVE AREA DOSEMETERSRomero, Ana M. / Grimbergen, Tom / McWhan, Andrew et al. | 2016
- 86
-
THE RESULTS OF THE EURADOS INTERCOMPARISON IC2014 FOR WHOLE-BODY DOSEMETERS IN PHOTON FIELDSStadtmann, H. / Grimbergen, T. W. M. / Figel, M. et al. | 2016
- 90
-
EURADOS PROGRAMME OF INTERCOMPARISONS FOR INDIVIDUAL MONITORING SERVICES: SEVEN YEARS OF DEVELOPMENT AND FUTURE PLANSGrimbergen, T. / Figel, M. / McWhan, A. et al. | 2016
- 95
-
A PRACTICAL APPROACH TO PERFORM THE ISOTROPY TEST FOR EXTREMITY DOSEMETERSGultresa, J. / Llansana, J. / Roig, M. et al. | 2016
- 100
-
A SURVEY ON THE ACCURACY OF WHOLE-BODY COUNTERS OPERATED IN FUKUSHIMA AFTER THE NUCLEAR DISASTERNakano, T. / Kim, E. / Tani, K. et al. | 2016
- 103
-
SECONDARY STANDARD CALIBRATION, MEASUREMENT AND IRRADIATION CAPABILITIES OF THE INDIVIDUAL MONITORING SERVICE AT THE HELMHOLTZ ZENTRUM MÜNCHEN: ASPECTS OF UNCERTAINTY AND AUTOMATIONGreiter, M. B. / Denk, J. / Hoedlmoser, H. et al. | 2016
- 108
-
USE OF A SIMPLE THERMALISED NEUTRON FIELD FOR QUALITY ACCEPTANCE OF WHOLE BODY TLDSGilvin, P. J. / Baker, S. T. / Eakins, J. S. et al. | 2016
- 113
-
EURADOS INTERCOMPARISONS ON WHOLE-BODY DOSEMETERS FOR PHOTONS FROM 2008 TO 2014Figel, Markus / Stadtmann, Hannes / Grimbergen, Tom W. M. et al. | 2016
- 117
-
CURRENT STATUS OF INDIVIDUAL DOSIMETRIC MONITORING IN UKRAINEChumak, V. / Deniachenko, N. / Makarovska, O. et al. | 2016
- 122
-
INVESTIGATION OF THE EXTENDED RANGE REM-COUNTER SMARTREM-LINUS IN REFERENCE AND WORKPLACE FIELDS EXPECTED AROUND HIGH-ENERGY ACCELERATORSHohmann, Eike / Trovati, S. / Strauch, U. et al. | 2016
- 127
-
CHARACTERIZATION OF AN ACTIVE DOSEMETER ACCORDING TO IEC 61526:2010Cardoso, J. / Santos, J.A.M. / Santos, L. et al. | 2016
- 132
-
DOSIMETRIC QUALITY ASSURANCE INTERPRETED FOR ISO 17025 IN PUBLIC HEALTH ENGLAND'S PERSONAL DOSIMETRY SERVICEGilvin, P. J. / Gibbens, N. J. / Baker, S. T. et al. | 2016
- 136
-
COMPARISON METHODOLOGIES FOR CALIBRATION OF HP(10) PERSONAL DOSEMETERS USING ISO 4037 AND ISO 29661 STANDARDSCardoso, J. / Santos, L. / Carvalhal, G. et al. | 2016
- 141
-
SIMPLIFIED PRACTICAL TEST METHOD FOR PORTABLE DOSE METERS USING SEVERAL SEALED RADIOACTIVE SOURCESMikamoto, Takahiro / Yamada, Takahiro / Kurosawa, Tadahiro et al. | 2016
- 145
-
EDEL: ENEA DOSEMETER FOR EYE LENSFerrari, Paolo / Mariotti, Francesca / Campani, Lorenzo et al. | 2016
- 150
-
DOSIMETRIC PROPERTIES OF THE NEW TLD ALBEDO NEUTRON DOSEMETER AWST-TL-GD 04Haninger, T. / Henniger, J. et al. | 2016
- 154
-
STABILITY OF THE NEUTRON DOSE DETERMINATION ALGORITHM FOR PERSONAL NEUTRON DOSEMETERS AT DIFFERENT RADON GAS EXPOSURESMayer, Sabine / Boschung, Markus / Butterweck, Gernot et al. | 2016
- 158
-
GENERALISATION OF RADIATOR DESIGN TECHNIQUES FOR PERSONAL NEUTRON DOSEMETERS BY UNFOLDING METHODOda, K. / Nakayama, T. / Umetani, K. et al. | 2016
- 162
-
COMPARISON OF DIFFERENT PADC MATERIALS AND ETCHING CONDITIONS FOR FAST NEUTRON DOSIMETRYAssenmacher, F. / Boschung, M. / Hohmann, E. et al. | 2016
- 168
-
A STUDY ON THE UNCERTAINTY FOR THE ROUTINE DOSIMETRY SERVICE AT THE LEBANESE ATOMIC ENERGY COMMISSION USING HARSHAW 8814 DOSEMETERSRizk, C. / Vanhavere, F. et al. | 2016
- 173
-
CALIBRATION OF THERMOLUMINESCENCE AND FILM DOSEMETERS FOR SKIN DOSES FROM HIGH-ACTIVITY MICROPARTICLESEakins, J. S. / Hager, L. G. / Tanner, R. J. et al. | 2016
- 177
-
FADING EFFECT OF LIF:MG,TI AND LIF:MG,CU,P EXT-RAD AND WHOLE-BODY DETECTORSPereira, J. / Pereira, M. F. / Rangel, S. et al. | 2016
- 181
-
DOSE MEASUREMENTS TO THE LENS IN NUCLEAR MEDICINE AND IN FLUOROSCOPY-GUIDED INTERVENTIONAL PROCEDURES: ANALYSIS OF THE RESULTS AND ASSESSMENT OF THE EFFECTIVENESS OF PROTECTIVE EYEWEAR ANTI-XSarti, G. / Busca, F. / Carpano, L. et al. | 2016
- 187
-
PLASTIC SCINTILLATOR FOR RADIATION DOSIMETRYKim, Yewon / Yoo, Hyunjun / Kim, Chankyu et al. | 2016
- 191
-
A THIN-LAYER LIF THERMOLUMINESCENCE DOSEMETER SYSTEM WITH FAST READOUT FOR THE USE IN PERSONAL DOSIMETRY SERVICESWalbersloh, J. / Busch, F. et al. | 2016
- 195
-
DESIGN DEVELOPMENT OF A PASSIVE NEUTRON DOSEMETER FOR THE USE AT HIGH-ENERGY ACCELERATORSSokolov, Alexey / Fehrenbacher, Georg / Radon, Torsten et al. | 2016
- 199
-
INFLUENCE OF DIFFERENT TYPES OF PHANTOMS ON THE CALIBRATION OF DOSEMETERS FOR EYE LENS DOSIMETRYYoshitomi, H. / Kowatari, M. et al. | 2016
- 204
-
APPLICATION OF PTTL METHOD FOR DOSE REASSESSMENT IN EXTREMITY DOSIMETRYSas-Bieniarz, A. / Budzanowski, M. / Bubak, A. et al. | 2016
- 208
-
ENERGY AND ANGULAR DEPENDENCE OF RADIOPHOTOLUMINESCENT GLASS DOSEMETERS FOR EYE LENS DOSIMETRYSilva, E. H. / Knezevic, Z. / Struelens, L. et al. | 2016
- 213
-
CHARACTERIZATION OF A THIN SILICON SENSOR FOR ACTIVE NEUTRON PERSONAL DOSEMETERSTakada, M. / Nunomiya, T. / Nakamura, T. et al. | 2016
- 218
-
RELATIVE DISSOLUTION RATES OF RADIOACTIVE MATERIALS USED AT AWEMiller, T. J. / Bingham, D. / Cockerill, R. et al. | 2016
- 221
-
PERSONALISED BODY COUNTER CALIBRATION USING ANTHROPOMETRIC PARAMETERSPölz, S. / Breustedt, B. et al. | 2016
- 225
-
CALIBRATION OF A WHOLE BODY COUNTER FOR 241Am WITH THE LLNL CHEST PHANTOMPázmándi, T. / Andrási, A. / Fehér, I. et al. | 2016
- 231
-
EFFICIENCY STUDY OF A LEGE DETECTOR SYSTEM FOR THE ASSESSMENT OF 241AM IN SKULL AT CIEMAT WHOLE BODY COUNTERPérez López, B. / Navarro, J. F. / López Ponte, M. A. et al. | 2016
- 237
-
DEVELOPMENT OF A RAPID PROCEDURE TO ANALYSE PU, AM AND 90SR IN EMERGENCY URINE BIOASSAY IN CIEMAT BIOELIMINATION LABORATORY: METHOD VALIDATION BY EMERGENCY BIOASSAY INTERCOMPARISON EXERCISESSierra, I. / Hernández, C. et al. | 2016
- 242
-
TESTING THE IDEAS GUIDELINES AS APPLIED TO PLUTONIUM INTAKESBull, Richard / Roberts, Gareth et al. | 2016
- 247
-
SILICON DIODE AS AN ALPHA PARTICLE DETECTOR AND SPECTROMETER FOR DIRECT FIELD MEASUREMENTSÖren, Ünal / Nilsson, Jonas / Herrnsdorf, Lars et al. | 2016
- 252
-
APPLICATION OF AN IMAGING PLATE FOR EVALUATING THE UNCERTAINTY IN DIRECT ORGAN MEASUREMENTS DUE TO VARIATION IN DETECTOR LOCATIONKurihara, Osamu / Kanai, Katsuta / Hirota, Masahiro et al. | 2016
- 256
-
ASSESSMENT OF EYE LENS DOSES IN INTERVENTIONAL RADIOLOGY: A SIMULATION IN LABORATORY CONDITIONSCemusová, Z. / Ekendahl, D. / Judas, L. et al. | 2016
- 261
-
DOSE MEASUREMENTS IN THE STRAY FIELD OF A GE OPTIMA CT660Zutz, H. / Alikhani, B. et al. | 2016
- 265
-
A SOLUTION FOR NEUTRON PERSONAL DOSIMETRY IN THE ABSENCE OF WORKPLACE SPECTROMETRYHajek, M. / Cruz Suárez, R. et al. | 2016
- 269
-
PROPERTIES OF THE BEOSL DOSIMETRY SYSTEM IN THE FRAMEWORK OF A LARGE-SCALE PERSONAL MONITORING SERVICEHaninger, T. / Hödlmoser, H. / Figel, M. et al. | 2016
- 274
-
RADIATION PROTECTION CABIN FOR CATHETER-DIRECTED LIVER INTERVENTIONS: OPERATOR DOSE ASSESSMENTMaleux, Geert / Bergans, Niki / Bosmans, Hilde et al. | 2016
- 279
-
OCCUPATIONAL DOSE ASSESSMENT IN INTERVENTIONAL CARDIOLOGY IN SERBIAKaljevic, J. / Ciraj-Bjelac, O. / Stankovic, J. et al. | 2016
- 284
-
FIELD CORRECTION FACTORS FOR PERSONAL NEUTRON DOSEMETERSLuszik-Bhadra, M. et al. | 2016
- 288
-
ENHANCED RADIOACTIVE CONTENT OF 'BALANCE BRACELETSTsroya, S. / Pelled, O. / Abraham, A. et al. | 2016
- 292
-
HAND DOSE EVALUATION OF OCCUPATIONALLY EXPOSED STAFF IN NUCLEAR MEDICINEKaljevic, Jelica / Stankovic, Koviljka / Stankovic, Jelena et al. | 2016
- 297
-
EYE LENS DOSES IN NUCLEAR MEDICINE: A MULTICENTRIC STUDY IN BELGIUM AND POLANDDabin, Jérémie / Kopec, Renata / Struelens, Lara et al. | 2016
- 302
-
HOW DO HOSPITAL STERILISATION PROCEDURES AFFECT THE RESPONSE OF PERSONAL EXTREMITY RINGS AND OF EYE LENS TL DOSEMETERS?Kopec, Renata / Bubak, Anna / Budzanowski, Maciej et al. | 2016
- 307
-
A REVIEW OF TWO METHODS USED IN THE USA TO ASSESS HE DURING FLUOROSCOPIC-BASED RADIOLOGYYoder, R. Craig / Salasky, Mark R. et al. | 2016
- 311
-
OCCUPATIONAL EXPOSURE TO RADON IN DIFFERENT KINDS OF NON-URANIUM MINESFan, D. / Zhuo, W. / Zhang, Y. et al. | 2016
- 315
-
THREE-YEAR RETENTION OF RADIOACTIVE CAESIUM IN THE BODY OF TEPCO WORKERS INVOLVED IN THE FUKUSHIMA DAIICHI NUCLEAR POWER STATION ACCIDENTNakano, T. / Tani, K. / Kim, E. et al. | 2016
- 318
-
RESPONSE OF DOSEMETERS IN FIELDS GENERATED BY LASER-ACCELERATED PROTONSOlsovcová, V. / Versaci, R. / Ambrozová, I. et al. | 2016
- 322
-
DOSE TO RADIOLOGICAL TECHNOLOGISTS FROM INDUCED RADIONUCLIDES IN CARBON ION RADIOTHERAPYYonai, S. / Spano, V. et al. | 2016
- 326
-
A SINGLE-EXPOSURE, MULTIDETECTOR NEUTRON SPECTROMETER FOR WORKPLACE MONITORINGBedogni, R. / Bortot, D. / Buonomo, B. et al. | 2016
- 331
-
RADON AND PROGENY SOURCED DOSE ASSESSMENT OF SPA EMPLOYEES IN BALNEOLOGICAL SITESUzun, Sefa Kemal / Demiröz, Isık et al. | 2016
- 336
-
SECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTREDe Saint-Hubert, M. / Saldarriaga Vargas, C. / Van Hoey, O. et al. | 2016
- 342
-
ENVIRONMENTAL MONITORING WITH PASSIVE DETECTORS AT CTN IN PORTUGALPereira, M. F. / Pereira, J. / Rangel, S. et al. | 2016
- 346
-
ENVIRONMENTAL DOSIMETRY WITH THE BeOSL PERSONAL DOSEMETERJahn, A. / Sommer, M. / Henniger, J. et al. | 2016
- 350
-
MCNP SIMULATION OF THE HP(10) ENERGY RESPONSE OF A BRAZILIAN TLD ALBEDO NEUTRON INDIVIDUAL DOSEMETER, FROM THERMAL TO 20 MeVFreitas, B. M. / Martins, M. M. / Pereira, W. W. et al. | 2016
- 354
-
MONTE CARLO SIMULATION OF THE BREMSSTRAHLUNG RADIATION FOR THE MEASUREMENT OF AN INTERNAL CONTAMINATION WITH PURE-BETA EMITTERS IN VIVOFantínová, K. / Fojtík, P. / Malátová, I. et al. | 2016
- 359
-
CRUCIAL PARAMETERS FOR PROPER SIMULATION OF THE DETECTOR USED IN IN VIVO MEASUREMENTSVrba, T. et al. | 2016
- 364
-
NUMERICAL ASSESSMENT OF 131I DEPOSITED IN THYROID FOR NON-STANDARD SITUATIONSMoraleda, M. / Gómez-Ros, J. M. et al. | 2016
- 369
-
CREATION OF FEMALE COMPUTATIONAL PHANTOMS FOR CALIBRATION OF LUNG COUNTERSLombardo, Pasquale Alessandro / Lebacq, Anne Laure / Vanhavere, Filip et al. | 2016
- 373
-
NUMERICAL SIMULATION OF DIRECT MEASUREMENT TO DETERMINE THYROID 131I CONTENT OF TWO TEPCO WORKERS CONSIDERING INDIVIDUAL TISSUE THICKNESSTani, Kotaro / Kurihara, Osamu / Kim, Eunjoo et al. | 2016
- 377
-
CALCULATION OF GAMMA SPECTRA IN A PLASTIC SCINTILLATOR FOR ENERGY CALIBRATIONAND DOSE COMPUTATIONKim, Chankyu / Yoo, Hyunjun / Kim, Yewon et al. | 2016
- 382
-
STUDY OF DOSES TO HIPPOCAMPUS OF INTERVENTIONAL CARDIOLOGISTS AND THEIR IMPLICATION FOR DOSIMETRIC MONITORINGChumak, V. / Morgun, A. / Bakhanova, E. et al. | 2016
- 387
-
INDIVIDUAL DOSIMETRY IN DISPOSAL REPOSITORY OF HEAT-GENERATING NUCLEAR WASTEPang, Bo / Saurí Suárez, Héctor / Becker, Frank et al. | 2016
- 393
-
OPTIMISATION OF SCATTER RADIATION TO STAFF DURING CT-FLUOROSCOPY: MONTE CARLO STUDIESGyekye, P. K. / Becker, F. / Mensah, S. Y. et al. | 2016
- 398
-
INTEGRATED CIRCUITS FROM MOBILE PHONES AS POSSIBLE EMERGENCY OSL/TL DOSIMETERSSholom, S. / McKeever, S. W. S. et al. | 2016
- 402
-
LESSONS LEARNED FROM THE EURADOS SURVEY ON INDIVIDUAL MONITORING DATA AND INTERNAL DOSE ASSESSMENTS OF FOREIGNERS EXPOSED IN JAPAN FOLLOWING THE FUKUSHIMA DAIICHI NPP ACCIDENTLopez, M. A. / Fojtik, P. / Franck, D. et al. | 2016
- 407
-
STUDY OF THE SUITABILITY OF ISRAELI HOUSEHOLD SALT FOR RETROSPECTIVE DOSIMETRYDatz, Hanan / Druzhyna, Sofia / Oster, Leonid et al. | 2016
- 412
-
THE PHE FORTUITOUS DOSIMETRY CAPABILITY BASED ON OPTICALLY STIMULATED LUMINESCENCE OF MOBILE PHONESEakins, J. S. / Hager, L. G. / Kouroukla, E. et al. | 2016
- 416
-
DETERMINATION OF THE INTERNAL EXPOSURE OF GREEK CITIZENS RETURNING FROM JAPAN IMMEDIATELY AFTER THE FUKUSHIMA ACCIDENTPotiriadis, C. / Kehagia, K. / Kolovou, M. et al. | 2016
- 420
-
INTERNAL DOSES OF THREE PERSONS STAYING 110 KM SOUTH OF THE FUKUSHIMA DAIICHI NUCLEAR POWER STATION DURING THE ARRIVAL OF RADIOACTIVE PLUMES BASED ON DIRECT MEASUREMENTSKurihara, Osamu / Nakagawa, Takahiro / Takada, Chie et al. | 2016
- 425
-
ESTABLISHMENT OF A NATIONAL DOSE REGISTER AND A DOSIMETRY SERVICE APPROVAL SYSTEM IN IRELANDSmith, V. / Pollard, D. / Fennell, S. et al. | 2016
- 425
-
ESTABLISHMENT OF A NATIONAL DOSE REGISTER AND A DOSIMETRY SERVICE APPROVAL SYSTEM IN IRELAND: Table 1Smith, V et al. | 2016
- 429
-
NATIONAL DOSE REGISTER IN FRANCE WITHIN THE NATIONAL INFORMATION SYSTEM SISERIScanff, P. / Crescini, D. / Roy, H. et al. | 2016
- 433
-
OCCUPATIONAL EXPOSURE TO EXTERNAL RADIATION IN SWITZERLANDMayer, S. / Baechler, S. / Damet, J. et al. | 2016
- 437
-
INVESTIGATIONS CONDUCTED AMONG FINNISH RADIATION WORKERS IN 2004-13 AND THEIR EFFECT ON THE RECORDED INDIVIDUAL DOSESKiuru, A. / Lehtinen, M. / Alén, R. et al. | 2016
- 442
-
EXPERIENCES IN DEVELOPING A NATIONAL DOSE REGISTER IN FINLAND AND MERGING IT WITH THE OVERALL SUPERVISORY DATA SYSTEMLehtinen, M. / Alén, R. / Kiuru, A. et al. | 2016
- 446
-
THE EURADOS-KIT TRAINING COURSE ON MONTE CARLO METHODS FOR THE CALIBRATION OF BODY COUNTERSBreustedt, B. / Broggio, D. / Gomez-Ros, J. M. et al. | 2016
- 451
-
INTERNATIONAL CONFERENCE ON INDIVIDUAL MONITORING OF IONISING RADIATION: LIST OF PARTICIPANTS| 2016
- 457
-
AUTHOR INDEX| 2016