Bitte wählen Sie ihr Lieferland und ihre Kundengruppe
The Tokamak Fusion Test Reactor will be installed at the Princeton Plasma Physics Laboratory facility. This is a major step to reach the goal of fusion power using toroidal magnetic fields for plasma confinement. A major part of this test reactor will be four neutral beam injection systems. These systems will inject 20 MW of 120 kV neutral deuterium atoms into the plasma for 0.5 seconds. In order to achieve the required power input to the plasma, several systems are required within the neutral beam line. These are the source, neutralizer, ion deflection magnet, calorimeter and retraction system, ion dump, cryopumps and vacuum enclosure. All of these systems have constraints imposed which increase the complexity of their designs. Since all systems must operate in a tritium environment, remote handling capabilities must be incorporated into the design. An overview is presented of the Lawrence Livermore Laboratory/Lawrence Berkeley Laboratory Neutral Beam Injection System design. Specifications for the machine and a general description of the total system are presented. (ERA citation 03:025533)