Bitte wählen Sie ihr Lieferland und ihre Kundengruppe
In this report a synopsis of the German carbide program is presented. The program comprises the irradiation of about 100 carbide pins equipped with pelletted fuel. Most of these fuel pins were He-bonded, the sodium bonding concept taken as a back-up solution. The main design parameters such as smear and pellet density, gap size, pin diameter and wall thickness as well as the irradiation conditions were varied mostly within wide ranges. Based on a compilation of relevant pin parameters, irradiation conditions, and the results of various irradiation experiments conclusions on the optimum ranges of the main design parameters are drawn. Furthermore, some important aspects of fuel pin behaviour are discussed based on quantitative results from post irradiation examinations. (ERA citation 08:057148)