Variability analysis of SAR from 20 MHz to 2.4 GHz for different adult and child models using finite-difference time-domain (Englisch)
Nationallizenz
- Neue Suche nach: Conil, E
- Neue Suche nach: Hadjem, A
- Neue Suche nach: Lacroux, F
- Neue Suche nach: Wong, M F
- Neue Suche nach: Wiart, J
- Neue Suche nach: Conil, E
- Neue Suche nach: Hadjem, A
- Neue Suche nach: Lacroux, F
- Neue Suche nach: Wong, M F
- Neue Suche nach: Wiart, J
In:
Physics in Medicine & Biology
;
53
, 6
;
1511-1525
;
2008
- Aufsatz (Zeitschrift) / Elektronische Ressource
-
Titel:Variability analysis of SAR from 20 MHz to 2.4 GHz for different adult and child models using finite-difference time-domain
-
Beteiligte:Conil, E ( Autor:in ) / Hadjem, A ( Autor:in ) / Lacroux, F ( Autor:in ) / Wong, M F ( Autor:in ) / Wiart, J ( Autor:in )
-
Erschienen in:Physics in Medicine & Biology ; 53, 6 ; 1511-1525
-
Erscheinungsdatum:21.03.2008
-
ISSN:
-
DOI:
-
Medientyp:Aufsatz (Zeitschrift)
-
Format:Elektronische Ressource
-
Sprache:Englisch
-
Datenquelle:
Inhaltsverzeichnis – Band 53, Ausgabe 6
Zeige alle Jahrgänge und Ausgaben
Die Inhaltsverzeichnisse werden automatisch erzeugt und basieren auf den im Index des TIB-Portals verfügbaren Einzelnachweisen der enthaltenen Beiträge. Die Anzeige der Inhaltsverzeichnisse kann daher unvollständig oder lückenhaft sein.
- 1511
-
Variability analysis of SAR from 20 MHz to 2.4 GHz for different adult and child models using finite-difference time-domainConil, E / Hadjem, A / Lacroux, F / Wong, M F / Wiart, J et al. | 2008
- 1527
-
Benchmarking EGSnrc in the kilovoltage energy range against experimental measurements of charged particle backscatter coefficientsAli, E S M / Rogers, D W O et al. | 2008
- 1545
-
Proton dose calculation based on in-air fluence measurementsSchaffner, Barbara et al. | 2008
- 1563
-
Methods for prostate stabilization during transperineal LDR brachytherapyPodder, Tarun / Sherman, Jason / Rubens, Deborah / Messing, Edward / Strang, John / Ng, Wan-Sing / Yu, Yan et al. | 2008
- 1581
-
Monte Carlo calculations and measurements of absorbed dose per monitor unit for the treatment of uveal melanoma with proton therapyKoch, Nicholas / Newhauser, Wayne D / Titt, Uwe / Gombos, Dan / Coombes, Kevin / Starkschall, George et al. | 2008
- 1595
-
Monte Carlo calculations of beam quality correction factors kQ for electron dosimetry with a parallel-plate Roos chamberZink, K / Wulff, J et al. | 2008
- 1609
-
Standardization of magnetocardiography in nonhuman primatesSeki, Yusuke / Muneyuki, Kenta / Kandori, Akihiko / Tsukada, Keiji / Terao, Keiji / Ageyama, Naohide et al. | 2008
- 1619
-
Fast temperature optimization of multi-source hyperthermia applicators with reduced-order modeling of ‘virtual sources’Cheng, Kung-Shan / Stakhursky, Vadim / Craciunescu, Oana I / Stauffer, Paul / Dewhirst, Mark / Das, Shiva K et al. | 2008
- 1637
-
An apparent threshold dose response in ferrous xylenol-orange gel dosimeters when scanned with a yellow light sourceBabic, Steven / Battista, Jerry / Jordan, Kevin et al. | 2008
- 1651
-
A multiple model approach to respiratory motion prediction for real-time IGRTPutra, Devi / Haas, Olivier C L / Mills, John A / Burnham, Keith J et al. | 2008
- 1665
-
Role of the parameters involved in the plan optimization based on the generalized equivalent uniform dose and radiobiological implicationsWidesott, L / Strigari, L / Pressello, M C / Benassi, M / Landoni, V et al. | 2008
- 1677
-
Equivalent dose and effective dose from stray radiation during passively scattered proton radiotherapy for prostate cancerFontenot, Jonas / Taddei, Phillip / Zheng, Yuanshui / Mirkovic, Dragan / Jordan, Thomas / Newhauser, Wayne et al. | 2008
- 1689
-
Worst case optimization: a method to account for uncertainties in the optimization of intensity modulated proton therapyPflugfelder, D / Wilkens, J J / Oelfke, U et al. | 2008
- 1701
-
Time dependence of electrical bioimpedance on porcine liver and kidney under a 50 Hz ac currentSpottorno, J / Multigner, M / Rivero, G / Álvarez, L / Venta, J de la / Santos, M et al. | 2008
- 1715
-
Image-guided radiosurgery for spinal tumors: methods, accuracy and patient intrafraction motionAgazaryan, Nzhde / Tenn, Steve E / Desalles, Antonio A F / Selch, Michael T et al. | 2008
- 1729
-
Comparison between the lateral penumbra of a collimated double-scattered beam and uncollimated scanning beam in proton radiotherapySafai, Sairos / Bortfeld, Thomas / Engelsman, Martijn et al. | 2008
- 1751
-
Automatic segmentation of thoracic and pelvic CT images for radiotherapy planning using implicit anatomic knowledge and organ-specific segmentation strategiesHaas, B / Coradi, T / Scholz, M / Kunz, P / Huber, M / Oppitz, U / André, L / Lengkeek, V / Huyskens, D / van Esch, A et al. | 2008
- 1773
-
Harmonic motion imaging for focused ultrasound (HMIFU): a fully integrated technique for sonication and monitoring of thermal ablation in tissuesMaleke, C / Konofagou, E E et al. | 2008
- 1795
-
FDTD computation of human eye exposure to ultra-wideband electromagnetic pulsesSimicevic, Neven et al. | 2008
- N81
-
Experimental results on fast 2D-encoded magnetic particle imagingGleich, B / Weizenecker, J / Borgert, J et al. | 2008
- N85
-
Comparison of air kerma standards of LNE–LNHB and NPL for 192Ir HDR brachytherapy sources: EUROMET project no 814Douysset, Guilhem / Sander, Thorsten / Gouriou, Jean / Nutbrown, Rebecca et al. | 2008
-
NOTE: Experimental results on fast 2D-encoded magnetic particle imagingGleich, B. et al. | 2008
-
NOTE: Comparison of air kerma standards of LNE–LNHB and NPL for 192Ir HDR brachytherapy sources: EUROMET project no 814Douysset, Guilhem et al. | 2008