An inexpensive automatic two-detector lung scanner (Englisch)
Nationallizenz
- Neue Suche nach: H Dawson
- Neue Suche nach: R B Douglas
- Neue Suche nach: D Pavia
- Neue Suche nach: E Reeves
- Neue Suche nach: M D Short
- Neue Suche nach: M L Thomson
- Neue Suche nach: H Dawson
- Neue Suche nach: R B Douglas
- Neue Suche nach: D Pavia
- Neue Suche nach: E Reeves
- Neue Suche nach: M D Short
- Neue Suche nach: M L Thomson
In:
Physics in Medicine & Biology
;
16
, 4
;
691-692
;
1971
- Aufsatz (Zeitschrift) / Elektronische Ressource
-
Titel:An inexpensive automatic two-detector lung scanner
-
Beteiligte:H Dawson ( Autor:in ) / R B Douglas ( Autor:in ) / D Pavia ( Autor:in ) / E Reeves ( Autor:in ) / M D Short ( Autor:in ) / M L Thomson ( Autor:in )
-
Erschienen in:Physics in Medicine & Biology ; 16, 4 ; 691-692
-
Erscheinungsdatum:01.10.1971
-
ISSN:
-
DOI:
-
Medientyp:Aufsatz (Zeitschrift)
-
Format:Elektronische Ressource
-
Sprache:Englisch
-
Datenquelle:
Inhaltsverzeichnis – Band 16, Ausgabe 4
Zeige alle Jahrgänge und Ausgaben
Die Inhaltsverzeichnisse werden automatisch erzeugt und basieren auf den im Index des TIB-Portals verfügbaren Einzelnachweisen der enthaltenen Beiträge. Die Anzeige der Inhaltsverzeichnisse kann daher unvollständig oder lückenhaft sein.
- 577
-
A new approach to the determination of anatomical cross-sections of the body by Compton scattering of gamma-raysF T Farmer / M P Collins et al. | 1971
- 587
-
129Cs production via the 127I(α,2n) 129Cs reaction and its preparation as a radiopharmaceuticalV J Sodd / J W Blue / K L Scholz et al. | 1971
- 599
-
Dosimetry of π--mesons using silicon detectors and plastic scintillatorsM R Raju / E Lampo / S B Curtis / C Richman et al. | 1971
- 611
-
The operation of proportional counters at low pressures for microdensityP J Campion et al. | 1971
- 617
-
Calculated effective atomic number and Kerma values for tissue-equivalent and dosimetry materialsC A Jayachandran et al. | 1971
- 625
-
Quantitative profile scanning for the measurement of organ radioactivityP Tothill / J M Galt et al. | 1971
- 635
-
Data processing of radioisotope images for optimum smoothingD C Barber / J R Mallard et al. | 1971
- 645
-
Skin temperature distributions over veins and tumoursJ W Draper / J W Boag et al. | 1971
- 655
-
Description of anomalous e.s.r. signals from normal rabbit liverJ M S Hutchison / M A Foster / J R Mallard et al. | 1971
- 663
-
The non-linearities of arterial blood flowW E Bodley et al. | 1971
- 673
-
The external action potential of a nerve or muscle fibre in an extended mediumR E Pattle et al. | 1971
- 687
-
Simplified liquid scintillation countingD E Barber et al. | 1971
- 691
-
An inexpensive automatic two-detector lung scannerH Dawson / R B Douglas / D Pavia / E Reeves / M D Short / M L Thomson et al. | 1971
- 693
-
The 1971 Meeting of ICRPF D Sowby et al. | 1971
- 695
-
Sensitization in LiF:Teflon dosemetersG S Linsley / E W Mason et al. | 1971
- 698
-
Dosimetry of 129Cs and 131CsR T Anger Jr / V J Sodd et al. | 1971
- 700
-
Electrons scattered from supervoltage photon beamsP R Purser et al. | 1971
- 701
-
Standardization of Nuclear Medicine InstrumentationT D Cradduck et al. | 1971
- 704
-
An off-line computer interface for a rectilinear scannerD J Dowsett / D R Ritchie et al. | 1971