Use of micro-CT-based finite element analysis to accurately quantify peri-implant bone strains: a validation in rat tibiae (Englisch)
- Neue Suche nach: Torcasio, Antonia
- Neue Suche nach: Zhang, Xiaolei
- Neue Suche nach: Van Oosterwyck, Hans
- Neue Suche nach: Duyck, Joke
- Neue Suche nach: van Lenthe, G. Harry
- Neue Suche nach: Torcasio, Antonia
- Neue Suche nach: Zhang, Xiaolei
- Neue Suche nach: Van Oosterwyck, Hans
- Neue Suche nach: Duyck, Joke
- Neue Suche nach: van Lenthe, G. Harry
In:
Biomechanics and Modeling in Mechanobiology
;
11
, 5
; 743-750
;
2011
-
ISSN:
- Aufsatz (Zeitschrift) / Print
-
Titel:Use of micro-CT-based finite element analysis to accurately quantify peri-implant bone strains: a validation in rat tibiae
-
Beteiligte:Torcasio, Antonia ( Autor:in ) / Zhang, Xiaolei ( Autor:in ) / Van Oosterwyck, Hans ( Autor:in ) / Duyck, Joke ( Autor:in ) / van Lenthe, G. Harry ( Autor:in )
-
Erschienen in:Biomechanics and Modeling in Mechanobiology ; 11, 5 ; 743-750
-
Verlag:
- Neue Suche nach: Springer-Verlag
- Neue Suche nach: Springer
-
Erscheinungsort:Berlin
-
Erscheinungsdatum:2011
-
ISSN:
-
ZDBID:
-
DOI:
-
Medientyp:Aufsatz (Zeitschrift)
-
Format:Print
-
Sprache:Englisch
- Neue Suche nach: 76.12$jBiomechanik$jBewegungslehre / 44.09$jMedizintechnik / 42.12$jBiophysik / 44.09 / 76.12 / 42.12
- Weitere Informationen zu Basisklassifikation
-
Schlagwörter:
-
Klassifikation:
BKL: 76.12$jBiomechanik$jBewegungslehre / 44.09$jMedizintechnik / 42.12$jBiophysik / 44.09 Medizintechnik / 76.12 Biomechanik, Bewegungslehre / 42.12 Biophysik -
Datenquelle:
Inhaltsverzeichnis – Band 11, Ausgabe 5
Zeige alle Jahrgänge und Ausgaben
Die Inhaltsverzeichnisse werden automatisch erzeugt und basieren auf den im Index des TIB-Portals verfügbaren Einzelnachweisen der enthaltenen Beiträge. Die Anzeige der Inhaltsverzeichnisse kann daher unvollständig oder lückenhaft sein.
- 585
-
Efficient characterization of inhomogeneity in contraction strain patternNazzal, Christina M. / Mulligan, Lawrence J. / Criscione, John C. et al. | 2011
- 595
-
Anisotropic microsphere-based approach to damage in soft fibered tissueSáez, P. / Alastrué, V. / Peña, E. / Doblaré, M. / Martínez, M. A. et al. | 2011
- 609
-
Estimation of tissue contractility from cardiac cine-MRI using a biomechanical heart modelChabiniok, R. / Moireau, P. / Lesault, P.-F. / Rahmouni, A. / Deux, J.-F. / Chapelle, D. et al. | 2011
- 631
-
A comparison of healthy human and swine articular cartilage dynamic indentation mechanicsRonken, S. / Arnold, M. P. / Ardura García, H. / Jeger, A. / Daniels, A. U. / Wirz, D. et al. | 2011
- 641
-
Effects of wall shear stress and its gradient on tumor cell adhesion in curved microvesselsYan, W. W. / Cai, B. / Liu, Y. / Fu, B. M. et al. | 2011
- 655
-
Mechanics of chondrocyte hypertrophyDonkelaar, C. C. / Wilson, W. et al. | 2011
- 665
-
Hypotonic challenge modulates cell volumes differently in the superficial zone of intact articular cartilage and cartilage explantTurunen, Siru M. / Lammi, Mikko J. / Saarakkala, Simo / Koistinen, Arto / Korhonen, Rami K. et al. | 2011
- 677
-
Mathematical model and numerical simulation of the cell growth in scaffoldsJeong, Darae / Yun, Ana / Kim, Junseok et al. | 2011
- 689
-
Insights into interstitial flow, shear stress, and mass transport effects on ECM heterogeneity in bioreactor-cultivated engineered cartilage hydrogelsChen, Tony / Buckley, Mark / Cohen, Itai / Bonassar, Lawrence / Awad, Hani A. et al. | 2011
- 703
-
Mechanical behavior of human embryonic stem cell pellet under unconfined compressionMa, Gang / Petersen, Erik / Leong, Kam W. / Liao, Kin et al. | 2011
- 715
-
Estimation of aneurysm wall stresses created by treatment with a shape memory polymer foam deviceHwang, Wonjun / Volk, Brent L. / Akberali, Farida / Singhal, Pooja / Criscione, John C. / Maitland, Duncan J. et al. | 2011
- 731
-
Time-dependent behavior of cartilage surrounding a metal implant for full-thickness cartilage defects of various sizes: a finite element studyManda, Krishnagoud / Eriksson, Anders et al. | 2011
- 743
-
Use of micro-CT-based finite element analysis to accurately quantify peri-implant bone strains: a validation in rat tibiaeTorcasio, Antonia / Zhang, Xiaolei / Van Oosterwyck, Hans / Duyck, Joke / Lenthe, G. Harry et al. | 2011