Wear simulation of a polyethylene-on-metal cervical total disc replacement under different concentrations of bovine serum lubricant (Englisch)
- Neue Suche nach: Hyde, PJ
- Neue Suche nach: Fisher, J
- Neue Suche nach: Hall, RM
- Neue Suche nach: Hyde, PJ
- Neue Suche nach: Fisher, J
- Neue Suche nach: Hall, RM
In:
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
;
230
, 5
;
481-488
;
2016
- Aufsatz (Zeitschrift) / Elektronische Ressource
-
Titel:Wear simulation of a polyethylene-on-metal cervical total disc replacement under different concentrations of bovine serum lubricant
-
Beteiligte:
-
Erschienen in:
-
Verlag:
- Neue Suche nach: SAGE Publications
-
Erscheinungsdatum:01.05.2016
-
Format / Umfang:8 pages
-
ISSN:
-
DOI:
-
Medientyp:Aufsatz (Zeitschrift)
-
Format:Elektronische Ressource
-
Sprache:Englisch
-
Schlagwörter:
-
Datenquelle:
Inhaltsverzeichnis – Band 230, Ausgabe 5
Zeige alle Jahrgänge und Ausgaben
Die Inhaltsverzeichnisse werden automatisch erzeugt und basieren auf den im Index des TIB-Portals verfügbaren Einzelnachweisen der enthaltenen Beiträge. Die Anzeige der Inhaltsverzeichnisse kann daher unvollständig oder lückenhaft sein.
- 345
-
Physical Joint SimulatorsDowson, Duncan / Unsworth, Anthony et al. | 2016
- 347
-
Can physical joint simulators be used to anticipate clinical wear problems of new joint replacement implants prior to market release?Medley, John B et al. | 2016
- 359
-
Some aspects of frictional measurements in hip joint simulatorsUnsworth, Anthony et al. | 2016
- 366
-
Friction measurement in a hip wear simulatorSaikko, Vesa et al. | 2016
- 373
-
Simultaneous measurement of friction and wear in hip simulatorsHaider, Hani / Weisenburger, Joel N / Garvin, Kevin L et al. | 2016
- 389
-
Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearingsAli, Murat / Al-Hajjar, Mazen / Partridge, Susan / Williams, Sophie / Fisher, John / Jennings, Louise M et al. | 2016
- 398
-
Measurement outcomes from hip simulatorsde Villiers, Danielle / Shelton, Julia C et al. | 2016
- 406
-
Incorporating corrosion measurement in hip wear simulators: An added complication or a necessity?Neville, Anne / Hesketh, James / Beadling, Andrew R / Bryant, Michael G / Dowson, Duncan et al. | 2016
- 421
-
Evaluation of total knee mechanics using a crouching simulator with a synthetic knee substituteLowry, Michael / Rosenbaum, Heather / Walker, Peter S et al. | 2016
- 429
-
The influence of simulator input conditions on the wear of total knee replacements: An experimental and computational studyBrockett, Claire L / Abdelgaied, Abdellatif / Haythornthwaite, Tony / Hardaker, Catherine / Fisher, John / Jennings, Louise M et al. | 2016
- 440
-
Foot–ankle simulators: A tool to advance biomechanical understanding of a complex anatomical structureNatsakis, Tassos / Burg, Josefien / Dereymaeker, Greta / Jonkers, Ilse / Vander Sloten, Jos et al. | 2016
- 450
-
The design and development of a finger joint simulatorJoyce, Thomas J et al. | 2016
- 458
-
Wear simulation strategies for reverse shoulder arthroplasty implantsLangohr, G Daniel G / Athwal, George S / Johnson, James A / Medley, John B et al. | 2016
- 470
-
Engineering of a multi-station shoulder simulatorSmith, Simon L / Li, Lisa / Joyce, Thomas J et al. | 2016
- 481
-
Wear simulation of a polyethylene-on-metal cervical total disc replacement under different concentrations of bovine serum lubricantHyde, PJ / Fisher, J / Hall, RM et al. | 2016
- 489
-
Thanks to reviewers| 2016