Endoscope system with plasma flushing and separator for off-pump cardiac surgery (Englisch)
- Neue Suche nach: Horiuchi, T.
- Neue Suche nach: Masamune, K.
- Neue Suche nach: Yamashita, H.
- Neue Suche nach: Tsukihara, H.
- Neue Suche nach: Takamoto, S.
- Neue Suche nach: Liao, H.
- Neue Suche nach: Dohi, T.
- Neue Suche nach: Horiuchi, T.
- Neue Suche nach: Masamune, K.
- Neue Suche nach: Yamashita, H.
- Neue Suche nach: Tsukihara, H.
- Neue Suche nach: Takamoto, S.
- Neue Suche nach: Liao, H.
- Neue Suche nach: Dohi, T.
In:
World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany
;
324-327
;
2009
- Aufsatz/Kapitel (Buch) / Elektronische Ressource
-
Titel:Endoscope system with plasma flushing and separator for off-pump cardiac surgery
-
Beteiligte:Horiuchi, T. ( Autor:in ) / Masamune, K. ( Autor:in ) / Yamashita, H. ( Autor:in ) / Tsukihara, H. ( Autor:in ) / Takamoto, S. ( Autor:in ) / Liao, H. ( Autor:in ) / Dohi, T. ( Autor:in )
-
Erschienen in:IFMBE Proceedings ; 25/6 ; 324-327
-
Verlag:
- Neue Suche nach: Springer Berlin Heidelberg
-
Erscheinungsort:Berlin, Heidelberg
-
Erscheinungsdatum:01.01.2009
-
Format / Umfang:4 pages
-
ISBN:
-
ISSN:
-
DOI:
-
Medientyp:Aufsatz/Kapitel (Buch)
-
Format:Elektronische Ressource
-
Sprache:Englisch
-
Schlagwörter:
-
Datenquelle:
Inhaltsverzeichnis E-Book
Die Inhaltsverzeichnisse werden automatisch erzeugt und basieren auf den im Index des TIB-Portals verfügbaren Einzelnachweisen der enthaltenen Beiträge. Die Anzeige der Inhaltsverzeichnisse kann daher unvollständig oder lückenhaft sein.
- 1
-
Implementation of a programmable linear motor in a new minimal- invasive aortic valve resection toolStühle, S. / Wendt, D. / Wendt, H. / Thielmann, M. / Kipfmüller, B. / Hauck, F. / Vogel, B. / Jakob, H. et al. | 2009
- 4
-
Tactile Control: Fixation of Length for Artificial ChordaeBraun, E. U. / Voss, B. / Mayer, H. / Knoll, A. / Bauernschmitt, R. / Lange, R. et al. | 2009
- 6
-
Features in Telemanipulation for Heart Surgery: Haptic TasksBraun, E. U. / Gaertner, C. / Mayer, H. / Staub, C. / Knoll, A. / Lange, R. / Bauernschmitt, R. et al. | 2009
- 8
-
Liver Resection Using High Frequency Electromagnetic ThermotherapyHuang, Sheng-Chieh / Tsai, Hung-Wen / Huang, Chih-Hao / Zuchini, Roberto / Lo, Chong-Jeh / Lin, Xi-Zhang / Lee, Gwo-Bin et al. | 2009
- 12
-
CQM - the Unknown Risk in ElectrosurgeryNessler, N. H. / Salchner, M. et al. | 2009
- 16
-
Bilateral-array focused ultrasound transducer with dual-frequency mode for blood-brain barrier opening in presence of microbubblesWu, Sheng-Kai / Lee, Pei-Chi / Lee, Yung-Shin / Wu, Xin-Yu / Fu, Wen-Mei / Lin, Win-Li et al. | 2009
- 20
-
CALIBRATION OF THE MAGNETIC TRACKER FOR ACQUISITION OF 3D IMAGES TO GUIDE NEUROSURGERIESBosnjak, A. / Carmona, R. / Ríos, L. / Montilla, G. / Jara, I. et al. | 2009
- 24
-
Temperature mapping for MR-guided radiofrequency ablation - how accurate can cell necrosis be monitored?Rempp, H. / Clasen, S. / Boss, A. / Claussen, C. D. / Pereira, P. L. / Schick, F. et al. | 2009
- 28
-
Needle Insertion Test by Porcine Ligamentum FlavumNaemura, K. / Saito, H. et al. | 2009
- 32
-
Feasibility and Medical Impact Assessment of Handheld-Mobile-Robot usage in Image Guided CraniotomyKane, G. / Eggers, G. / Ionescu, H. / Vieira, V. M. M. / Boesecke, R. / Raczkowsky, J. / Wörn, H. / Marmulla, R. et al. | 2009
- 36
-
LAPAROSOUNDTM - AN ULTRASONIC METHOD AND DEVICE FOR TISSUE MORCELLATION IN LAPAROSCOPIC SURGERY, UTILIZING HIGH AMPLITUDE WAVEGUIDESMalinowski, Igor / Lobodzinski, Suave S. / Paśniczek, Roman et al. | 2009
- 39
-
Using microbubble contrast agent of different dosage to enhancing liver ablation induced by high-intensity focused ultrasoundLi, Faqi / Fu, Liyuan et al. | 2009
- 43
-
Development of Radiolucent Headholder Pins for Intraoperative CT-ImagingRadina, C. / Krampe, E. / Edlauer, M. / Winkler, P. A. / Wintermantel, E. et al. | 2009
- 47
-
Robotic Magnetic Manoeuvring of Endoscopic Video Capsules: Phantom TestsCarpi, Federico et al. | 2009
- 51
-
Implementation of real-time 2D/3D image registration in radiation oncologyGendrin, C. / Weber, C. / Figl, M. / Georg, D. / Bergmann, H. / Birkfellner, W. et al. | 2009
- 55
-
Optimizing the Setup Configuration for Manual and Robotic Assisted Minimally Invasive SurgeryWörn, H. / Weede, O. et al. | 2009
- 59
-
A Hand Guided Robotic Planning System for Laser Osteotomy in SurgeryMönnich, H. / Stein, D. / Raczkowsky, J. / Wörn, H. et al. | 2009
- 63
-
Navigated Ultrasound in Total Hip ArthroplastySüdhoff, I. / König, C. / Mollard, B. / Sharenkov, A. / Hasart, O. / Heller, M. O. et al. | 2009
- 67
-
An Active Intravascular MR-Device in Micro System TechnologyFandrey, S. / Weiss, S. / Müller, J. et al. | 2009
- 71
-
Spectroscopic in vitro Studies on Joint CartilageHoffmann, M. / Meuche, F. / Klein, C. / Plettenberg, H. K. W. et al. | 2009
- 75
-
Touch- and marker-free interaction with medical softwareKipshagen, T. / Graw, M. / Tronnier, V. / Bonsanto, M. / Hofmann, U. G. et al. | 2009
- 79
-
Development of minimally invasive laser device using composite-type optical fiberscope of 1.1 mm in diameterSeki, T. / Oka, K. / Naganawa, A. / Chiba, T. et al. | 2009
- 83
-
Stereotactic Radiofrequency Ablation: Providing New Dimensions in Interventional OncologyWidmann, G. / Haidu, M. / Pallwein, L. / Kovacs, P. / Jaschke, W. / Bale, R. J. et al. | 2009
- 87
-
Image Focusing in Endoscopic SystemsLehr, H. / Daweke, R. Dreyer genannt / Schrader, S. et al. | 2009
- 91
-
Rotation resistance of new intramedullary nail made form shape memory alloy depends upon the bone diameterWiebking, U. / Stapel, N. / Hurschler, C. / Gösling, T. et al. | 2009
- 95
-
Haptic control System for a Robotic Medical System With application to surface acquisition for Joint ArthroplastyShapiro, Y. / Wolf, A. et al. | 2009
- 99
-
A Handheld Robot for Orthopedic Surgery - ITDSchwarz, M. L. / Wagner, A. / El-Shenawy, A. / Gundling, R. / Köpfle, A. / Handel, H. / Badreddin, E. / Männer, R. / Scharf, H. -P. / Götz, M. et al. | 2009
- 103
-
Hyperthermia Control Using a Computer Microwave System in Cancer TherapyRoman, N. M. / Dan, V. / Ciupa, R. V. / Pompas, V. et al. | 2009
- 106
-
Minimal invasive surgery for maxillary transversal distraction osteogenesis with piezo-surgery device based on a 3D finite element analysisBonitz, L. / Weihe, S. / Franz, E. -P. / Baumann, A. / Hassfeld, S. et al. | 2009
- 110
-
Surgical Microscope with Automated Focus AdaptationRoehl, E. / Buzug, T. M. et al. | 2009
- 114
-
Robotic Systems for MR-Guided InterventionsBock, M. / Krafft, A. / Maier, F. / Umathum, R. / Homagk, A. -K. / Alt, S. / Zhang, K. / Pitsaer, C. / Jenne, J. / Semmler, W. et al. | 2009
- 118
-
Semi-quantitative Fluorescence Endoscopy with use of ICGSchachenmayr, Hilmar / Zhorzel, Sven / Stepp, Herbert / Harréus, Ulrich / Betz, Christian Stephan et al. | 2009
- 120
-
Physical Organ Phantoms for Training in Minimal Invasive Surgery (MIS)Śliwiński, G. / Schneider, A. / Schulz, M. / Wolf, M. / Fiolka, A. / Meyer, M. / Feußner, H. / Śliwiński, Z. / Poll, R. / Thiele, C. et al. | 2009
- 124
-
A New Miniature Manipulator for Laparoscopic Camera ControlFinlay, P. A. et al. | 2009
- 128
-
Catheter and guidewire simulator for intravascular surgery (Comparison between simulation results and medical images)Takashima, K. / Ohta, M. / Yoshinaka, K. / Mukai, T. / Oota, S. et al. | 2009
- 132
-
Comparison of two cw Infrared Laser Systems emitting wavelengths at 1.92 μm and 2.01 μm for tissue dissection in liver surgeryTheisen-Kunde, D. / Danicke, Veit / Brinkmann, Ralf et al. | 2009
- 136
-
Biomechanical Aspects of Potential Stent Malapposition at Coronary Stent ImplantationSchmidt, W. / Behrens, P. / Schmitz, K. -P. et al. | 2009
- 140
-
MR Guided Focused Ultrasound for High Risk and Recurrent Breast CancerMa, C. -M. / Chen, L. / Freedman, G. / Bleicher, R. et al. | 2009
- 144
-
Design of Master Console of Surgical Robot for NOTESPark, S. H. / Lim, K. B. / Yoon, Y. S. et al. | 2009
- 148
-
Danger of Thermal Burns by Forceps at Video-assisted Electrosurgery during Spray CoagulationHirose, M. / Matsuzuki, M. / Shinbo, T. / Kokubo, K. / Kobayashi, H. et al. | 2009
- 151
-
On Testing the Effectivity of a Cryoablation System in vitro and in vivoWieser, L. / Fischer, G. / Goll, M. / Neurauter, A. / Pehböck, D. / Silye, R. / Hintringer, F. et al. | 2009
- 155
-
Robotically Assisted Focal Spot Scanning MRgFUS: Initial in vivo ExperimentsKrafft, A. J. / Maier, F. / Jenne, J. W. / Semmler, W. / Stafford, R. J. / Huber, P. E. / Bock, M. et al. | 2009
- 159
-
Computer-Assisted Needle Insertion for Abdominal InterventionsMaier-Hein, L. / Tekbas, A. / Seitel, A. / Franz, A. M. / Radeleff, B. / Pianka, F. / Müller, S. A. / Satzl, S. / Tetzlaff, R. / Wolf, I. et al. | 2009
- 163
-
New Materials for Magnetic Resonance Imaging (MRI) – Fiber-Reinforced Guide Wires and Catheters for Minimal Invasive InterventionsSchuette, A. / Brecher, C. / Steyer, M. / Krüger, S. / Krombach, G. A. et al. | 2009
- 166
-
Software-assisted Monitoring of MR-guided RFA of malignant Liver tumors: Initial clinical resultsSchmidt, D. / Weihusen, A. / Clasen, S. / Rempp, H. -J. / Schraml, Ch. / Boss, A. / Schick, F. / Peitgen, H. -O. / Claussen, C. D. / Pereira, Ph. L. et al. | 2009
- 170
-
Endoscopic assisted stone fragmentationSroka, R. / Hecht, V. / Bader, M. / Stief, C. / Siedek, V. / Leunig, A. et al. | 2009
- 173
-
User-Interaction of a Semiautomatic Trepanation SystemFollmann, A. / Janß, A. / Korff, A. / Schmieder, K. / Radermacher, K. et al. | 2009
- 177
-
A Comparison of Confocal and Two-Photon MicroendoscopyMeier, R. / Kromer, K. / Stepp, H. / Sroka, R. et al. | 2009
- 179
-
System for Laser Osteotomy in Surgery with the Kuka Lightweight Robot – First Experimental ResultsMönnich, H. / Stein, D. / Raczkowsky, J. / Wörn, H. et al. | 2009
- 183
-
Performance Evaluation of a Multi-Purpose Input Device for Computer-Assisted SurgeryJanß, A. / Ibach, B. / Lauer, W. / Radermacher, K. et al. | 2009
- 186
-
Development of an assistance system for arthroscopic surgeryFreisberg, D. / Eschweiler, J. / Lauer, W. / Radermacher, K. et al. | 2009
- 189
-
Addressing Shading-Based Laparoscopic RegistrationLamata, P. / Morvan, T. / Reimers, M. / Samset, E. / Declerck, J. et al. | 2009
- 193
-
Designing a 6 Dof Assistant Robot for Arthroscopic SurgeryShirzad, H. / Falahati, F. / Majidi, A. / Bagheri, S. et al. | 2009
- 197
-
Distance Measuring Navigation for Fetoscopic Laser Photocoagulation to Treat Twin-to-Twin Transfusion Syndrome: Feasibility EvaluationsYamashita, H. / Yamashita, T. / Masamune, K. / Liao, H. / Kim, K. / Chiba, T. / Dohi, T. et al. | 2009
- 201
-
Volume Rendering for Planning and Performing Neurosurgical InterventionsEisenmann, U. / Freudling, A. / Metzner, R. / Hartmann, M. / Wirtz, C. R. / Dickhaus, H. et al. | 2009
- 205
-
Software Assistance for Intra-Operative Guidance in Liver SurgeryZidowitz, S. / Hansen, C. / Schlichting, S. / Kleemann, M. / Peitgen, H. -O. et al. | 2009
- 209
-
Ex Vivo Experiment of Bovine Liver using Cool-TipTM Radiofrequency Ablation SystemMah, Y. H. / Ng, K. H. / Abdullah, B. J. J. / Kwek, K. H. / Wong, J. H. D. et al. | 2009
- 213
-
Phenomenological Models for Intraoperative Positron Emission Surface Imaging using Handheld ProbesOezguer, C. / Bieniarz, J. / Lasser, T. / Ziegler, S. I. / Navab, N. / Wendler, T. et al. | 2009
- 217
-
Development of a New Vascular Endoscopic System for Observing Inner Wall of Aorta Using Intermittent Saline JetTanaka, S. / Tokugi, K. / Ogawa, M. / Motoi, K. / Nogawa, M. / Ohtake, H. / Watanabe, G. / Yamakoshi, K. et al. | 2009
- 220
-
Endoscopic Guided Brachytherapy in Gastric CancerHariri, S. / Aghamiri, M. R. / Najarian, S. / Jaberi, R. / Azmi, M. / Dehghan, H. R. / Hajizadeh, S. et al. | 2009
- 224
-
The MITK Image Guided Therapy Toolkit and Its Exemplary Application for Augmented Reality Guided Prostate SurgeryBaumhauer, M. / Neuhaus, J. / Meinzer, H. -P. et al. | 2009
- 228
-
HapCath: Highly Miniaturized Piezoresistive Force Sensors for Interior Palpation of Vessels during AngioplastyMeiß, T. / Kern, T. A. / Sindlinger, S. / Werthschützky, R. et al. | 2009
- 232
-
Vascular electromagnetic tracking: experiences in phantom and animal cadaveric modelsPenzkofer, T. / Bruners, P. / Isfort, P. / Elfring, R. / Fritschi, A. / Roost, F. / Hormes, M. / Günther, R. W. / Schmitz-Rode, T. / Mahnken, A. H. et al. | 2009
- 235
-
3D Observation of Expansion of Stent and Elastic Recoil using Micro-CTMori, Futoshi / Nakayama, Toshio / Matsuzawa, Teruo / Ohta, Makoto et al. | 2009
- 239
-
Prototype of an online navigation system for laparoscopic radiofrequency ablation of liver tumorsHildebrand, P. / Kleemann, M. / Schlichting, S. / Besirevic, A. / Roblick, U. / Bürk, C. / Bruch, H. -P. et al. | 2009
- 243
-
A Novel In Vitro Method for Assessing the Resistance to Distal Displacement of Endovascular Stent Grafts for Abdominal Aortic Aneurysm RepairCorbett, T. J. / Callanan, A. / O’Donnell, M. R. / McGloughlin, T. M. et al. | 2009
- 247
-
TAM – A Thermal Ablation Monitoring Tool: In vivo EvaluationMaier, Florian / Krafft, Axel J. / Jenne, Jürgen W. / Semmler, Wolfhard / Bock, Michael et al. | 2009
- 251
-
Endoscopic Video Images Analysis for Surgical Training and Image-Guided SurgerySánchez-González, P. / Oropesa, I. / Cano, A. M. / Gayá, F. / Lamata, P. / Sánchez-Margallo, F. M. / Pozo, F. / Gómez, E. J. et al. | 2009
- 255
-
A System for Intraoperative Optical Imaging in Clinical Routine and 3D VisualizationMeyer, T. / Sobottka, S. B. / Steinmeier, R. / Koch, E. / Schackert, G. / Morgenstern, U. et al. | 2009
- 259
-
Setup of a Scientific Research Platform for Robot-Assisted Minimally Invasive Heart Surgery ScenariosStaub, C. / Mayer, H. / Osa, T. / Braun, E. U. / Knoll, A. / Bauernschmitt, R. et al. | 2009
- 263
-
Integrated Software for Fusion of CT- and Rotational Angiography for Image Guided Neurosurgery on Cerebral AneurysmsMetzner, R. / Rüppell, J. / Haase, S. / Floca, R. / Eisenmann, U. / Hartmann, M. / Wirtz, C. R. / Dickhaus, H. et al. | 2009
- 267
-
The Kinematic Design of the New Endoscope Manipulator System (EMS) for Functional Endoscopic Sinus Surgery and Familiar Techniques in ENT SurgeryKrinninger, M. / Strauß, G. / Markert, M. / Kraus, T. / Dietz, A. / Lueth, T. et al. | 2009
- 271
-
A New Piezo Actuator Drive for Magnetic Resonance ImagingVogl, M. / Kraus, T. / Zeichfüßl, R. / Wallenhauer, C. / Gottlieb, B. / Kappel, A. / Peller, M. / Lüth, T. C. et al. | 2009
- 274
-
Single Port Surgery and NOTES Activities in 29 yearsBuess, Gerhard et al. | 2009
- 276
-
A new partially autonomous camera control systemPolski, M. / Fiolka, A. / Can, S. / Schneider, A. / Feussner, H. et al. | 2009
- 278
-
Prospective Evaluation of a fluid driven electromagnetic support system for solo-surgeryHärtl, F. / Maifeld, J. / Schneider, A. / Feussner, H. et al. | 2009
- 282
-
Development and validation of a new ex vivo training unit for NOTESGillen, S. / Fiolka, A. / Simka, S. / Feußner, H. et al. | 2009
- 285
-
Development of Master-Slave System with Force-Rate Control for Interventional RadiologyIde, Masaru / Zobel, Pierluigi Beomonte / Claudio, Paolo / Komeda, Takashi et al. | 2009
- 289
-
Concepts for Completely Absorbable Wound Closing Rivets and Prototype ManufacturingAguib, H. / Lueth, T. et al. | 2009
- 293
-
Live endoscopic video streams augmented for 3D-navigationKral, F. / Güler, Ö. / Bickel, M. / Puschban, J. / Freysinger, W. et al. | 2009
- 296
-
Automatic Intracardiac Mapping of the Left Atrium Using Magnetic Navigation: A New Dimension of Catheter NavigationÜcer, Ekrem / Luik, Armin / Reents, Tilko / Estner, Heidi / Pflaumer, Andreas / Hessling, Gabriele / Schmitt, Claus et al. | 2009
- 299
-
Tactile Feedback for Artery Detection in Minimally Invasive Robotic Surgery – Preliminary Results of a New ApproachKuebler, B. / Gruber, R. / Joppek, Ch. / Port, J. / Passig, G. / Nagel, J. H. / Hirzinger, G. et al. | 2009
- 303
-
Computer Assisted Transapical Aortic Valve ImplantationGessat, M. / Karar, M. E. / Walther, T. / Falk, V. / Burgert, O. et al. | 2009
- 307
-
Design Optimisation of a Biologically Inspired Multi-Part Probe for Soft Tissue SurgeryFrasson, L. / Reina, S. / Davies, B. L. / Baena, F. Rodriguez y et al. | 2009
- 311
-
A Symmetry-Based Approach for Non-invasive Determination of the Pelvic Coordinate System Using Ultrasound with the Patient in the Lateral PositionFieten, L. / Eschweiler, J. / Hananouchi, T. / Kabir, K. / Gravius, S. / Heger, S. / Wirtz, D. C. / Radermacher, K. et al. | 2009
- 314
-
A Smart Generic Micro-drilling Tool Applied in CochleostomyBrett, P. N. / Taylor, R. P. / Du, Xinli / Proops, D. / Griffiths, M. V. / Coulson, C. et al. | 2009
- 317
-
Operational Concept for a Handheld Laparoscopic Telemanipulation System: Design and Animal ExperimentKassner, S. / Röse, A. / Werthschützky, R. / Schlaak, H. et al. | 2009
- 321
-
Quaternion: An Alternate Approach to Medical NavigationKozak, J. / Friedrich, D. et al. | 2009
- 324
-
Endoscope system with plasma flushing and separator for off-pump cardiac surgeryHoriuchi, T. / Masamune, K. / Yamashita, H. / Tsukihara, H. / Takamoto, S. / Liao, H. / Dohi, T. et al. | 2009
- 328
-
Accuracy of Optical Localizers for Computer Aided SurgeryElfring, R. / Fuente, M. / Radermacher, K. et al. | 2009
- 331
-
A new Intra-Articular Load Measuring Device for Ligament Balancing and Prothesis Alignment in Total Knee ArthroplastySchmidt, F. / Elfring, R. / Nolten, U. / Mokwa, W. / Radermacher, K. et al. | 2009
- 333
-
Physiological Parameters Based Control Scheme for Automatic Intravascular Balloon InflationSette, M. M. / Furtado, H. / Stüdeli, T. / Morita, T. / Elle, O. J. / Brussel, H. / Vander Sloten, J. et al. | 2009
- 337
-
Tumor Treatment System with Alternate Cooling and Heating - Preliminary Results in an Animal ModelSun, J. Q. / Xu, C. C. / Wei, G. H. / Sun, X. G. / Liu, P. / Zhang, A. L. / Xu, L. X. et al. | 2009
- 341
-
Enhancement of Drug Delivery in Prostate Tumor in vivo Using MR Guided Focused Ultrasound (MRgHIFU)Chen, L. / Mu, Z. / Hachem, P. / Ma, C. -M. / Pollack, A. et al. | 2009
- 345
-
Multisensor Soft Tissue Navigation for the Controlled Guidance in Intra-Cardiac MicrosurgeryBrell, M. / Isken, M. / Hein, A. / Dahmen, C. / Tunnell, R. / Wortmann, T. / Sill, A. / Fatikow, S. / Bombien, R. / Lutter, G. et al. | 2009
- 349
-
Evaluation of the Application Accuracy of 3D-Navigation through Measurements and PredictionBickel, M. / Güler, Ö. / Kral, F. / Schwarm, F. / Freysinger, W. et al. | 2009
- 355
-
Implementation of quality control devices for intraoperative gamma probe Preliminary results of performance testsVarela, C. / Salvador, F. J. / Abreu, N. J. / Ramos, D. / Palau, A. / Díaz, M. / Ventura, K. et al. | 2009
- 359
-
New Video Component for the Image Guided Surgery Toolkit IGSTKGüler, Ö. / Yaniv, Z. / Cleary, K. / Freysinger, W. et al. | 2009
- 361
-
Active Robotic Capsules for Wireless EndoscopySchurr, M. O. / Menciassi, A. / Dario, P. et al. | 2009
- 362
-
VIRTUAL REALITY AND AUGMENTED REALITY APPLIED TO ENDOSCOPIC AND NOTES PROCEDURESSoler, Luc / Nicolau, Stéphane / Hostettler, Alexandre / Fasquel, Jean-Baptiste / Agnus, Vincent / Charnoz, Arnaud / Moreau, Johan / Dallemagne, Bernard / Mutter, Didier / Marescaux, Jacques et al. | 2009
- 366
-
Advanced Neuronavigation and Image-Guided Interventions in NeurosurgerySeifert, Volker et al. | 2009
- 367
-
Special Keynote Speech:“20 years of OCT in ophthalmology - an example of successful innovation management between research, clinics and industry”Kaschke, Michael et al. | 2009