How Regular Motion Pattern and Patient Individual Respiration Curves Affect Contour and Volume of Geometric Structures in a 4D CT (Englisch)
- Neue Suche nach: Block, A.
- Neue Suche nach: Noertersheuser, T.
- Neue Suche nach: Mewes, A.
- Neue Suche nach: Bauer, R.
- Neue Suche nach: Block, A.
- Neue Suche nach: Noertersheuser, T.
- Neue Suche nach: Mewes, A.
- Neue Suche nach: Bauer, R.
In:
World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany
;
776-779
;
2009
- Aufsatz/Kapitel (Buch) / Elektronische Ressource
-
Titel:How Regular Motion Pattern and Patient Individual Respiration Curves Affect Contour and Volume of Geometric Structures in a 4D CT
-
Beteiligte:Block, A. ( Autor:in ) / Noertersheuser, T. ( Autor:in ) / Mewes, A. ( Autor:in ) / Bauer, R. ( Autor:in )
-
Erschienen in:IFMBE Proceedings ; 25/1 ; 776-779
-
Verlag:
- Neue Suche nach: Springer Berlin Heidelberg
-
Erscheinungsort:Berlin, Heidelberg
-
Erscheinungsdatum:01.01.2009
-
Format / Umfang:4 pages
-
ISBN:
-
ISSN:
-
DOI:
-
Medientyp:Aufsatz/Kapitel (Buch)
-
Format:Elektronische Ressource
-
Sprache:Englisch
-
Schlagwörter:
-
Datenquelle:
Inhaltsverzeichnis E-Book
Die Inhaltsverzeichnisse werden automatisch erzeugt und basieren auf den im Index des TIB-Portals verfügbaren Einzelnachweisen der enthaltenen Beiträge. Die Anzeige der Inhaltsverzeichnisse kann daher unvollständig oder lückenhaft sein.
- 1
-
Development of New Radioactive Seeds Tm-170 for BrachytherapyAyoub, Amal / Shani, Gad et al. | 2009
- 5
-
Implications of Histogram Analysis in Radiation Therapy (HART) SoftwarePyakuryal, A. et al. | 2009
- 9
-
Evaluation of dosimetric characteristics of a grid block fabricated for Mega-voltage grid therapy purposesSani, Karim Ghazi-khanlou et al. | 2009
- 13
-
Monte Carlo Investigation of Stereotactic Radiosurgery of Spinal MetastasesDeng, J. / Chen, Z. / Knisely, J. / Decker, R. / Chiang, V. / Nath, R. et al. | 2009
- 17
-
Impact of Kilo-Voltage Cone Beam Computed Tomography on Image-Guided Radiotherapy of Prostate CancerDeng, J. / Chen, Z. / Nath, R. et al. | 2009
- 21
-
Cell Deformation by Dielectrophoretic FieldsGuido, I. / Jaeger, M. S. / Duschl, C. et al. | 2009
- 25
-
Particle-beam radiation therapy for the tumor of pharyngeal regionMurakami, M. / Niwa, Y. / Demizu, Y. / Miyawaki, D. / Terashima, K. / Arimura, T. / Hishikawa, Y. et al. | 2009
- 29
-
A New Synchrotron Radiotherapy Technique with Future Clinical Potential: Minibeams Radiation TherapyPrezado, Y. / Renier, M. / Bravin, A. et al. | 2009
- 33
-
Analysis of combined HDR Brachytherapy and external beam radiotherapy in the treatment of carcinoma of cervixKehwar, T. S. / Passi, Kamlesh / Vashistha, Rajesh / Singh, Bikramjit / Jain, Veena / Gupta, Sureshchandra J. et al. | 2009
- 37
-
Motion detection system with three USB cameras and an active search algorithm for stereotactic radiosurgeryOgawa, K. / Mamiya, G. / Iyatomi, H. / Oku, Y. / Kunieda, E. et al. | 2009
- 41
-
An Investigation of the concomitant doses from Cone Beam CT and CT simulation in RadiotherapyPotts, R. / Oatey, M. et al. | 2009
- 45
-
Treatment Planning for Volumetric Modulated Arc Therapy (VMAT)Bedford, J. L. et al. | 2009
- 49
-
The 21st Birthday Party for intensity-modulated radiation therapy (IMRT); 21 years from 1988-2009; From concept to practical realityWebb, S. et al. | 2009
- 53
-
A Dedicated Irradiation Facility for Radiotherapy DosimetryDerikum, K. et al. | 2009
- 56
-
A beam model applicable to small fields: development and validationCaprile, P. / Hartmann, G. H. et al. | 2009
- 60
-
MR based treatment workflow for external radiotherapy of prostate cancerNyholm, T. / Karlsson, M. G. / Karlsson, M. et al. | 2009
- 64
-
Computational Simulation of Tumour Hypoxia as applied to Radiation Therapy ApplicationsDalah, E. / Lloyd, D. / Bradley, D. / Nisbet, A. et al. | 2009
- 67
-
Investigation of the Recovery Behaviour as Depending on Parotid Gland Irradiation DoseGerlach, Reinhard / Stock, Markus / Koizar, Susanne / Stromberger, Carmen / Georg, Dietmar / Janich, Martin et al. | 2009
- 70
-
Quality Assurance Program for Radiosurgery at Clinicas Hospital: Results of ImplementationRodrigues, L. N. / Menegussi, G. / Silva, M. A. / Rubo, R. / Furnari, L. / Sales, C. P. / Santos, G. R. et al. | 2009
- 72
-
Application of MRI normoxic polymer gel dosimetry for the evaluation of radiation dose distribution in external beam radiotherapyToossi, M. T. Bahreyni / Toossi, M. H. Bahreyni / Safaeian, Gh. / Hashemian, A. / Bayani, Sh. et al. | 2009
- 76
-
On the Risks of a Constant RBE for Proton Treatment PlanningFrese, M. C. / Taheri-Kadkhoda, Z. / Wilkens, J. J. / Oelfke, U. et al. | 2009
- 80
-
Comparison of Dose Distribution in Brain Tumor Conformal Radiotherapy Using CT and CBCTLu, Jie / Yin, Yong / Li, Jianbin et al. | 2009
- 81
-
Effect of the Same Plan on Doses to Patients during Radiotherapy with Nasopharyngeal CarinomaLu, Jie / Yin, Yong / Bai, Tong et al. | 2009
- 82
-
Optimization of Dose Distribution with Multi-leaf Collimator Using Field-in-Field Technique for Radiotherapy of Hodgkin’s LymphomaCella, L. / Liuzzi, R. / Magliulo, M. / Conson, M. / Camera, L. / Salvatore, M. / Pacelli, R. et al. | 2009
- 85
-
On the performance of monitor chambers to measure the output of medical linear accelerators for high-precision dosimetric investigationsKapsch, R. -P. / Krauss, A. et al. | 2009
- 89
-
Calorimetric Determination of Absorbed Dose to Water for an 192Ir HDR Brachytherapy Source in Near-Field GeometryBambynek, M. / Krauss, A. / Selbach, H. -J. et al. | 2009
- 93
-
The first national IMRT dosimetry inter comparison in Switzerland using a thorax phantom with inhomogeneitiesSchiefer, H. / Nicolini, G. / Fogliata, A. / Seelentag, W. W. / Fix, M. K. et al. | 2009
- 97
-
Calibration of 125I brachytherapy sources in terms of reference air kerma rateSelbach, H. -J. et al. | 2009
- 101
-
A Mathematical Aid Decision Tool for RT PlanningSotolongo-Grau, O. / Rodríguez-Pérez, D. / Santos-Miranda, J. A. / Desco, M. M. / Sotolongo-Costa, O. / Antoranz, J. C. et al. | 2009
- 105
-
Accuracy of GafChromic EBT Film as Dose Meter in Radiotherapy QABattum, L. J. / Hoffmans, D. / Kwa, S. / Heukelom, S. et al. | 2009
- 109
-
Low-Dose Cone-Beam CT Imaging for RadiotherapyWang, Jing / Li, Tianfang / Xing, Lei et al. | 2009
- 113
-
The realization and application on image pasting for Cone-beam Computed TomographyYongm, Y I N / Jian, Z H U / Jie, L U et al. | 2009
- 114
-
In vivo dosimetry using MOSFET and TLD for TomotherapyKinhikar, Rajesh A. / Tambe, Chandrshekhar M. / Dhote, Dipak S. / Deshpande, Deepak D. et al. | 2009
- 117
-
Dose audit using a glass dosimeter for Radiation Therapy Facilities in East-Asian CountriesMizuno, H. / Nakamura, Y. K. / Sakata, S. / Tabushi, K. / Kusano, Y. / Nagano, A. / Fukumura, A. / Kanai, T. / Tsujii, H. et al. | 2009
- 119
-
Editing range compensator for sparing normal tissue in treatment planning of carbon-ion radiotherapyMizota, M. / Kanematsu, N. et al. | 2009
- 122
-
A new device for the measurement of the absorbed dose to water for low energy x-ray sources used in brachytherapySchneider, T. / Meier, M. / Selbach, H. J. et al. | 2009
- 126
-
Comparison of PET Concepts for Dose Delivery Monitoring of Particle TherapyKunath, D. / Braess, H. / Fiedler, F. / Laube, K. / Parodi, K. / Priegnitz, M. / Shakirin, G. / Enghardt, W. et al. | 2009
- 130
-
Image-guided stereotactic body radiation therapy using a low-Z target imaging beam line and a high dose rate unflattened beamGayou, O. et al. | 2009
- 133
-
Conformity of brain lesions treated with radiosurgery and fractionated stereotactic radiotherapyLopes, M. C. / Capela, M. / Ferreira, B. C. / Ventura, T. et al. | 2009
- 137
-
Comparing pencil-beam generated and Monte Carlo generated dose-to-water and dose-to-tissue distributions for proton therapy patientsPaganetti, H. et al. | 2009
- 141
-
In Vivo Evaluation of Photofrin II Radiosentisitivity for the Treatment of Adenocarcinoma Tumors in Balb-C Mice using BrachytherapyMoradi, A. / Hashemi, B. / Hassan, Z. et al. | 2009
- 144
-
Extend Distance Treatment for Stereotactic Body Radiation Therapy of Lung CancerHuang, Long / Papiez, Lech / Abolfath, Ramin M. / Papiez, Ewa / Timmerman, Robert / Solberg, Timothy D. et al. | 2009
- 148
-
Monte Carlo dosimetry with PENELOPE code of the VariSource VS2000 192Ir high dose rate brachytherapy sourceCasado, F. J. / Mateo, B. / Cenizo, E. / García-Pareja, S. / Galán, P. / Bodineau, C. et al. | 2009
- 152
-
Energy Dependence Investigations of GafChromic EBT Films for Pretreatment Dosimetric Verification of IMRT PlansChełmiński, K. / Bulski, W. / Georg, D. / Bodzak, D. / Maniakowski, Z. / Oborska, D. et al. | 2009
- 155
-
Design and fabrication of the control part of a prototype multileaf collimator systemToossi, M. T. Bahreyni / Hashemian, A. / Nasseri, Sh. et al. | 2009
- 158
-
Quantitative Evaluation of Gating Radiotherapy System and Dynamic Tumor Tracking Radiotherapy System Developed at KIRAMSPark, Seungwoo / Jung, Haijo / Kim, Kum Bae / Ji, Young Hoon et al. | 2009
- 162
-
Dosimetrical Aspect of CT Simulation Role in Radiation Therapy PlanningMahdavi, Seyed Rabi / Nikoofar, Alireza / Mirzaei, Hamidreza / Mofid, Bahram et al. | 2009
- 167
-
Implantable in vivo Dosimetric Probe Based on GaN RadioluminescenceIsmail, Anas / Pittet, Patrick / Lu, Guo-Neng / Galvan, Jean-Marc / Giraud, Jean-Yves / Balosso, Jacques et al. | 2009
- 172
-
Pre-clinical experiments in the deep-seated tumor heavy-ion therapy terminal at HIRFL-CSRLi, Q. / Dai, Z-Y. / Liu, X-G. / Wu, Q-F. / Jin, X-D. / Li, P. / Tao, J-J. et al. | 2009
- 175
-
Second source model of collimator scatter and spectra of proton beamsUlmer, W. et al. | 2009
- 179
-
Determination of nuclear cross sections of proton beams by the collective model and extended nuclear-shell theoryUlmer, W. / Matsinos, E. et al. | 2009
- 183
-
4D Monte Carlo Dose Calculations for Particle Therapy Combined with the Spring Network Model of Lung MotionIshikawa, K. L. / Takagi, S. / Matthys, K. / Wada, S. et al. | 2009
- 187
-
Prognostic Analysis of Three-Dimensional Conformal Radiotherapy of Regional Lymph Node Metastasis of the Surgical Esophageal Carcinoma Patients After ResectionGao, Min / Zhu, Shuchai / Wang, Yuxiang et al. | 2009
- 188
-
Quality control of brachytherapy source using MCNP5 calculation and radiochromic films measurementRódenas, J. / Gerardy, I. / Dycke, M. / Gallardo, S. et al. | 2009
- 192
-
A Monte Carlo Study of the Particle Angular Distributions from the Electron Applicators of a Medical Linear AcceleratorJabbari, N. / Hashemi, B. et al. | 2009
- 196
-
Four-Dimensional Computerized Tomography (4D-CT) Reconstruction Without an External Breath SurrogateShu-xu, Z H A N G / Lin-hong, Z H O U / Hui, Yu / Guang-jie, C H E N / Sheng-qu, L I N / Hai-nan, Z H A N G et al. | 2009
- 200
-
Usefulness of GafChromic EBT film for dosimetry beyond 8.0 GyAoyama, Hideki / Tokura, Shinsuke / Azuma, Yoshiharu / Goto, Sachiko / Inamura, Keiji et al. | 2009
- 204
-
Influence of the CT slice thickness on the dose calculation for stereotactic treatment planingJacob, V. / Kneschaurek, P. et al. | 2009
- 207
-
“F-MRI: a method to assess therapy-induced cognitive impairment?”Walter, B. et al. | 2009
- 210
-
Revaluation for problem of clinical particle therapy in cell biological effects of proton, carbon-ion and X-ray at Hyogo Ion Beam Medical CenterNagayama, S. / Murakami, M. / Maeda, T. / Baba, M. / Demizu, Y. / Hishikawa, Y. / Abe, M. et al. | 2009
- 213
-
Fast and Accurate Proton Computed Tomography Image Reconstruction for Applications in Proton TherapyPenfold, S. N. / Schulte, R. W. / Bashkirov, V. / Rosenfeld, A. B. et al. | 2009
- 217
-
Patient setup using a 3D laser surface scanning systemFrenzel, Th. et al. | 2009
- 221
-
Therapy Optimization Based on Non-linear Uptake of PET Tracers versus “Linear Dose Painting”Toma-Dasu, I. / Uhrdin, J. / Daşu, A. / Brahme, A. et al. | 2009
- 225
-
Ant colony algorithm implementation in commissioning radiosurgery photon beams for Monte Carlo treatment planningGarcía-Pareja, S. / Manzano, F. / Galán, P. / Lallena, A. M. / Brualla, L. et al. | 2009
- 229
-
Respiratory Training and Guiding System using Head Mount Display Device to improve the regularity of breathingShin, Eunhyuk / Park, Hee-Chul / Han, Youngyih / Shin, Jung Suk / Ju, Sang-Gyu / Lee, Jaiki / Ahn, Yong-Chan et al. | 2009
- 232
-
The use of aSi EPID for in vivo dosimetry in photon beams: clinical experienceBoissard, P. / François, P. / Mazal, A. et al. | 2009
- 236
-
Response of Lithium Formate EPR Dosimeters at Photon Energies Relevant to BrachytherapyAdolfsson, Emelie / Carlsson, Gudrun Alm / Grindborg, Jan-Erik / Gustafsson, Håkan / Lund, Eva / Tedgren, Åsa Carlsson et al. | 2009
- 240
-
Development of IMRT Treatment Planning SystemPark, Jeong-Hoon / Cho, Woong / Cheong, Kwang-Ho / Jung, Won-Gyun / Suh, Tae-Suk et al. | 2009
- 244
-
An Investigation on the Internal Wedge Factor Estimation for an Elekta Linac using Monte Carlo SimulationHejazi, P. / Hashemi, B. / Shahriari, M. / Eivazi, M. / Kazemnejad, A. et al. | 2009
- 248
-
Three Dimensional Gamma-Index Analysis and Considerations of the Reference Level Definition for Dosimetric IMRT Plan Verification with 2D Ionisation Chamber ArraysPoppe, B. / Ruehmann, A. / Willborn, K. / Allgaier, B. / Harder, D. et al. | 2009
- 250
-
Parameterisation of Small Photon Fields in Off-Axis Regions for the SIEMENS 160 MLCPoppe, B. / Riediger, J. / Suft, G. / Ruehmann, A. / Willborn, K. / Harder, D. et al. | 2009
- 252
-
Suitability of the MVCT of TomoTherapy and Siemens Oncor for Treatment PlanningSchmitt, D. / Albers, D. / Cremers, F. et al. | 2009
- 256
-
Measurement of Absorbed Dose to Water of a Gamma Knife Type CChung, H. T. / Park, Y. / Hyun, S. / Choi, Y. / Kim, K. H. / Chun, K. J. et al. | 2009
- 259
-
On line neutron dose evaluation in patients under radiotherapySanchez-Doblado, F. / Domingo, C. / Gómez, F. / Muñiz, J. L. / Barquero, R. / García-Fusté, M. J. / Hartmann, G. / Romero, M. T. / Terrón, J. A. / Pena, J. et al. | 2009
- 262
-
Lorentz function convolution kernel of narrow photon beam profiles in homogeneous and inhomogeneous mediaDjouguela / Harder, D. / Rühmann, A. / Willborn, K. / Poppe, B. et al. | 2009
- 266
-
FIRST ASSESSMENT OF A NOVEL IGRT DEVICE FOR STEREOTACTIC BODY RADIATION THERAPYSpeiser, M. / Medin, P. / Mao, W. / Papiez, L. / Gum, F. / Solberg, T. et al. | 2009
- 270
-
Heavy Ion Radiotherapy for Shallow-Seated Tumors at IMPLiu, X. -G. / Li, Q. / Dai, Z. -Y. et al. | 2009
- 273
-
Density response characteristics of GafChromic EBT dosimetry film using ultraviolet light exposureTokura, S. / Azuma, Y. / Aoyam, H. / Goto, S. et al. | 2009
- 277
-
Fiducial-free spinal radiosurgery: Patient motion and targeting accuracy in 227 single fraction treatments with the CyberknifeFürweger, C. / Kufeld, M. / Schlaefer, A. / Drexler, C. et al. | 2009
- 281
-
Electron arc planning on the commercial radiation treatment planning systemKang, Sei-Kwon / Hwang, Taejin / Cheong, Kwang-Ho / Park, Soah / Lee, Me-Yeon / Kim, Kyoung Ju / Oh, Do Hoon / Bae, Hoonsik et al. | 2009
- 283
-
Influence of Modulation Restriction in Inverse Optimization with HIPO of Prostate Implants on Plan Quality: Analysis Using Dosimetric and Radiobiological IndicesBaltas, D / Katsilieri, Z / Kefala, V / Papaioannou, S / Karabis, A / Mavroidis, P / Zamboglou, N et al. | 2009
- 287
-
Improving the performance of direct Monte-Carlo optimization for large tumor volumesMoret, J. Alvarez / Alt, M. / Bogner, L. et al. | 2009
- 291
-
Finite Element-Based Biomechanical Modeling of the Bladder for Image Guided RadiotherapyChai, X. / Kamer, J. B. / Herk, M. / Hulshof, M. C. C. M. / Remeijer, P. / Pos, F. / Lotz, H. T. / Bel, A. et al. | 2009
- 295
-
Verification of the accuracy in patient alignment using a laser-optical 3D-surface imaging systemMoser, T. / Fleischhacker, S. / Schubert, K. / Sroka-Perez, G. / Uhl, M. / Herfarth, K. / Debus, J. / Karger, C. P. et al. | 2009
- 299
-
LDR and HDR intracavitory brachytherapy of cancer cervix uterus- rectal doses and ERD comparisonChougule, Arun / Agarwal, D. P. et al. | 2009
- 303
-
Evaluation on Lung Cancer Patients’ Four-dimensional Treatment Plans Utilizing Biologically Effective Uniform DoseSu, Fan-Chi / Shi, Chengyu / Mavroidis, Panayiotis / Goytia, Virginia / Crownover, Richard / Rassiah-Szegedi, Prema / Baltas, Dimos / Papanikolaou, Niko et al. | 2009
- 307
-
Brachytherapy seed localization via iterative forward projection matching (IFPM) algorithm using intraoperative cone-beam-CT sinogram projectionsPokhrel, D. / Murphy, M. J. / Todor, D. A. / Lazos, D. / Weiss, E. / Motai, Y. / Williamson, J. F. et al. | 2009
- 311
-
Using Correlated Sampson to Accelerate CT-Based Monte Carlo Dose Calculations for Brachytherapy Treatment PlanningSampson, A. / Le, Y. / Todor, D. / Williamson, J. et al. | 2009
- 315
-
Investigation of a stereoscopic camera system for gated radiotherapyVasquez, A. / Moser, T. / Echner, G. / Sroka-Perez, G. / Karger, C. P. et al. | 2009
- 318
-
Extracting breathing traces from any cone-beam image-setKavanagh, A. P. / Evans, P. M. / Hansen, V. N. / Webb, S. et al. | 2009
- 322
-
A linear implementation of dose-volume constraints for multi-criteria optimizationSchlaefer, A. / Ruan, D. / Dieterich, S. / Kilby, W. et al. | 2009
- 326
-
Monte Carlo Dose Calculation for Radiotherapy Treatment Planning: Dose to Water or Dose to Medium?Ma, C. -M. / Li, J. S. et al. | 2009
- 330
-
Comparison of Contra lateral Breast & Chest wall doses during Radiotherapy of Ca-Breast (with mastectomy) using Co-60 machine and 6 MV LINAC.Faaruq, Shafqat / Mehnaz / Kakakhail, Basim / Rehman, Saeed ur et al. | 2009
- 334
-
The integration of the dose-guided radiation therapy process on a clinical workstationCheung, J. / Boettger, T. / Hu, W. / Aubry, J. F. / Pouliot, J. et al. | 2009
- 338
-
First experience with patient oriented Rapid Arc treatment plan verificationWagner, D. M. / Vorwerk, H. et al. | 2009
- 341
-
EGSnrc Monte Carlo-aided dosimetric studies of the 192Ir microSelectron v2 HDR brachytherapy sourceHong, Liu / Zakaria, G. A. / Hartmann, G. H. et al. | 2009
- 345
-
Motion management in scanned particle therapy: beam gating & trackingBert, C. / Gemmel, A. / Saito, N. / Chaudhri, N. / Lüchtenborg, R. / Durante, M. / Rietzel, E. et al. | 2009
- 349
-
Quality assurance and application of a 4D in vivo dosimetry system using a deformable lung phantomCherpak, A. / Serban, M. / Seuntjens, J. / Cygler, J. E. et al. | 2009
- 352
-
Dosimetric advantages of Stereotactic IMRT of brain lesions delivered with a micro-multileaf collimatorFerreira, B. C. / Lopes, M. C. / Capela, M. et al. | 2009
- 356
-
In vivo measurements of the dose delivered by kilovoltage cone-beam CT during prostate radiation therapyMarinello, G. / Mege, J. P. / Herve, M. L. / Lagrange, J. L. et al. | 2009
- 358
-
Initial application of a geometric QA tool for integrated MV and kV imaging systems on Trilogy, Synergy, and VeroMao, Weihua / Speiser, Michael / Medin, Paul / Papiez, Lech / Solberg, Timothy / Xing, Lei et al. | 2009
- 362
-
A New Electron IMRT Technique for Breast Cancer: Comparison to Photon IMRT and Conventional Irradiation Based on Static and Dynamic Dose MeasurementsGauer, T. / Engel, K. / Kiesel, A. / Albers, D. / Cremers, F. et al. | 2009
- 366
-
TLD Correction Factor for Dose Delivery Verification on Gamma Radiation Cobalt-60 on Clinical TreatmentPrasetio, Heru / Milvita, Dian / Djarwani, S. S. et al. | 2009
- 370
-
Development of Treatment Planning System in Peking UniversityShanglian, Bao / Yibao, Zhang / Feizeng, Huang et al. | 2009
- 373
-
Direct Monte-Carlo optimization (DMCO) with biological, physical and hybrid objective functionsDirscherl, T. / Rickhey, M. / Bogner, L. et al. | 2009
- 377
-
4D calculation and biological dosimetry of the RBE-weighted dose for scanned carbon ion beam therapyGemmel, A. / Bert, C. / Saito, N. / Chaudhri, N. / Iancu, G. / Neubeck, C. v. / Durante, M. / Rietzel, E. et al. | 2009
- 381
-
Radiobiological analysis of planned and delivered IMRT dose distributionsMavroidis, P. / Ferreira, B. Costa / Papanikolaou, N. / Svensson, R. / Lind, B. K. / Brahme, A. et al. | 2009
- 385
-
Impact of Truncation Correction in Flat-Detector Computed Tomography on Carbon Ion Radiotherapy Treatment PlanningKolditz, Daniel / Meyer, Michael / Kyriakou, Yiannis / Rietzel, Eike / Kalender, Willi A. et al. | 2009
- 389
-
Reconstruction of portal images from IMRT fields for patient setup verificationHaering, P. / Schwahofer, A. / Lang, C. / Rhein, B. et al. | 2009
- 392
-
Comparison of IMRT and photon-electron-mix technique in radiotherapy treatment planning of ablatio mammaeWeidner, K. / Bogner, L. et al. | 2009
- 396
-
Relative peripheral dose at IMRT- A comparison between Siemens Oncor and ArtistéSchwahofer, A. / Moeller, M. / Wiezorek, T. et al. | 2009
- 399
-
EPID calibration method for transit in-vivo dosimetryFidanzio, A. / Cilla, S. / Greco, F. / Azario, L. / Grimaldi, L. / Sabatino, D. / Piermattei, A. et al. | 2009
- 403
-
Guided radiotherapy by an in-vivo dosimetry for lung tumorsCilla, S. / Fidanzio, A. / Greco, F. / Grimaldi, L. / D’Onofrio, G. / Sabatino, D. / Piermattei, A. et al. | 2009
- 407
-
Implementation of a complete IMRT QA program and clinical experience with the DAVID chamber for in-vivo verification of IMRT deliveriesLooe, H. K. / Rühmann, A. / Kollhoff, R. / Kunth, W. / Chofor, N. / Harder, D. / Willborn, K. / Poppe, B. et al. | 2009
- 410
-
Enhancing the error detection capability of the DAVID system with the use of adaptive warning and alarm levelsLooe, H. K. / Rühmann, A. / Harder, D. / Poppe, B. et al. | 2009
- 413
-
PDD AND DOSE PROFILE FOR NARROW BEAMS OF A COBALT - 60 THERAPY UNIT TO BE USED IN STEREOTACTIC RADIOSURGERYMenezes, A. F. / Batista, D. V. S. / Rosa, L. A. R. et al. | 2009
- 417
-
Technical accuracy of a beam tracking system for scanned particle therapy of intra-fractionally moving targetsSaito, Nami / Bert, Christoph / Chaudhri, Naved / Gemmel, Alexander / Schardt, Dieter / Kraft, Gerhard / Durante, Marco / Rietze, Eike et al. | 2009
- 421
-
A Joint Research Project to improve the accuracy in dosimetry of brachytherapy treatments in the framework of the European Metrology Research Programme.Toni, M. P. / Aubineau-Lanièce, I. / Bovi, M. / Cardoso, J. / Cutarella, D. / Gabris, F. / Grindborg, J. E. / Guerra, A. S. / Jarvinen, H. / Oliveira, C. et al. | 2009
- 425
-
Proposals for a ICRU-50/62 -Consistent Dose Prescription Suited for IMRT Radiation TechniquesOechsner, M. / Bratengeier, K. / Gainey, M. / Flentje, M. et al. | 2009
- 429
-
Fast Dose Calculations in Radiation Therapy with GPUsDesprés, Philippe / Hissoiny, Sami / Gariépy, Jean-Philippe / Ozell, Benoît et al. | 2009
- 433
-
Robust Radiobiological Optimization for Proton Therapy Treatment PlanningKroupal, F. / Frese, M. C. / Heath, E. / Oelfke, U. et al. | 2009
- 437
-
Neutron Therapy at the FRMII - Calculation of Dose inside a Voxel PhantomGarny, S. / Rühm, W. / Wagner, F. M. / Paretzke, H. G. et al. | 2009
- 441
-
Monte Carlo based independent monitor unit calculation in IMRTPisaturo, O. / Moeckli, R. / Bochud, F. O. et al. | 2009
- 445
-
Suggestion for an extended quality assurance in 4D CT and its function in gated radiotherapy using a motion phantomBlock, A. / Mewes, A. et al. | 2009
- 449
-
On-line compensation of dose changes introduced by tumor motion during scanned particle therapyLüchtenborg, R. / Saito, N. / Chaudhri, N. / Durante, M. / Rietzel, E. / Bert, C. et al. | 2009
- 453
-
Feasibility Study of the Use of Artificial Neural Networks in Predicting Acute Rectal and Urinary Bladder Toxicity Following Prostate Cancer RadiotherapyPella, A. / Cambria, R. / Jereczek-Fossa, B. A. / Zerini, D. / Fodor, C. / Serafini, F. / Baroni, G. / Riboldi, M. / Ciceri, M. / Spadea, M. F. et al. | 2009
- 457
-
Imaging QA Program for Image Guided RadioTherapy (IGRT)Schubert, K. / Wagenknecht, K. / Lissner, S. / Sroka-Perez, G. / Debus, J. et al. | 2009
- 460
-
Dose QA Using EPID and a Dose Prediction Algorithm Independent of the Planning SystemBerndt, J. / Misslbeck, M. / Kneschaurek, P. et al. | 2009
- 463
-
Investigation of the Dose Distribution Quality Achievable with Arc-Modulated Cone Beam TherapyUlrich, S. / Sterzing, F. / Nill, S. / Schubert, K. / Herfarth, K. K. / Debus, J. / Oelfke, U. et al. | 2009
- 467
-
Investigating the Reproducibility of Motion for Lung Tumours Treated with Stereotactic Body RadiotherapyRichter, A. / Wilbert, J. / Baier, K. / Guckenberger, M. / Flentje, M. et al. | 2009
- 470
-
A Feasibility Study on Multi Prompt-Gamma-Ray Telescope System for Boron Neutron Capture TherapySakurai, Y. / Tanaka, H. / Suzuki, M. / Kashino, G. / Kinashi, Y. / Masunaga, S. / Ono, K. / Maruhashi, A. et al. | 2009
- 474
-
Measurement of Inter-fraction Changes in Bladder Volume Using Ultrasound Image Guidance for Gynecological RadiotherapyKim, Hayeon / Beriwal, Sushil / Huq, M. Saiful et al. | 2009
- 476
-
A comparison of dose and energy-based mapping methods for 4D Monte Carlo dose calculation in deforming anatomyHeath, E. / Kawrakow, I. / Tessier, F. / Siebers, J. V. et al. | 2009
- 479
-
IGRT and its Quality Assurance at the DKFZLang, C. / Rhein, B. / Häring, P. / Schwahofer, A. et al. | 2009
- 481
-
Implementing Volumetric Modulated Arc Therapy (VMAT): Initial Dosimetric Results for Retrospective Patient StudyRichter, A. / Wilbert, J. / Krieger, T. / Guckenberger, M. / Baier, K. / Schwab, F. / Flentje, M. et al. | 2009
- 484
-
Influence of Patient Movement and Anatomy Alteration on the Quality of 3D US-Based Prostate HDR Brachytherapy TreatmentMilickovic, N. / Nikolova, I. / Tselis, N. / Azhari, H. A. / Zamboglou, N. / Baltas, D. et al. | 2009
- 488
-
Clinical Evaluation of an Intra-Modality 3D Ultrasound IGRT SystemKleefeld, C. / Moore, M. / Putten, W. et al. | 2009
- 492
-
Quality assurance of a robotic, image guided radiosurgery systemDrexler, C. / Fürweger, C. et al. | 2009
- 496
-
Impact of Beam Alignment on Leakage of the Siemens 160 MLCTMKlüter, S. / Sroka-Perez, G. / Schubert, K. / Debus, J. et al. | 2009
- 499
-
Observations of Prostate Intrafractional Motion during External Beam Radiation TherapyLi, J. S. / Pollack, A. / Horwitz, E. M. / Buyyounouski, M. K. / Ma, C -M et al. | 2009
- 503
-
Imaging motion with a 4-row CT scanner (GE Light Speed RT)Kornhuber, C. / Mehnert, A. / Vordermark, D. et al. | 2009
- 507
-
Measurements of the Signal-to-Noise Ratio with “EPID QC Phantom®” and “epidSoft 2.0” from PTWLiebich, J. / Licher, J. / Scherf, C. / Moog, J. / Kara, E. / Ramm, U. et al. | 2009
- 511
-
E-IMRT: a web platform for the verification and optimization of radiation treatment plans.Pena, J. / Gonzalez-Castaño, D. M. / Gomez, F. / Gago-Arias, A. / González-Castaño, F. J. / Rodríguez-Silva, D. A. / González, D. / Pombar, M. / Sánchez, M. / Portas, B. C. et al. | 2009
- 515
-
Tumor Alignment between 4DCT and 4D Cone Beam CT for Irregular Respiratory Patient - a Phantom StudyDing, C. / Huang, L. / Papiez, L. / Timmerman, R. / Solberg, T. et al. | 2009
- 519
-
Analysis of Error Detection in EPID-Based IMRT Pre-Treatment QAGordon, J. J. / Gardner, J. / Wang, S. / Siebers, J. V. et al. | 2009
- 523
-
Improving the accuracy of entrance dosimetry measurements for dose modelingSiebers, J. V. / Ververs, J. D. / McEwen, M. R. et al. | 2009
- 527
-
Evaluation of the Twin Chamber Signal Ratio, a Physical Estimate of the Low- Energy Photon Contribution to Dose within Radiotherapy FieldsChofor, N. / Harder, D. / Willborn, K. / Rühmann, A. / Poppe, B. et al. | 2009
- 530
-
Uncertainties of RBE in treatment planning for ion beam tumor therapy: Experimental and modeling aspectsFriedrich, T. / Elsässer, T. / Scholz, M. et al. | 2009
- 533
-
Efficacy of Cummulative Biological Doses at Various Points of Lymphatic Trapzoid Using Microselectron HDRPassi, Kamlesh / Zakhmi, J. V / Vashistha, R. / Singh, Bikramjit / Mittal, Meenakshi / Gupta, S. J. / Kehwar, T. S. et al. | 2009
- 535
-
Obtaining information on intra-fraction prostate displacement in radiotherapy determined from pre- and post-treatment kV imagingKron, T. / Thomas, J. / Fox, C. / Thompson, A. / Owen, R. / Herschtal, A. / Haworth, A. / Tai, KH. / Foroudi, F. et al. | 2009
- 539
-
The Investigation of Dosimetric Reduction on Organs at Risk in Nasopharyngeal Carcinoma for Static IMRT PlanningZhu, Jian / Liu, Min / Yin, Yong et al. | 2009
- 540
-
Dose calculations for clinical proton broad beams by GEANT4Akagi, T. / Yamashita, T. / Suga, D. / Murakami, M. / Hishikawa, Y. / Aso, T. / Kimura, A. / Sasaki, T. et al. | 2009
- 544
-
Use of Nanoparticles in Brachytherapy – An Alternative for Enhancing Doses in Cancer TreatmentGual, Maritza Rodríguez / Cardona, Caridad M. Alvarez / González, Landy Y. Castro / García, Jesús Rosales et al. | 2009
- 548
-
Improvement in dose homogeneity in a patient with sinonasal cancer using nasal accessoryPark, Soah / Kang, Sei-Kwon / Cheong, Kwang-Ho / Hwang, Tai-Jin / Kim, Kyoung-Joo / Bae, Hoonsik et al. | 2009
- 551
-
Implementations and first measurements with Delta4 at the TomoTherapyKampfer, S. / Schill, S. / Kneschaurek, P. et al. | 2009
- 555
-
Dedicated treatment planning system for the evaluation of the doses delivered to the whole patient body during radiotherapyDiallo, I. / Alziar, I. / Perret, N. / Bridier, A. / Bonniaud, G. / Chavaudra, J. / Ruaud, J. B. / Rousseau, V. / Kafrouni, H. / Lefkopoulos, D. et al. | 2009
- 559
-
Dose Verification of Critical Structures in Gamma Knife Radio Surgery of Pituitary AdenomaPendse, A. M. / Deshpande, Sudesh / Basu, Mahua / Vandana, S. / Misra, B. K. et al. | 2009
- 562
-
Beam Angle Optimization in Particle Therapy with OptiCSpeer, S. / Karg, J. / Schmidt, M. / Müller, R. G. et al. | 2009
- 566
-
Camera-based independent couch height verification in radiation oncologyKusters, J. / Louwe, R. / Claessen, R. / Seters, R. / Huizenga, H. et al. | 2009
- 569
-
4D-CT reconstruction based on body volume changeShu-Xu, Z H A N G / Lin-hong, Z H O U / Hu, Yu / Shi-Qin, Wang / Guang-jie, C H E N / Sheng-qu, L I N / Hai-nan, Z H A N G et al. | 2009
- 573
-
Monte-Carlo calculation of beam quality correction factors and comparison with experimental measurementsHartmann, G. H. / González-Castaño, D. M. / Sánchez-Doblado, F. / Gómez, F. / Kapsch, R. -P. / Capote, R. / Pena, J. et al. | 2009
- 577
-
Localization of high dose rate 192Ir source during brachytherapy treatment using silicon detectorsBatič, M. / Burger, J. / Cindro, V. / Kramberger, G. / Mandić, I. / Mikuž, M. / Studen, A. / Zavrtanik, M. et al. | 2009
- 581
-
Systematic Studies on the Beam Stability and the Transient Effect of a Siemens ONCOR Impression AcceleratorWieczorkowski, L. / Hoinkis, C. / Lehmann, D. / Enghardt, W. et al. | 2009
- 585
-
The Dosimetric Study of Static MLC Based Electronic Tissue Compensation using In-house Leaf Sequencing SoftwareRabi Raja, Singh I. / Annlin, J. Shiju / Godson, Henry Finlay / Paul Ravindran, B. et al. | 2009
- 589
-
The Monte Carlo Code MCPTV- Dose Calculation in Radiation Therapy with Carbon IonsKarg, J. / Speer, S. / Schmidt, M. / Müller, R. G. et al. | 2009
- 591
-
Interfractional Variations of Shape and Impact on Dose of Organs at Risk in Head and Neck Cancer Patients during Helical TomotherapyDuma, M. N. / Kampfer, S. / Jacob, V. / Wilkens, J. J. / Schuster, T. / Molls, M. / Geinitz, H. et al. | 2009
- 595
-
Experimental determination of the radial dose distribution in high gradient regions from a low dose rate iridium-192 wire sources using EPR imagingKolbun, N. / Levêque, P. / Abboud, F. / Vynckier, S. / Gallez, B. et al. | 2009
- 599
-
Dose Evaluation in Medulloblastoma CancersTazehmahalleh, F. Ebrahimi / Poppe, B. / Rühemann, A. / Welzel, J. / Horn, W. / Raub, M. / Willborn, K. et al. | 2009
- 601
-
Output measurement for small field photon beams in a sandwiched phantomSrivastava, R. P. / Olteanu, A. M. L / Ebongue, A. N / Bekaert, B. / Wagter, C et al. | 2009
- 604
-
Comparison of Monte Carlo Dose Calculation with Advanced Kernel Methods in External Photon Beam Treatment PlanningFotina, I. / Kroupa, B. / Georg, D. et al. | 2009
- 608
-
Verification of head & neck IMRT-plans by Monte Carlo simulationSchoenenberg, D. / Rickhey, M. / Dobler, B. / Goetzfried, T. / Bogner, L. et al. | 2009
- 612
-
Optimization of Catheter Position and Dwell Time in Prostate HDR Brachytherapy using HIPO and Linear ProgrammingKarabis, A. / Belotti, P. / Baltas, D. et al. | 2009
- 616
-
Real-Time Compensation of Target Motion with a Dynamic Multileaf CollimatorTacke, M. B. / Nill, S. / Oelfke, U. et al. | 2009
- 620
-
An Augmented Reality Application for Patient Positioning and Monitoring in RadiotherapyTalbot, J. / Meyer, J. / Watts, R. / Grasset, R. et al. | 2009
- 624
-
STATIONARY-GANTRY TOMOSYNTHESIS SYSTEM FOR ON-LINE IMAGE GUIDANCE IN RADIATION THERAPY BASED ON A 52-SOURCE COLD CATHODE X-RAY TUBEMaltz, Jonathan S. / Fuerst, Jens / Paidi, Ajay / Fadler, Franz / Bani-Hashemi, Ali R. / Sprenger, Frank et al. | 2009
- 628
-
Dosimetric Errors of TPS Calculations without Correction for Heterogeneity - A Study Using CIRS Thorax PhantomPawiro, S. A. / Sugiyantari / Wibowo, W. E. / Cheung, K. Y. / Soejoko, D. S. et al. | 2009
- 631
-
Adjustable Prescription Dose: A New Strategy to Improve IMRT Treatment PlanningLougovski, P. / LeNoach, J. E. / Ma, Y. / Zhu, L. / Xing, L. et al. | 2009
- 635
-
Segmented Deformable Registration for Improved Modeling of the LungsXie, Y. Q. / Liu, W. / Chao, M. / Bao, S. L. / Xing, L. et al. | 2009
- 638
-
Basic investigation of boron neutron capture therapy (BNCT) using novel boron agents and accelerator based neutron sourceSakai, M. / Fujimoto, N. / Ishii, K. / Murata, I. / Lee, C. M. / Kaneda, Y. / Nakamura, H. / Awazu, K. et al. | 2009
- 642
-
Robotic Phantom to Simulate Patient Breathing MotionThomas, Nihal Danie / Ravindran, Paul B et al. | 2009
- 645
-
Improved simulation of small electron fields for external beam radiation therapyO’Shea, T. P. / Sawkey, D. L. / Foley, M. J. / Faddegon, B. A. et al. | 2009
- 649
-
The Feasibility of Goggle Monitor for Respiratory Biofeedback of Patient to Reduce Correlation Error Using Real-Time Tumor Tracking SystemHuh, Hyun / Choi, Sang Hyoun / Kim, WooChul / Kim, Hun Jeong / Kim, Seong Hoon / Ji, Young Hoon / Choi, Jinho / Cho, Sam Ju / Im, Sang Wook / Shin, Dong oh et al. | 2009
- 652
-
Improved Techniques to Assign Accurate Phase Information Of Respiratory Signals for 4D CT ReconstructionPark, H. J. / Yoon, J. W. / Jung, W. G. / Song, J. Y. / Suh, T. S. et al. | 2009
- 656
-
Predicting Response in Lung Cancer from FDG-PET Uptake CharacteristicsNaqa, I. / Vaidya, M. / Apte, A. / Dehdashti, F. / Deasy, J. O. / Bradley, J. D. et al. | 2009
- 660
-
Determination of Dose Escalation Region in Malignant Brain tumors for Radiation Treatment Planning Based on Apparent Diffusion Coefficient MapPark, J. Y / Ahn, K. J / Woo, D. C / Lee, J. W / Kim, J. Y / Jung, W. K / Choe, B. Y / Suh, T. S et al. | 2009
- 664
-
Backscatter Factors for a Clinical 6 MeV Electron BeamChoi, Chang Heon / Eufemio, Alvin / Ye, Sung-Joon / Pareek, Prem et al. | 2009
- 667
-
Fast optimization of non-coplanar beam angle sets for intensity modulated radiation therapyBangert, M. / Oelfke, U. et al. | 2009
- 671
-
Can a Commercially Available TPS Be Used to Develop VMAT Solutions?Rowbottom, C. G. / Boylan, C. J. / Golby, C. / Atherton, S. / Smith, S. / Mackay, R. I. et al. | 2009
- 674
-
Considering marker visibility during leaf sequencing for segmental intensity-modulated radiation therapyZhao, Bo / Dai, Jianrong et al. | 2009
- 678
-
Tomotherapy Quality Assurance (TQA): A Fast and Comprehensive Software ToolCoevoet, M. / Denis, J. M. / Cravens, B. / Krumbach, T. / Figueredo, J. / Olivera, G. / Vynckier, S. et al. | 2009
- 679
-
Monte Carlo Based Suggestion of the Best Choice for Material of a Multileaf Collimator (MLC) and the Required ThicknessHariri, S. / Shahriari, M. et al. | 2009
- 683
-
BANG-3® polymer gel dosimetry in CyberknifeKang, Young-nam / Jang, Jisun / Choi, Byung-Ock / Jang, Hong-Suk / Jung, Ji-Young / Shin, Hun-Joo / Seo, Jae-Hyuk / Choi, Ihl-Bohng / Lee, Dong-Joon / Kwon, Soo-Il et al. | 2009
- 686
-
Production of Ac-225 with Cyclotrons for Generating Bi-213 for Targeted Alpha TherapyChaudhri, M. Anwar / Chaudhri, M. Nasir / Nadeem, Qamar / Jabbar, Qaiser et al. | 2009
- 688
-
Development of customized program to generate 2D dose map with high resolution for 120 Leaf MLCCho, Woong / Chung, Jin beom / Jung, Won-Gyun / Park, Jeong-Hoon / Suh, Tae-Suk et al. | 2009
- 692
-
Development of an image-guided radiation therapy device for precise irradiation of small animal tumorsThute, Prasad / Khaless, Arian / Hietschold, Volker / Enghardt, Wolfgang et al. | 2009
- 696
-
A finger leaf design for dual layer MLCsDai, Jianrong / Cui, Weijie et al. | 2009
- 700
-
Head scatter factor calculation considering characteristics of scattered photonMiyashita, Hisayuki / Hatanaka, Shogo / Fujita, Yukio / Myojyoyama, Atsushi / Saitoh, Hidetoshi et al. | 2009
- 704
-
Monte Carlo Dose Calculation using GPU-Based parallel processingMyojyoyama, Atsushi / Saitoh, Hidetoshi et al. | 2009
- 708
-
Different simple Models for Optimizing Convergent Beam Multiple Field Irradiation for Stereotactic Treatment TechniquesHodapp, N. / Wiehle, R. / Röhner, F. / Ioan, O. / Koth, H. -J. / Passmann, M. et al. | 2009
- 711
-
Sparing of critical organs in radiotherapy of mediastinal lymphomaSchill, S. / Kampfer, S. / Hansmeier, B. / Nieder, C. / Geinitz, H. et al. | 2009
- 714
-
Evaluation of dosimetric accuracies of gated step-and-shoot IMRT using Dynalog dataCheong, Kwang-Ho / Kang, Sei-Kwon / Kim, Kyoung-Joo / Park, SoAh / Hwang, Tae-Jin / Bae, Hoonsik / Lee, MeYeon / Oh, Do-Hoon / Suh, Tae-Suk et al. | 2009
- 717
-
Linear Accelerator Photon Beam Interaction with the Virtual Physiological HumanMaalej, Nabil M. / Mwidu, Umar M. / Jalal, Bilal / Naqvi, Akhtar A. et al. | 2009
- 721
-
Investigation into the Pinnacle SmartArc Module for VMAT PlanningRowbottom, C. G. / Golby, C. / Atherton, S. / Mackay, R. I. et al. | 2009
- 725
-
Why still Multibeam Tomotherapy?Achterberg, N. / Müller, R. G. / Forster, J. / Forster, R. / Müller, T. et al. | 2009
- 728
-
Comparison of beam data using diode and ion chamber in small field of CyberKnifeJang, Jisun / Kang, Young-Nam / Shin, Hun-Joo / Seo, Jae-Hyuk / Kim, Moon-Chan / Lee, Dong-Joon / Kwon, Soo-Il et al. | 2009
- 731
-
Characterization and Monte Carlo Simulation of Low- and High-Perturbation in-vivo Diode Dosimeters for 9 MV X-RaysMosleh-Shirazi, M. A. / Shahbazi-Gahrouei, D. / Karbasi, S. / Monadi, S. et al. | 2009
- 735
-
Development of an Optimized Pencil Beam Algorithm for Radiation TherapySiggel, Martin / Nill, Simeon / Oelfke, Uwe et al. | 2009
- 739
-
How Much Target Average Positions in Thorax Region Change Daily?Wang, Lu / Feigenberg, Steve / Fan, James / Jin, Lihui / Chen, Lili / Ma, Charlie et al. | 2009
- 740
-
Accuracy evaluation of using MV EPID and / or integrated kV imaging system to locate 3D positions of internal fiducial markers using a Calypso systemMao, Weihua / Foster, Ryan / Solberg, Timothy et al. | 2009
- 744
-
In-hospital neutron autoradiography for Boron Neutron Capture Therapy applicationsMattera, A. / Bolognini, D. / Hasan, S. / Prest, M. / Vallazza, E. / Giannini, G. / Cappelletti, P. / Frigerio, M. / Gelosa, S. / Monti, A. F. et al. | 2009
- 748
-
Introduction of a Breath Gating System in a Clinical EnvironmentHaack, H. / Kunth, W. / Kollhoff, R. / Rühmann, A. / Poppe, B. / Willborn, K. et al. | 2009
- 750
-
Computerized Treatment Planning Directives for Adaptive Radiation Therapy ManagementMcShan, D. L. / Chen, X. / Kessler, M. L. / Keranen, W. M. / Fraass, B. A. et al. | 2009
- 754
-
Fast range compensation inside the beam line for beam tracking in particle therapyChaudhri, N. / Saito, N. / Bert, C. / Steidl, P. / Franczak, B. / Durante, M. / Rietzel, E. / Schardt, D. et al. | 2009
- 758
-
Optimal delivery of DMLC Arc TherapyPapiez, Lech / Rangaraj, Dharanipathy et al. | 2009
- 762
-
Small Photon Field Dosimetry using GelRavindran, Paul B et al. | 2009
- 765
-
A Method for Evaluation of Target Point Correction in Fractionated RadiotherapyGiske, K. / Stoll, A. / Stoiber, E. M. / Bendl, R. et al. | 2009
- 769
-
Performance of patient specific margins derived using a Bayesian statistical methodHerk, M. / Witte, M. / Remeijer, P. et al. | 2009
- 772
-
Combination of External/Image-Based Detection of Respiratory Induced Motion and Adaption with a Gating MechanismSchwarz, M. / Nill, S. / Bendl, R. et al. | 2009
- 776
-
How Regular Motion Pattern and Patient Individual Respiration Curves Affect Contour and Volume of Geometric Structures in a 4D CTBlock, A. / Noertersheuser, T. / Mewes, A. / Bauer, R. et al. | 2009
- 780
-
Comparison of Daily Online Ultrasound and MV-CBCT Localization Data for Post Prostatectomy Cancer Patients and Implications for PTV Margin ExpansionMiften, Moyed / Gayou, Olivier et al. | 2009
- 784
-
Comparison of Localization Techniques for Prostate RadiotherapyFoster, R. D. / Papiez, E. / Solberg, T. D. et al. | 2009
- 788
-
Optimized Spinal Cord Contour Propagation for Fractionated Radiation Therapy PlanningStoll, A. / Giske, K. / Stoiber, E. M. / Bendl, R. et al. | 2009
- 792
-
A comprehensive quality assurance Program for radiotherapy using TLD : The Algerian ExperienceArib, M. / Medjadj, T. / Dari, F. / Bali, M. S. / Khoudri, S. / Yennoune, A. / Hattali, B. et al. | 2009
- 794
-
Optimization of an external beam radiotherapy treatment using GAMOS/Geant4Arce, P. / Lagares, J. I. / Perez-Astudillo, D. / Apostolakis, J. / Cosmo, G. et al. | 2009
- 798
-
Simplified Geometrical Model for Treatment Margins Evaluation in Brain RadiosurgeryBallesteros-Zebadúa, P. / Garcia-Garduño, O. A. / Gutiérrez-Aceves, G. A. / Moreno-Jiménez, S. / Celis, M. A. / Lárraga-Gutiérrez, J. M. et al. | 2009
- 802
-
Characterization of a PMMA embedded extrapolation chamber in 60Co gamma beamsarib, M. / mostefai, A. kouadri / medjadj, T. / tilmati, M. / boudouma, Y. et al. | 2009
- 805
-
Comparison of different evaluation programs for the verification of patient irradiations with tomotherapyCremers, F. / Glessmer, S. / Albers, D. / Bartels, A. / Schönborn, T. / Thom, E. / Todorovic, M. et al. | 2009
- 809
-
Monte Carlo simulation of novel procedures for highly conformal percutaneous radiation with keV-photons for tumor treatment in skin proximityPetersheim, M. / Hesser, J. / Wenz, F. et al. | 2009
- 813
-
Monte Carlo benchmarking of a CCC-based treatment planning system in case of irregularly shaped fieldsOlteanu, A. M. L. / Srivastava, R. P. / Reynaert, N. / Wagter, C. / Neve, W. et al. | 2009
- 817
-
Radioiodine Biokinetics and Dosimetry in Patients with Differentiated Thyroid Carcinoma and Renal InsufficiencyVeloza, L. S. / Rojas, L. J. / Stabin, M. G. / Garavito, G. / Llamas, A. E. et al. | 2009
- 821
-
Developments in MRI-based radiation treatment planningStanescu, T. / Kirkby, C. / Wachowicz, K. / Fallone, B. G. et al. | 2009
- 825
-
Electron beam dosimetry in heterogeneous phantoms using MAGIC normoxic polymer gelAsl, R. Ghahraman / Bolouri, B. / Nedaie, H. / Arbabi, A. et al. | 2009
- 829
-
Dosimetric Testing of a New Release of 3D Treatment Planning System with the IAEA-TECDOC-1540Kom, O. M. Makam / Licht, N. et al. | 2009
- 833
-
Absorbed Dose Reference for LDR Brachytherapy the LNE-LNHB ApproachAubineau-Lanièce, I. / Lucas, P. Avilés / Bordy, J. M. / Chauvenet, B. / Cutarella, D. / Douysset, G. / Gouriou, J. / Plagnard, J. et al. | 2009
- 840
-
Image enhancement techniques allowing observation of intra-fractional motion in IMRT treatment for prostate carcinomaHeuvel, F. / Slagmolen, P. / Larrew, J. et al. | 2009
- 844
-
DIRART – A Software Suite for Deformable Image Registration and Adaptive Radiotherapy ResearchYang, Deshan / Naqa, Issam / Aditya, Apte / Wu, Yu / Goddu, Murty / Mutic, Sasa / Deasy, Joseph O. / Low, Daniel A. et al. | 2009
- 848
-
An Alternative Approach to Inverse Planning Optimization: Applying the Projection Theorem to Concave and Convex PTVs for VMAT DeliveryHoegele, W. / Loeschel, R. / Zygmanski, P. et al. | 2009
- 852
-
3 Years of Data Collection and Analysis of Film Flatness and Symmetry Using Vidar/RIT Software from Different Centers Nation WideMovahed, Allen et al. | 2009
- 854
-
Small Field MV Photon DosimetryAspradakis, Maria Mania et al. | 2009
- 855
-
Virtual Spirometry: Utilizing an abdominal bellows system for quantitatively gating in 4D CT acquisitionWerner, R. / White, B. / Schwenke, M. / Handels, H. / Lu, W. / Low, D. A. et al. | 2009
- 859
-
In vivo dosimetry for patient specific quality assurance in aperture based IMRTAlfonso-Laguardia, R. / Vega-Hernández, M. et al. | 2009
- 863
-
Validation of a Biplanar Diode Array Dosimeter for Helical Tomotherapy Delivery QAFeygelman, V. / Opp, D. / Javedan, K. / Saini, A. J. / Zhang, G. et al. | 2009
- 867
-
Comparison between Clinically Used Irregular Fields Shaped by Cerrobend Blocks and by Multileaf Collimator Using a Clarkson Sector Integration Computer ProgramCruzet, R. U. et al. | 2009
- 871
-
Evaluation of 3-D Treatment Plans Using Physical and Motorised Enhanced Dynamic WedgesSathiyan, S. / Ravikumar, M. et al. | 2009
- 873
-
Integral Dose in Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, and Helical TomotherapyYang, Ruijie / Xu, Shouping / Wang, Junjie et al. | 2009
- 875
-
Extension of Electron Monte Carlo Dose Calculation in Eclipse to Siemens Linear AcceleratorsFix, M. K. / Cygler, J. E. / Vandervoort, E. / Karle, H. / Tertel, J. / Frei, D. / Volken, W. / Born, E. J. / Manser, P. et al. | 2009
- 878
-
Current Status of the HIBMC, Providing Particle Beam Radiation Therapy for More Than 2,600 Patients, and the Prospects of Laser-Driven Proton RadiotherapyMurakami, M. / Demizu, Y. / Niwa, Y. / Nagayama, S. / Maeda, T. / Baba, M. / Miyawaki, D. / Terashima, K. / Arimura, T. / Mima, M. et al. | 2009
- 883
-
Monte Carlo Study of Depth Dose Calculation for Low Energy Clinical Electron BeamsJafari, H. / Chopan, H. / Taleei, R. et al. | 2009
- 887
-
Setup Variations and Tumor Margins Using the ExacTrac X-Ray 6D in Prostate RadiotherapyKim, J. Y. / Chang, S. K. / Shin, H. S. et al. | 2009
- 890
-
Useful Techniques for Tomotherapy Treatment PlanningGurvich, V. / Feygelman, V. et al. | 2009
- 893
-
Optimization of Radial Dose Function for Varian Ir-192 Brachytherapy Source Model VS2000Outif, A. M. / Elawadi, A. A. et al. | 2009
- 897
-
On the Use of a Light Ion Kernel for Biologically Optimized Adaptive Inverse Treatment PlanningKempe, J. et al. | 2009
- 900
-
Range, Setup and Dose Calculation Errors in IMPT and Their InterrelationUnkelbach, J. / Soukup, M. / Alber, M. / Bortfeld, T. et al. | 2009
- 904
-
Motion-Weighted Dose-Volume Histograms – A Novel Approach to 4D Treatment PlanningZhang, G. G. / Feygelman, V. / Stevens, C. / Li, W. / Dilling, T. et al. | 2009
- 908
-
Assessing Correlations between the Spatial Distribution of Dose to the Rectal Wall and Late Rectal Toxicity after Prostate RadiotherapyBuettner, F. / Gulliford, S. L. / Partridge, M. / Sydes, M. R. / Dearnaley, D. P. / Webb, S. et al. | 2009
- 912
-
Design and Physical Properties of an IrisTM Collimator for Robotic RadiosurgeryKilby, W. / Echner, G. G. / Lee, M. / Earnst, E. / Sayeh, S. / Rhein, B. / Lang, C. / Maurer, C. R. Jr. / Schlegel, W. et al. | 2009
- 916
-
Evaluation of the Clinical Utility of an IrisTM Collimator Combined with a Sequential Optimization Algorithm for Robotic RadiosurgeryKilby, W. / Schlaefer, A. / Dooley, J. / Blanck, O. / Lessard, E. / Maurer, C. R. Jr. et al. | 2009
- 920
-
A Quality Assurance Tool Based on kV- and MV-Image Analysis for a Linear Accelerator Including an Integrated IGRT SystemWinkler, P. / Hofer, C. / Stollberger, R. et al. | 2009
- 924
-
MRI and CT Slice Thickness Evaluation by Computerized Dedicated ProceduresVermiglio, G. / Testagrossa, B. / Acri, G. / Tripepi, M. G. / Marino, S. / Bramanti, P. et al. | 2009
- 928
-
Re-planning for Compensator-Based IMRT with Original CompensatorsZhang, G. / Feygelman, V. / Stevens, C. / Li, W. / Leuthold, S. / Springett, G. / Hoffe, S. et al. | 2009
- 932
-
Single-Pulse-Resolved Dosimetry with Miniaturized Detectors in TeletherapyIllemann, J. et al. | 2009
- 936
-
The evaluation of therapeutic effect of trastuzumab labeled 177lu in breast cancer cell lineRasaneh, S. / Rajabi, H. / Babaei, M. H. / Johari, F. / Sheibani, S. / Salehi, H. / Shafiei, M. / Tavakoli, Y. / Mazidi, M. / Mirfallah, H. et al. | 2009
- 938
-
SURE-LET and BLS-GSM wavelet-based denoising algorithms versus linear Local Wiener Estimator in Radiotherapy portal image denoising.González-López, A. / Morales-Sánchez, J. / Verdú-Monedero, R. / Larrey-Ruiz, J. / Sancho-Gómez, J. L. / Tobarra-González, B. et al. | 2009
- 941
-
Learning from Incidents in Radiation TreatmentClark, B. G. / Brown, R. J. / Ploquin, J. / Kind, A. / Grimard, L. et al. | 2009
- 945
-
Combined Dose Distribution for the External Beam Whole Breast Irradiation and MammoSite Breast Brachytherapy: Monte Carlo InvestigationBensaleh, S. / Bezak, E. / Pham, T. et al. | 2009
- 949
-
In-vivo Proton Beam Shaping Using Static Magnetic Field for Cancer TherapySardari, D. / Hosseini-hamid, M. / Saeidi, P. et al. | 2009
- 952
-
A Preliminary Study on Development of QA System for Stereotactic Head Frame and Its Reliability and AccuracyOh, S. / Kim, J. Y. / Suh, T. S. / Hong, J. Y. / Kim, S. et al. | 2009
- 955
-
Performance and Clinical Trial in vivo of a Scintillation Dosimeter in BrachytherapyCartwright, L. E. / Nagory, M. / McKenzie, D. R. / Suchowerska, N. et al. | 2009
- 959
-
Algorithm Development of Designing a Patient-Specific Block for MC-Based Dose Calculation in Electron Beam Therapy for Breast CancerJung, Sang Hoon / Park, Sung Ho / Choi, Ik Soo / Baek, Geum Mun / Choi, Eun Kyung / Kim, Jong Hoon / Lee, Sang-wook / Song, Si Yeol / Do Ahn, Seung et al. | 2009
- 962
-
An Air Core Scintillation Dosimeter for Megavoltage External Beam Dosimetry: Experimental ResultsLambert, J. / Yin, Y. / McKenzie, D. R. / Law, S. / Ralston, A. / Suchowerska, N. et al. | 2009
- 966
-
An Air Core Cerenkov Free Scintillation Dosimeter: Monte Carlo Simulation for External Beam Radiation TherapyNaseri, P. / Lambert, J. / McKenzie, D. R. / Suchowerska, N. et al. | 2009
- 970
-
Simulation Study on Coverage of Tumor Motion Accordance with the Scanning Time in Slow-Scan CTPark, Chun-Joo / Park, Sung Ho / Kwak, Jungwon / Choi, Eun Kyung / Kim, Jong Hoon / Lee, Sang-Wook / Song, Si Yeol / Yoon, Sang Min / Do Ahn, Seung et al. | 2009
- 973
-
Calibration of Therapy-level Dosimeters in Japan by Association for Nuclear Technology in Medicine (ANTM)Sakata, S. / Akiyama, Y. / Kusano, Y. / Takase, E. / Yajima, K. / Uesaka, S. / Mizuno, H. / Fukumura, A. / Tanaka, T. et al. | 2009
- 977
-
Out-of-Treatment Room Set-Up for Patient Positioning in External Beam RadiotherapyWeber, L. / Westerlund, K. / Näslund, I. / Dahlin, H. et al. | 2009
- 981
-
Application of 2 Step IMRT to Spinal Tumors: A Preliminary Retrospective Planning Study Comparison with Classical IMRTGainey, M. B. / Bratengeier, K. / Flentje, M. et al. | 2009
- 985
-
Comparison of Two different Methods for describing the geometry of a Voxelized Anthropomorphic Phantom in Radiotherapy Treatment PlansAbella, V. / Miro, R. / Juste, B. / Verdu, G. et al. | 2009
- 989
-
Measuring system for testing the mechanical isocenter accuracy of medical linear acceleratorsCasar, B. / Cugura, D. / Carot, I. Mendez / Vojvodic, I. / Rebersek, S. et al. | 2009
- 993
-
Validation of the SUV values calculation in the iPlan 4.0 Treatment Planning System (BrainLAB)Jacob, V. / Kneschaurek, P. / Souvatzoglou, M. / Astner, S. T. / Bundschuh, R. A. / Busch, R. / Grosu, A. -L. et al. | 2009
- 996
-
New system for TBI with translation method at the Institute of Oncology LjubljanaCasar, B. / Vojvodic, I. / Robar, V. / Smrdel, U. / Carot, I. Mendez et al. | 2009
- 998
-
Estimation of Free Electron Fraction Value p for a Parallel-Plate Ionization Chamber in High Dose Per Pulse IORT Electron BeamsLiuzzi, R. / Salvatore, M. / Cella, L. et al. | 2009
- 1001
-
VMC++: Validation of the Monte Carlo code for low energiesTerribilini, D. / Fix, M. K. / Frei, D. / Volken, W. / Manser, P. et al. | 2009
- 1004
-
Dose Distribution Depending on the Number of Control Points in Forward-Planned Intensity-Modulated Radiation Therapy for Breast CancerHwang, Taejin / Kang, Sei-Kwon / Cheong, Kwang-Ho / Park, Soah / Lee, Meyeon / Kim, Kyoung-Joo / Oh, Do-Hoon / Bae, Hoonsik / Suh, Tae-Suk et al. | 2009
- 1008
-
Method of Combined Proton-Photon Radiation Therapy of Prostate CancerKhmelevsky, Evgeni V. / Kharchenko, V. P. / Mel’nik, Yu. D. / Kancheli, Irina N. / Klenov, Gennady I. / Lomanov, Michael F. / Lyulevich, Valentin I. / Pokhvata, Valery P. / Ryazantsev, Oleg B. / Khoroshkov, Vladimir S. et al. | 2009
- 1009
-
Conversion of Greyscale Intensity Values from CBCT Images Acquired on Elekta XVI to HU for Treatment Planning Dose CalculationsLa, S. / Ceberg, C. / Tomaszewicz, A. / Weber, Lars et al. | 2009
- 1012
-
Dosimetric Comparison between Helical Tomotherapy and Biologically Based IMRT Treatment Planning System for Selected CasesPloquin, N. P. / Bélec, J. G. / Clark, B. G. et al. | 2009
- 1016
-
Study of a CVD diamond detector for absorbed dose measurement in photon beams with small field sizesCaporali, C. / Conte, G. / Guerra, A. S. / Laitano, R. F. / Pimpinella, M. et al. | 2009
- 1020
-
Analysis of Dose Shifts induced by Organ Movements during Treatment with TomoTherapy using a Motion Phantom and GafChromic EBT FilmsGrohmann, C. / Werner, R. / Albers, D. / Cremers, F. et al. | 2009
- 1024
-
Tolerance of the Spinal Cord to Hypofractionated Radiotherapy Based on a Generalized Biological Effective Dose (gBED) ModelMa, L. / Sahgal, A. / Larson, D. A. et al. | 2009
- 1027
-
Reproducibility of neutron activated Sm-153 in tablets intended for human volunteer studiesYeong, C. H. / Blackshaw, P. E. / Ng, K. H. / Abdullah, B. J. J. / Blaauw, M. / Dansereau, R. J. / Perkins, A. C. et al. | 2009
- 1031
-
Sequential Optimization Scripts to Facilitate Treatment Planning for Robotic Radiosurgery Clinical Studies for Prostate and Lung CancersLessard, E. / Kilby, W. / Dooley, J. / Sims, C. / Schlaefer, A. / Blanck, O. / Maurer, C. R. Jr. et al. | 2009
- 1035
-
Comparative study between IBT or EBRT boost doses at organs at risk in Cervical Cancer treatmentPereira, A. / Pirraco, R. / Viterbo, T. / Gomes, L. / Borges, F. / Salgado, L. / Carvalho, L. / Trigo, L. / Lencart, J. et al. | 2009
- 1038
-
Beam Characterization for Step-and-Shoot IMRTBatel, V. P. / Figueira, A. R. / Carvalho, A. L. / Reis, T. et al. | 2009
- 1042
-
Assessment of Image Guidance Using kV Orthogonal Images and Cone Beam CT for Liver Stereotactic RadiosurgeryPark, Dong-wook / Kwak, Jungwon / Park, Sung Ho / Choi, Eun Kyung / Kim, Jong Hoon / Lee, Sang-wook / Song, Si Yeol / Yoon, Sang Min / Do Ahn, Seung et al. | 2009
- 1046
-
Dosimetric Effects of Gantry Angular Acceleration and Deceleration in Volumetric Modulated Radiation TherapySong, Y. / Zhang, P. / Obcemea, C. / Mueller, B. / Chandra, C. / Mychalczak, B. et al. | 2009
- 1051
-
Evaluation of Multileaf Collimator Effect on the Build-Up Dose Region Using Different Ionization ChambersMoreno, M. Zarza / Souto, A. C. / Teixeira, N. / Jesus, A. P. / Mora, G. et al. | 2009
- 1055
-
Standard Absorbed Dose to Water for HDR Brachytherapy Sources with Fricke DosimetryAlmeida, C. E. / Ochoa, R. / Austerlitz, C. / Coelho, M. / Gazineu, M. / Peixoto, J. G. / Pires, E. J. / Allison, R. R. / Mota, H. / Sibata, C. et al. | 2009
- 1057
-
Monoscopic Imaging for Intra-fraction Motion ManagementAgazaryan, N. / Tenn, S. / Selch, M. / Rehs, J. / Erbel, S. / Remmert, G. et al. | 2009
- 1060
-
Clinac Performance: Watching the First SecondsFigueira, A. R. / Batel, V. P. / Carvalho, A. L. / Reis, T. et al. | 2009
- 1063
-
Accelerated Dose Calculation Engine for Interstitial BrachytherapyChibani, Omar / Moftah, Belal / Ma, C. -M. Charlie et al. | 2009
- 1067
-
Updated Beam Parameters for Monte Carlo Simulation of Five Varian Megavoltage Photon Beams (4, 6, 10, 15 and 18 MV)Chibani, Omar / Moftah, Belal / Ma, Charlie et al. | 2009
- 1071
-
Single and Multibeam Dose Distribution for Treatment Planning of CancerJabeen, Rukhsana / Afzal, M. et al. | 2009
- 1074
-
Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC): Clinical UseHaken, R. K. / Marks, L. B. / Bentzen, S. M. / Constine, L. S. / Deasy, J. O. / Eisbruch, A. / Yorke, E. D. / Jackson, A. et al. | 2009
- 1075
-
The Lessons of QUANTEC (Quantitative Analysis of Normal Tissue Effects in the Clinic): Recommendations for Reporting and Gathering Data on Dose-Volume Dependencies of Treatment OutcomeJackson, A. / Marks, L. B. / Bentzen, S. M. / Eisbruch, A. / Yorke, E. D. / Haken, R. K. / Constine, L. S. / Deasy, J. O. et al. | 2009