Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. 132 (Englisch)
- Neue Suche nach: Brock, Kristy K.
- Neue Suche nach: Mutic, Sasa
- Neue Suche nach: McNutt, Todd R.
- Neue Suche nach: Li, Hua
- Neue Suche nach: Kessler, Marc L.
- Neue Suche nach: Brock, Kristy K.
- Neue Suche nach: Mutic, Sasa
- Neue Suche nach: McNutt, Todd R.
- Neue Suche nach: Li, Hua
- Neue Suche nach: Kessler, Marc L.
In:
Medical Physics
;
44
, 7
;
e43-e76
;
2017
- Aufsatz (Zeitschrift) / Elektronische Ressource
-
Titel:Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. 132
-
Beteiligte:Brock, Kristy K. ( Autor:in ) / Mutic, Sasa ( Autor:in ) / McNutt, Todd R. ( Autor:in ) / Li, Hua ( Autor:in ) / Kessler, Marc L. ( Autor:in )
-
Erschienen in:Medical Physics ; 44, 7 ; e43-e76
-
Verlag:
-
Erscheinungsdatum:01.07.2017
-
Format / Umfang:34 pages
-
ISSN:
-
DOI:
-
Medientyp:Aufsatz (Zeitschrift)
-
Format:Elektronische Ressource
-
Sprache:Englisch
-
Schlagwörter:
-
Datenquelle:
Inhaltsverzeichnis – Band 44, Ausgabe 7
Zeige alle Jahrgänge und Ausgaben
Die Inhaltsverzeichnisse werden automatisch erzeugt und basieren auf den im Index des TIB-Portals verfügbaren Einzelnachweisen der enthaltenen Beiträge. Die Anzeige der Inhaltsverzeichnisse kann daher unvollständig oder lückenhaft sein.
- 3371
-
The use of gadolinium‐based contrast agents should be discontinued until proven safeBranch, Stacy Matthews / Tweedle, Michael F. / Orton, Colin G. et al. | 2017
- 3375
-
Trajectory optimization in radiotherapy using sectioning (TORUS)Locke, Christopher Barry / Bush, Karl Kenneth et al. | 2017
- 3393
-
Rapid acceptance testing of modern linac using on‐board MV and kV imaging systemsYaddanapudi, Sridhar / Cai, Bin / Harry, Taylor / Dolly, Steven / Sun, Baozhou / Li, Hua / Stinson, Keith / Noel, Camille / Santanam, Lakshmi / Pawlicki, Todd et al. | 2017
- 3407
-
Validation of biomechanical deformable image registration in the abdomen, thorax, and pelvis in a commercial radiotherapy treatment planning systemVelec, Michael / Moseley, Joanne L. / Svensson, Stina / Hårdemark, Björn / Jaffray, David A. / Brock, Kristy K. et al. | 2017
- 3418
-
Functional lung avoidance and response‐adaptive escalation (FLARE) RT: Multimodality plan dosimetry of a precision radiation oncology strategyLee, Eunsin / Zeng, Jing / Miyaoka, Robert S. / Saini, Jatinder / Kinahan, Paul E. / Sandison, George A. / Wong, Tony / Vesselle, Hubert J. / Rengan, Ramesh / Bowen, Stephen R. et al. | 2017
- 3430
-
A priori patient‐specific collision avoidance in radiotherapy using consumer grade depth camerasCardan, Rex A. / Popple, Richard A. / Fiveash, John et al. | 2017
- 3437
-
Technical Note: Is bulk electron density assignment appropriate for MRI‐only based treatment planning for lung cancer?Prior, Phil / Chen, Xinfeng / Gore, Elizabeth / Johnstone, Candice / Li, X. Allen et al. | 2017
- 3444
-
Contrast‐enhanced ultrasound imaging in vivo with laser‐activated nanodropletsYoon, Heechul / Yarmoska, Steven K. / Hannah, Alexander S. / Yoon, Changhan / Hallam, Kristina A. / Emelianov, Stanislav Y. et al. | 2017
- 3450
-
A fast, noniterative approach for accelerated high‐temporal resolution cine‐CMR using dynamically interleaved streak removal in the power‐spectral encoded domain with low‐pass filtering (DISPEL) and modulo‐prime spokes (MoPS)Kawaji, Keigo / Patel, Mita B. / Cantrell, Charles G. / Tanaka, Akiko / Marino, Marco / Tamura, Satoshi / Wang, Hui / Wang, Yi / Carroll, Timothy J. / Ota, Takeyoshi et al. | 2017
- 3464
-
Noise reduction and functional maps image quality improvement in dynamic CT perfusion using a new k‐means clustering guided bilateral filter (KMGB)Pisana, Francesco / Henzler, Thomas / Schönberg, Stefan / Klotz, Ernst / Schmidt, Bernhard / Kachelrieß, Marc et al. | 2017
- 3483
-
Variations in the functional visual field for detection of lung nodules on chest computed tomography: Impact of nodule size, distance, and local lung complexityEbner, Lukas / Tall, Martin / Choudhury, Kingshuk Roy / Ly, Donald L. / Roos, Justus E. / Napel, Sandy / Rubin, Geoffrey D. et al. | 2017
- 3491
-
Theoretical investigation of the noise performance of active pixel imaging arrays based on polycrystalline silicon thin film transistorsKoniczek, Martin / Antonuk, Larry E. / El‐Mohri, Youcef / Liang, Albert K. / Zhao, Qihua et al. | 2017
- 3504
-
Direct measurement of clinical mammographic x‐ray spectra using a CdTe spectrometerSantos, Josilene C. / Tomal, Alessandra / Furquim, Tânia A. / Fausto, Agnes M. F. / Nogueira, Maria S. / Costa, Paulo R. et al. | 2017
- 3512
-
The impact of small motion on the visualization of coronary vessels and lesions in cardiac CT: A simulation studyContijoch, Francisco / Stayman, J. Webster / McVeigh, Elliot R. et al. | 2017
- 3525
-
Pixel‐wise estimation of noise statistics on iterative CT reconstruction from a single scanWang, Tonghe / Zhu, Lei et al. | 2017
- 3534
-
Validation of phantom‐based harmonization for patient harmonizationPanetta, Joseph V. / Daube‐Witherspoon, Margaret E. / Karp, Joel S. et al. | 2017
- 3545
-
Referenceless magnetic resonance temperature imaging using Gaussian process modelingYung, Joshua P. / Fuentes, David / MacLellan, Christopher J / Maier, Florian / Liapis, Yannis / Hazle, John D. / Stafford, R. Jason et al. | 2017
- 3556
-
An integrated segmentation and shape‐based classification scheme for distinguishing adenocarcinomas from granulomas on lung CTAlilou, Mehdi / Beig, Niha / Orooji, Mahdi / Rajiah, Prabhakar / Velcheti, Vamsidhar / Rakshit, Sagar / Reddy, Niyoti / Yang, Michael / Jacono, Frank / Gilkeson, Robert C. et al. | 2017
- 3570
-
Mitigating differential baseline shifts in locally advanced lung cancer patients using an average anatomy modelAbdoli, Mehrsima / Van Kranen, Simon R. / Stankovic, Uros / Rossi, Maddalena M. G. / Belderbos, Jose S. A. / Sonke, Jan‐Jakob et al. | 2017
- 3579
-
Breast‐density measurement using photon‐counting spectral mammographyJohansson, Henrik / von Tiedemann, Miriam / Erhard, Klaus / Heese, Harald / Ding, Huanjun / Molloi, Sabee / Fredenberg, Erik et al. | 2017
- 3594
-
Computed tomography quantification of tracheal abnormalities in COPD and their influence on airflow limitationGallardo Estrella, Leticia / Pompe, Esther / Kuhnigk, Jan‐Martin / Lynch, David A. / Bhatt, Surya P. / van Ginneken, Bram / van Rikxoort, Eva Marjolein et al. | 2017
- 3604
-
Differentiation of fat‐poor angiomyolipoma from clear cell renal cell carcinoma in contrast‐enhanced MDCT images using quantitative feature classificationLee, Han Sang / Hong, Helen / Jung, Dae Chul / Park, Seunghyun / Kim, Junmo et al. | 2017
- 3615
-
Fully automatic detection of lung nodules in CT images using a hybrid feature setShaukat, Furqan / Raja, Gulistan / Gooya, Ali / Frangi, Alejandro F. et al. | 2017
- 3630
-
Towards ultrasound‐guided adaptive radiotherapy for cervical cancer: Evaluation of Elekta's semiautomated uterine segmentation method on 3D ultrasound imagesMason, Sarah A. / O’Shea, Tuathan P. / White, Ingrid M. / Lalondrelle, Susan / Downey, Kate / Baker, Mariwan / Behrens, Claus F. / Bamber, Jeffrey C. / Harris, Emma J. et al. | 2017
- 3639
-
Design of a short nonuniform acquisition protocol for quantitative analysis in dynamic cardiac SPECT imaging — a retrospective 123I‐MIBG animal studyZan, Yunlong / Long, Yong / Chen, Kewei / Li, Biao / Huang, Qiu / Gullberg, Grant T. et al. | 2017
- 3650
-
Mean‐intercept anisotropy analysis of porous media. I. Analytic formulae for anisotropic Boolean modelsKlatt, Michael A. / Schröder‐Turk, Gerd E. / Mecke, Klaus et al. | 2017
- 3663
-
Mean‐intercept anisotropy analysis of porous media. II. Conceptual shortcomings of the MIL tensor definition and Minkowski tensors as an alternativeKlatt, Michael A. / Schröder‐Turk, Gerd E. / Mecke, Klaus et al. | 2017
- 3676
-
Reproducibility of quantitative high‐throughput BI‐RADS features extracted from ultrasound images of breast cancerHu, Yuzhou / Qiao, Mengyun / Guo, Yi / Wang, Yuanyuan / Yu, Jinhua / Li, Jiawei / Chang, Cai et al. | 2017
- 3686
-
Incorporation of pre‐therapy 18F‐FDG uptake data with CT texture features into a radiomics model for radiation pneumonitis diagnosisAnthony, Gregory J. / Cunliffe, Alexandra / Castillo, Richard / Pham, Ngoc / Guerrero, Thomas / Armato, Samuel G. III / Al‐Hallaq, Hania A. et al. | 2017
- 3695
-
Focal liver lesions segmentation and classification in nonenhanced T2‐weighted MRIGatos, Ilias / Tsantis, Stavros / Karamesini, Maria / Spiliopoulos, Stavros / Karnabatidis, Dimitris / Hazle, John D. / Kagadis, George C. et al. | 2017
- 3706
-
Multiatlas approach with local registration goodness weighting for MRI‐based electron density mapping of head and neck anatomyFarjam, Reza / Tyagi, Neelam / Veeraraghavan, Harini / Apte, Aditya / Zakian, Kristen / Hunt, Margie A. / Deasy, Joseph O. et al. | 2017
- 3718
-
Semiautomated registration of pre‐ and intraoperative CT for image‐guided percutaneous liver tumor ablation interventionsGunay, Gokhan / Luu, Manh Ha / Moelker, Adriaan / van Walsum, Theo / Klein, Stefan et al. | 2017
- 3726
-
Quantitative comparison of clustered microcalcifications in for‐presentation and for‐processing mammograms in full‐field digital mammographyWang, Juan / Nishikawa, Robert M. / Yang, Yongyi et al. | 2017
- 3739
-
Mixed model phase evolution for correction of magnetic field inhomogeneity effects in 3D quantitative gradient echo‐based MRIFatnassi, Chemseddine / Boucenna, Rachid / Zaidi, Habib et al. | 2017
- 3752
-
An adaptive Fuzzy C‐means method utilizing neighboring information for breast tumor segmentation in ultrasound imagesFeng, Yuan / Dong, Fenglin / Xia, Xiaolong / Hu, Chun‐Hong / Fan, Qianmin / Hu, Yanle / Gao, Mingyuan / Mutic, Sasa et al. | 2017
- 3761
-
Technical Note: Transconvolution based equalization of positron energy effects for the use of 68Ge/68Ga phantoms in determining 18F PET recoveryPrenosil, George A. / Hentschel, Michael / Fürstner, Markus / Krause, Thomas / Weitzel, Thilo / Klaeser, Bernd et al. | 2017
- 3767
-
Three‐dimensional finite‐element based deformable image registration for evaluation of pleural cavity irradiation during photodynamic therapyPenjweini, Rozhin / Kim, Michele M. / Zhu, Timothy C. et al. | 2017
- 3776
-
Design of a modulated orthovoltage stereotactic radiosurgery systemFagerstrom, Jessica M. / Bender, Edward T. / Lawless, Michael J. / Culberson, Wesley S. et al. | 2017
- 3788
-
Technical Note: Comparison of peripheral patient dose from MR‐guided 60Co therapy and 6 MV linear accelerator IGRTHauri, Pascal / Hälg, Roger A. / Schneider, Uwe et al. | 2017
- 3794
-
Quantitative ionization chamber alignment to a water surface: Theory and simulationSiebers, Jeffrey V. / Ververs, James D. / Tessier, Frédéric et al. | 2017
- 3805
-
A descriptive and broadly applicable model of therapeutic and stray absorbed dose from 6 to 25 MV photon beamsSchneider, Christopher W. / Newhauser, Wayne D. / Wilson, Lydia J. / Schneider, Uwe / Kaderka, Robert / Miljanić, Saveta / Knežević, Željka / Stolarcyzk, Liliana / Durante, Marco / Harrison, Roger M. et al. | 2017
- 3815
-
Small field dose measurements using plastic scintillation detector in heterogeneous mediaXue, Jinyu / McKay, Jesse D. / Grimm, Jimm / Cheng, Chee‐Wai / Berg, Ronald / Grimm, Shu‐Ya Lisa / Xu, Qianyi / Subedi, Gopal / Das, Indra J. et al. | 2017
- 3821
-
A new approach for radiosynoviorthesis: A dose‐optimized planning method based on Monte Carlo simulation and synovial measurement using 3D slicer and MRITorres Berdeguez, Mirta Bárbara / Thomas, Sylvia / Rafful, Patricia / Arruda Sanchez, Tiago / Medeiros Oliveira Ramos, Susie / Souza Albernaz, Marta / Vasconcellos de Sá, Lidia / Lopes de Souza, Sergio Augusto / Mas Milian, Felix / Silva, Ademir Xavier da et al. | 2017
- 3830
-
Monte Carlo study of the chamber‐phantom air gap effect in a magnetic fieldO'Brien, Daniel J. / Sawakuchi, Gabriel O. et al. | 2017
- 3839
-
Quantitative ionization chamber alignment to a water surface: Performance of multiple chambersVervers, James D. / McEwen, Malcolm R. / Siebers, Jeffrey V. et al. | 2017
- 3848
-
A Monte Carlo model for mean glandular dose evaluation in spot compression mammographySarno, Antonio / Dance, David R. / van Engen, Ruben E. / Young, Kenneth C. / Russo, Paolo / Di Lillo, Francesca / Mettivier, Giovanni / Bliznakova, Kristina / Fei, Baowei / Sechopoulos, Ioannis et al. | 2017
- 3861
-
Technical Note: Direct measurement of continuous TMR data with a 1D tank and automated couch movementsKnutson, Nels C. / Schmidt, Matthew C. / Belley, Matthew D. / Nguyen, Ngoc B. / Li, H. Harold / Sajo, Erno / Price, Michael J. et al. | 2017
- 3866
-
Second cancer risk assessments after involved‐site radiotherapy for mediastinal Hodgkin lymphomaMazonakis, Michalis / Lyraraki, Efrossyni / Damilakis, John et al. | 2017
- 3875
-
REtroSpective Evaluation of Cerebral Tumors (RESECT): A clinical database of pre‐operative MRI and intra‐operative ultrasound in low‐grade glioma surgeriesXiao, Yiming / Fortin, Maryse / Unsgård, Geirmund / Rivaz, Hassan / Reinertsen, Ingerid et al. | 2017
- 3883
-
Erratum: “Estimating organ doses from tube current modulated CT examinations using a generalized linear model” [Med. Phys. Vol 44 (4), 1500–1513 (2017)]Bostani, Maryam / McMillan, Kyle / Lu, Peiyun / Kim, Grace Hyun J. / Cody, Dianna / Arbique, Gary / Bruce Greenberg, S. / DeMarco, John J. / Cagnon, Chris H. / McNitt‐Gray, Michael F. et al. | 2017
- C1
-
Cover| 2017
- e43
-
Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. 132Brock, Kristy K. / Mutic, Sasa / McNutt, Todd R. / Li, Hua / Kessler, Marc L. et al. | 2017
- i
-
Issue Information| 2017