Moving stereotactic fiducial system to obtain a respiratory signal: proof of principle (Englisch)
Freier Zugriff
- Neue Suche nach: Pinelo, Roberto Caballero
- Neue Suche nach: Alfonso, Rodolfo
- Neue Suche nach: Pérez, Yelina González
- Neue Suche nach: García, Albin Ariel
- Neue Suche nach: Rubio, Arnaldo
- Neue Suche nach: Pinelo, Roberto Caballero
- Neue Suche nach: Alfonso, Rodolfo
- Neue Suche nach: Pérez, Yelina González
- Neue Suche nach: García, Albin Ariel
- Neue Suche nach: Rubio, Arnaldo
In:
Journal of Applied Clinical Medical Physics
;
17
, 1
;
80-91
;
2016
-
ISSN:
- Aufsatz (Zeitschrift) / Elektronische Ressource
-
Titel:Moving stereotactic fiducial system to obtain a respiratory signal: proof of principle
-
Beteiligte:Pinelo, Roberto Caballero ( Autor:in ) / Alfonso, Rodolfo ( Autor:in ) / Pérez, Yelina González ( Autor:in ) / García, Albin Ariel ( Autor:in ) / Rubio, Arnaldo ( Autor:in )
-
Erschienen in:Journal of Applied Clinical Medical Physics ; 17, 1 ; 80-91
-
Verlag:
-
Erscheinungsdatum:01.01.2016
-
Format / Umfang:12 pages
-
ISSN:
-
DOI:
-
Medientyp:Aufsatz (Zeitschrift)
-
Format:Elektronische Ressource
-
Sprache:Englisch
-
Schlagwörter:
-
Datenquelle:
Inhaltsverzeichnis – Band 17, Ausgabe 1
Zeige alle Jahrgänge und Ausgaben
Die Inhaltsverzeichnisse werden automatisch erzeugt und basieren auf den im Index des TIB-Portals verfügbaren Einzelnachweisen der enthaltenen Beiträge. Die Anzeige der Inhaltsverzeichnisse kann daher unvollständig oder lückenhaft sein.
- 1
-
The Business of Scientific Publishing| 2016
- 4
-
Optimal unified combination rule in application of Dempster‐Shafer theory to lung cancer radiotherapy dose response outcome analysisHe, Yanyan / Hussaini, M. Yousuff / Gong, Yutao U. T. / Xiao, Ying et al. | 2016
- 12
-
Evaluation of fluence‐based dose delivery incorporating the spatial variation of dosimetric leaf gap (DLG)Kumaraswamy, Lalith K. / Xu, Zhengzheng / Bailey, Daniel W. / Schmitt, Jonathan D. / Podgorsak, Matthew B. et al. | 2016
- 22
-
A neural network‐based 2D/3D image registration quality evaluator for pediatric patient setup in external beam radiotherapyWu, Jian / Su, Zhong / Li, Zuofeng et al. | 2016
- 34
-
On the sensitivity of TG‐119 and IROC credentialing to TPS commissioning errorsMcVicker, Drew / Yin, Fang‐Fang / Adamson, Justus D. et al. | 2016
- 49
-
A new method and device of aligning patient setup lasers in radiation therapyHwang, Ui‐Jung / Jo, Kwanghyun / Lim, Young Kyung / Kwak, Jung Won / Choi, Sang Hyoun / Jeong, Chiyoung / Kim, Mi Young / Jeong, Jong Hwi / Shin, Dongho / Lee, Se Byeong et al. | 2016
- 62
-
Confidence limits for patient‐specific IMRT dose QA: a multi‐institutional study in KoreaKim, Jung‐in / Chung, Jin‐Beom / Song, Ju‐Young / Kim, Sung Kyu / Choi, Yunseok / Choi, Chang Heon / Choi, Won Hoon / Cho, Byungchul / Kim, Jin Sung / Kim, Sung Jin et al. | 2016
- 70
-
Treatment optimization with concurrent SBRT and intracavitary brachytherapy for locally advanced cervical cancerWan, Bin / Lang, Jinyi / Wang, Pei / Ma, C‐M et al. | 2016
- 80
-
Moving stereotactic fiducial system to obtain a respiratory signal: proof of principlePinelo, Roberto Caballero / Alfonso, Rodolfo / Pérez, Yelina González / García, Albin Ariel / Rubio, Arnaldo et al. | 2016
- 92
-
Comparison of volumetric‐modulated arc therapy and dynamic conformal arc treatment planning for cranial stereotactic radiosurgeryMolinier, Jessica / Kerr, Christine / Simeon, Sebastien / Ailleres, Norbert / Charissoux, Marie / Azria, David / Fenoglietto, Pascal et al. | 2016
- 102
-
Dosimetric effects of positioning shifts using 6D‐frameless stereotactic Brainlab system in hypofractionated intracranial radiotherapyJin, Hosang / Keeling, Vance P. / Ali, Imad / Ahmad, Salahuddin et al. | 2016
- 112
-
Feasibility of portal dosimetry for flattening filter‐free radiotherapyChuter, Robert W. / Rixham, Philip A. / Weston, Steve J. / Cosgrove, Vivian P. et al. | 2016
- 121
-
Clinical implementation of multisequence MRI‐based adaptive intracavitary brachytherapy for cervix cancerZoberi, Jacqueline E. / Garcia‐Ramirez, Jose / Hu, Yanle / Sun, Baozhou / Bertelsman, Carol G. / Dyk, Pawel / Schwarz, Julie K. / Grigsby, Perry W. et al. | 2016
- 132
-
Percentage depth dose calculation accuracy of model based algorithms in high energy photon small fields through heterogeneous media and comparison with plastic scintillator dosimetryAlagar, Ananda Giri Babu / Mani, Ganesh Kadirampatti / Karunakaran, Kaviarasu et al. | 2016
- 143
-
Evaluation of MVCT imaging dose levels during helical IGRT: comparison between ion chamber, TLD, and EBT3 filmsMege, Jean‐Pierre / Wenzhao, Sun / Veres, Attila / Auzac, Guillaume / Diallo, Ibrahima / Lefkopoulos, Dimitri et al. | 2016
- 158
-
Quantification of interplay and gradient effects for lung stereotactic ablative radiotherapy (SABR) treatmentsTyler, Madelaine K. et al. | 2016
- 167
-
On the selection of gantry and collimator angles for isocenter localization using Winston‐Lutz testsDu, Weiliang / Johnson, Jennifer L. / Jiang, Wei / Kudchadker, Rajat J. et al. | 2016
- 179
-
Commissioning an Elekta Versa HD linear acceleratorNarayanasamy, Ganesh / Saenz, Daniel / Cruz, Wilbert / Ha, Chul S. / Papanikolaou, Niko / Stathakis, Sotirios et al. | 2016
- 192
-
Pinnacle3 modeling and end‐to‐end dosimetric testing of a Versa HD linear accelerator with the Agility head and flattening filter‐free modesSaenz, Daniel L. / Narayanasamy, Ganesh / Cruz, Wilbert / Papanikolaou, Nikos / Stathakis, Sotirios et al. | 2016
- 207
-
Quantification of dental prostheses on cone‐beam CT images by the Taguchi methodKuo, Rong‐Fu / Fang, Kwang‐Ming / TY, Wong / Hu, Chia Yu et al. | 2016
- 221
-
Optimum location of external markers using feature selection algorithms for real‐time tumor tracking in external‐beam radiotherapy: a virtual phantom studyNankali, Saber / Torshabi, Ahmad Esmaili / Miandoab, Payam Samadi / Baghizadeh, Amin et al. | 2016
- 234
-
Dosimetric impact of dental metallic crown on intensity‐modulated radiotherapy and volumetric‐modulated arc therapy for head and neck cancerKamomae, Takeshi / Itoh, Yoshiyuki / Okudaira, Kuniyasu / Nakaya, Takayoshi / Tomida, Masashi / Miyake, Yoshikazu / Oguchi, Hiroshi / Shiinoki, Takehiro / Kawamura, Mariko / Yamamoto, Noriyuki et al. | 2016
- 246
-
Learning anatomy changes from patient populations to create artificial CT images for voxel‐level validation of deformable image registrationYu, Z. Henry / Kudchadker, Rajat / Dong, Lei / Zhang, Yongbin / Court, Laurence E. / Mourtada, Firas / Yock, Adam / Tucker, Susan L. / Yang, Jinzhong et al. | 2016
- 259
-
Intensity‐modulated radiation therapy dose verification using fluence and portal imaging deviceSumida, Iori / Yamaguchi, Hajime / Das, Indra J. / Kizaki, Hisao / Aboshi, Keiko / Tsujii, Mari / Yamada, Yuji / Suzuki, Osamu / Seo, Yuji / Isohashi, Fumiaki et al. | 2016
- 272
-
Automatic planning of head and neck treatment plansHazell, Irene / Bzdusek, Karl / Kumar, Prashant / Hansen, Christian R / Bertelsen, Anders / Eriksen, Jesper G. / Johansen, Jørgen / Brink, Carsten et al. | 2016
- 283
-
Commissioning of a motion system to investigate dosimetric consequences due to variability of respiratory waveformsCetnar, Ashley J. / James, Joshua / Wang, Brain et al. | 2016
- 293
-
Radiation intensity () and visibility of anatomical structures in head CT examinationsTipnis, Sameer / Thampy, Rajesh / Rumboldt, Zoran / Spampinato, Maria / Matheus, Gisele / Huda, Walter et al. | 2016
- 301
-
The impact of spectral filtration on image quality in micro‐CT systemRen, Liqiang / Ghani, Muhammad U / Wu, Di / Zheng, Bin / Chen, Yong / Yang, Kai / Wu, Xizeng / Liu, Hong et al. | 2016
- 316
-
Gafchromic XR‐QA2 film as a complementary dosimeter for hand‐monitoring in CTF‐guided biopsiesSarmento, Sandra / Pereira, Joana / Sousa, Maria José / Cunha, Luís / Dias, Anabela G. / Pereira, Miguel F. / Oliveira, Augusto D. / Cardoso, João V. / Santos, Luís M. / Gouvêa, Margarida et al. | 2016
- 328
-
Size‐based protocol optimization using automatic tube current modulation and automatic kV selection in computed tomographyMacDougall, Robert D. / Kleinman, Patricia L. / Callahan, Michael J. et al. | 2016
- 342
-
Approaches to interventional fluoroscopic dose curvesWunderle, Kevin A. / Rakowski, Joseph T. / Dong, Frank F. et al. | 2016
- 353
-
Investigation of optimal display size for viewing T1‐weighted MR images of the brain using a digital contrast‐detail phantomFujita, Hideki / Kuwahata, Nao / Hattori, Hiroyuki / Kinoshita, Hiroshi / Fukuda, Haruyuki et al. | 2016
- 360
-
Gafchromic EBT3 film dosimetry in electron beams — energy dependence and improved film read‐outSipilä, Petri / Ojala, Jarkko / Kaijaluoto, Sampsa / Jokelainen, Ilkka / Kosunen, Antti et al. | 2016
- 374
-
Patient dose measurement in common medical X‐ray examinations in IranRasuli, Behrouz / Mahmoud‐Pashazadeh, Ali / Ghorbani, Mohammad / Juybari, Raheleh Tabari / Naserpour, Mozafar et al. | 2016
- 387
-
SafetyNet: streamlining and automating QA in radiotherapyHadley, Scott W. / Kessler, Marc L. / Litzenberg, Dale W. / Lee, Choonik / Irrer, Jim / Chen, Xiaoping / Acosta, Eduardo / Weyburne, Grant / Keranen, Wayne / Lam, Kwok et al. | 2016
- 396
-
Spatially fractionated radiotherapy (GRID) using helical tomotherapyZhang, Xin / Penagaricano, Jose / Yan, Yulong / Liang, Xiaoying / Morrill, Steven / Griffin, Robert J. / Corry, Peter / Ratanatharathorn, Vaneerat et al. | 2016
- 408
-
Soft tissue and water substitutes for megavoltage photon beams: An EGSnrc‐based evaluationAslam, Ambreen / Kakakhel, Muhammad Basim / Shahid, Shaukat Ali / Younas, Lubna / Zareen, Sobia et al. | 2016
- 416
-
Evaluation of commercial extension plates for the ACR CT accreditation phantomGreene‐Donnelly, Kerry A. / Ogden, Kent M. et al. | 2016
- 421
-
Implementation of an in‐house visual feedback system for motion management during radiation therapyNguyen, Vi Nhan V. / Ellerbusch, David C. / Cetnar, Ashley J. / James, Joshua A. / Wang, Brian et al. | 2016
- 428
-
A specially designed domed‐cones template for needles (seeds) fixation and incline insertion in prostate implant brachytherapyYin, Zhao‐Sheng / Tang, Shi‐Qiang / Shi, Jun‐Wen / Chen, Fen / Li, Zi‐Wei / Wu, Jia‐Ming / Jen, Yee‐Min et al. | 2016
- 440
-
An algorithm for automated ROI definition in water or epoxy‐filled NEMA NU‐2 image quality phantomsPierce, Larry A. II / Byrd, Darrin W. / Elston, Brian F. / Karp, Joel S. / Sunderland, John J. / Kinahan, Paul E. et al. | 2016
- 457
-
AAPM Medical Physics Practice Guideline 5.a.: Commissioning and QA of Treatment Planning Dose Calculations — Megavoltage Photon and Electron Beams| 2016