Reducing the number of samples in spatiotemporal dMRI acquisition design (Englisch)
- Neue Suche nach: Filipiak, Patryk
- Neue Suche nach: Fick, Rutger
- Neue Suche nach: Petiet, Alexandra
- Neue Suche nach: Santin, Mathieu
- Neue Suche nach: Philippe, Anne‐Charlotte
- Neue Suche nach: Lehericy, Stephane
- Neue Suche nach: Ciuciu, Philippe
- Neue Suche nach: Deriche, Rachid
- Neue Suche nach: Wassermann, Demian
- Neue Suche nach: Filipiak, Patryk
- Neue Suche nach: Fick, Rutger
- Neue Suche nach: Petiet, Alexandra
- Neue Suche nach: Santin, Mathieu
- Neue Suche nach: Philippe, Anne‐Charlotte
- Neue Suche nach: Lehericy, Stephane
- Neue Suche nach: Ciuciu, Philippe
- Neue Suche nach: Deriche, Rachid
- Neue Suche nach: Wassermann, Demian
In:
Magnetic Resonance in Medicine
;
81
, 5
;
3218-3233
;
2019
- Aufsatz (Zeitschrift) / Elektronische Ressource
-
Titel:Reducing the number of samples in spatiotemporal dMRI acquisition design
-
Beteiligte:Filipiak, Patryk ( Autor:in ) / Fick, Rutger ( Autor:in ) / Petiet, Alexandra ( Autor:in ) / Santin, Mathieu ( Autor:in ) / Philippe, Anne‐Charlotte ( Autor:in ) / Lehericy, Stephane ( Autor:in ) / Ciuciu, Philippe ( Autor:in ) / Deriche, Rachid ( Autor:in ) / Wassermann, Demian ( Autor:in )
-
Erschienen in:Magnetic Resonance in Medicine ; 81, 5 ; 3218-3233
-
Verlag:
-
Erscheinungsdatum:01.05.2019
-
Format / Umfang:16 pages
-
ISSN:
-
DOI:
-
Medientyp:Aufsatz (Zeitschrift)
-
Format:Elektronische Ressource
-
Sprache:Englisch
-
Schlagwörter:
-
Datenquelle:
Inhaltsverzeichnis – Band 81, Ausgabe 5
Zeige alle Jahrgänge und Ausgaben
Die Inhaltsverzeichnisse werden automatisch erzeugt und basieren auf den im Index des TIB-Portals verfügbaren Einzelnachweisen der enthaltenen Beiträge. Die Anzeige der Inhaltsverzeichnisse kann daher unvollständig oder lückenhaft sein.
- 2823
-
Issue Information| 2019
- 2835
-
A new electron paramagnetic resonance device to measure transcutaneous oxygen in humansHenni, Samir / Hersant, Jeanne / Gourdier, Anne Sophie / Ammi, Myriam / Abraham, Pierre et al. | 2019
- 2837
-
Application of SPOT chip for transcutaneous oximetryKmiec, Maciej M. / Hou, Huagang / Kuppusamy, M. Lakshmi / Drews, Thomas M. / Prabhat, Anjali M. / Petryakov, Sergey V. / Demidenko, Eugene / Schaner, Philip E. / Buckey, Jay C. / Blank, Aharon et al. | 2019
- 2841
-
Fast high‐resolution brain metabolite mapping on a clinical 3T MRI by accelerated H‐FID‐MRSI and low‐rank constrained reconstructionKlauser, Antoine / Courvoisier, Sebastien / Kasten, Jeffrey / Kocher, Michel / Guerquin‐Kern, Matthieu / Van De Ville, Dimitri / Lazeyras, Francois et al. | 2019
- 2858
-
Multicomponent analysis of T1 relaxation in bovine articular cartilage at low magnetic fieldsPetrov, Oleg V. / Stapf, Siegfried et al. | 2019
- 2869
-
Dynamic metabolic imaging of copolarized [2‐13C]pyruvate and [1,4‐13C2]fumarate using 3D‐spiral CSI with alternate spectral band excitationSingh, Maninder / Josan, Sonal / Zhu, Minjie / Jhajharia, Aditya / Mayer, Dirk et al. | 2019
- 2878
-
Robust retrospective frequency and phase correction for single‐voxel MR spectroscopyWilson, Martin et al. | 2019
- 2887
-
Simple and broadly applicable automatic quality control for 3D 1H MR spectroscopic imaging data of the prostateTayari, Nassim / Obels, Jiri / Kobus, Thiele / Scheenen, Tom W.J. / Heerschap, Arend et al. | 2019
- 2896
-
Simian immunodeficiency virus transiently increases brain temperature in rhesus monkeys: detection with magnetic resonance spectroscopy thermometryMintzopoulos, Dionyssios / Ratai, Eva‐Maria / He, Julian / Gonzalez, Ramon Gilberto / Kaufman, Marc J. et al. | 2019
- 2905
-
Improved stimulated echo in diffusion magnetic resonance imaging: introducing a π pulse for SNR enhancementCao, Yupeng / Zhang, Yan / Wang, Yuqing / Liu, Wentao / Han, Dong et al. | 2019
- 2915
-
Improved chemical exchange saturation transfer imaging with real‐time frequency drift correctionLiu, Ruibin / Zhang, Hongxi / Niu, Weiming / Lai, Can / Ding, Qiuping / Chen, Weibo / Liang, Sayuan / Zhou, Jinyuan / Wu, Dan / Zhang, Yi et al. | 2019
- 2924
-
Cerebrospinal fluid–suppressed T2‐weighted MR imaging at 7 T for human brainPan, Jullie W. / Moon, Chan Hong / Hetherington, Hoby P. et al. | 2019
- 2937
-
Phase‐contrast single‐point imaging with synchronized encoding: a more reliable technique for in vitro flow quantificationBruschewski, Martin / Kolkmannn, Hanna / John, Kristine / Grundmann, Sven et al. | 2019
- 2947
-
Cardiorespiratory motion‐tracking via self‐refocused rosette navigatorsRigie, David / Vahle, Thomas / Zhao, Tiejun / Czekella, Björn / Frohwein, Lynn J. / Schäfers, Klaus / Boada, Fernando E. et al. | 2019
- 2959
-
Comparison of in vivo lung morphometry models from 3D multiple b‐value 3He and 129Xe diffusion‐weighted MRIChan, Ho‐Fung / Collier, Guilhem J. / Weatherley, Nicholas D. / Wild, Jim M. et al. | 2019
- 2972
-
Robust kidney perfusion mapping in pediatric chronic kidney disease using single‐shot 3D‐GRASE ASL with optimized retrospective motion correctionNery, Fabio / De Vita, Enrico / Clark, Chris A. / Gordon, Isky / Thomas, David L. et al. | 2019
- 2985
-
Measuring intra‐axonal T2 in white matter with direction‐averaged diffusion MRIMcKinnon, Emilie T. / Jensen, Jens H. et al. | 2019
- 2995
-
Acceleration of vessel‐selective dynamic MR Angiography by pseudocontinuous arterial spin labeling in combination with Acquisition of ConTRol and labEled images in the Same Shot (ACTRESS)Suzuki, Yuriko / Okell, Thomas W. / Fujima, Noriyuki / van Osch, Matthias J.P. et al. | 2019
- 3007
-
Rapid dual‐RF, dual‐echo, 3D ultrashort echo time craniofacial imaging: A feasibility studyLee, Hyunyeol / Zhao, Xia / Song, Hee Kwon / Zhang, Rosaline / Bartlett, Scott P. / Wehrli, Felix W. et al. | 2019
- 3017
-
Frequency difference mapping applied to the corpus callosum at 7TTendler, Benjamin C. / Bowtell, Richard et al. | 2019
- 3032
-
Magnetic resonance fingerprinting with dictionary‐based fat and water separation (DBFW MRF): A multi‐component approachCencini, Matteo / Biagi, Laura / Kaggie, Joshua D. / Schulte, Rolf F. / Tosetti, Michela / Buonincontri, Guido et al. | 2019
- 3046
-
Data consistency‐driven determination of ‐fluctuations in gradient‐echo MRIMeineke, Jakob / Nielsen, Tim et al. | 2019
- 3056
-
Measurement of synovial tissue volume in knee osteoarthritis using a semiautomated MRI‐based quantitative approachPerry, Thomas A. / Gait, Andrew / O’Neill, Terence W. / Parkes, Matthew J. / Hodgson, Richard / Callaghan, Michael J. / Arden, Nigel K. / Felson, David T. / Cootes, Timothy F. et al. | 2019
- 3065
-
Mapping water exchange across the blood–brain barrier using 3D diffusion‐prepared arterial spin labeled perfusion MRIShao, Xingfeng / Ma, Samantha J. / Casey, Marlene / D’Orazio, Lina / Ringman, John M. / Wang, Danny J.J. et al. | 2019
- 3080
-
Enhanced hyperpolarized chemical shift imaging based on a priori segmented informationFarkash, Gil / Markovic, Stefan / Novakovic, Mihajlo / Frydman, Lucio et al. | 2019
- 3094
-
Association of bone mineral density and fat fraction with magnetic susceptibility in inflamed trabecular boneBray, Timothy J.P. / Karsa, Anita / Bainbridge, Alan / Sakai, Naomi / Punwani, Shonit / Hall‐Craggs, Margaret A. / Shmueli, Karin et al. | 2019
- 3108
-
Parameter map error due to normal noise and aliasing artifacts in MR fingerprintingKara, Danielle / Fan, Mingdong / Hamilton, Jesse / Griswold, Mark / Seiberlich, Nicole / Brown, Robert et al. | 2019
- 3124
-
Measurement and correction of the bulk magnetic susceptibility effects of fat: application in venous oxygen saturation imagingYang, Esther / Kirkham, Amy A. / Grenier, Justin / Thompson, Richard B. et al. | 2019
- 3138
-
Simultaneous proton resonance frequency shift thermometry and T1 measurements using a single reference variable flip angle T1 methodSvedin, Bryant T. / Payne, Allison / Parker, Dennis L. et al. | 2019
- 3153
-
Efficient shear wave elastography using transient acoustic radiation force excitations and MR displacement encodingHofstetter, Lorne W. / Odéen, Henrik / Bolster, Bradley D. Jr / Mueller, Alexander / Christensen, Douglas A. / Payne, Allison / Parker, Dennis L. et al. | 2019
- 3168
-
Use of dielectric padding to eliminate low convective field artifact in cr‐MREPT conductivity imagesYildiz, Gulsah / Ider, Yusuf Ziya et al. | 2019
- 3185
-
Robust visualization of middle cerebral artery main trunk by enhanced acceleration‐selective arterial spin labeling (eAccASL) for intracranial MRAAkamine, Yuta / Obara, Makoto / Togao, Osamu / Shibukawa, Shuhei / Yoneyama, Masami / Okuaki, Tomoyuki / Van Cauteren, Marc et al. | 2019
- 3192
-
Non‐contrast myocardial infarct scar assessment using a hybrid native T1 and magnetization transfer imaging sequence at 1.5TDuan, Chong / Zhu, Yanjie / Jang, Jihye / Rodriguez, Jennifer / Neisius, Ulf / Fahmy, Ahmed S. / Nezafat, Reza et al. | 2019
- 3202
-
Robust nonadiabatic T2 preparation using universal parallel‐transmit kT‐point pulses for 3D FLAIR imaging at 7 TGras, Vincent / Pracht, Eberhard D. / Mauconduit, Franck / Le Bihan, Denis / Stöcker, Tony / Boulant, Nicolas et al. | 2019
- 3209
-
Stabilization of T2 relaxation and magnetization transfer in cartilage explants by immersion in perfluorocarbon liquidFishbein, Kenneth W. / Sexton, Kyle W. / Celik, Hasan / Reiter, David A. / Bouhrara, Mustapha / Spencer, Richard G. et al. | 2019
- 3218
-
Reducing the number of samples in spatiotemporal dMRI acquisition designFilipiak, Patryk / Fick, Rutger / Petiet, Alexandra / Santin, Mathieu / Philippe, Anne‐Charlotte / Lehericy, Stephane / Ciuciu, Philippe / Deriche, Rachid / Wassermann, Demian et al. | 2019
- 3234
-
3D self‐gated cardiac cine imaging at 3 Tesla using stack‐of‐stars bSSFP with tiny golden angles and compressed sensingZhang, Xiaoyong / Xie, Guoxi / Lu, Na / Zhu, Yanchun / Wei, Zijun / Su, Shi / Shi, Caiyun / Yan, Fei / Liu, Xin / Qiu, Bensheng et al. | 2019
- 3245
-
Microscopic anisotropy misestimation in spherical‐mean single diffusion encoding MRIHenriques, Rafael Neto / Jespersen, Sune N. / Shemesh, Noam et al. | 2019
- 3262
-
Integrated multi‐echo denoising strategy improves identification of inherent language lateralityAmemiya, Shiori / Yamashita, Hiroshi / Takao, Hidemasa / Abe, Osamu et al. | 2019
- 3272
-
Mapping hepatic blood oxygenation by quantitative BOLD (qBOLD) MRIWengler, Kenneth / Wang, Jinhong / Serrano Sosa, Mario / Gumus, Serter / He, Andrea / Hussain, Shahid / Huang, Chuan / Tae Bae, Kyong / He, Xiang et al. | 2019
- 3283
-
Automated selection of myocardial inversion time with a convolutional neural network: Spatial temporal ensemble myocardium inversion network (STEMI‐NET)Bahrami, Naeim / Retson, Tara / Blansit, Kevin / Wang, Kang / Hsiao, Albert et al. | 2019
- 3292
-
A new analysis approach for T2 relaxometry myelin water quantification: Orthogonal Matching PursuitDrenthen, Gerhard S. / Backes, Walter H. / Aldenkamp, Albert P. / Op ’t Veld, Giel J. / Jansen, Jacobus F. A. et al. | 2019
- 3304
-
Predicting chemo‐brain in breast cancer survivors using multiple MRI features and machine‐learningChen, Vincent Chin‐Hung / Lin, Tung‐Yeh / Yeh, Dah‐Cherng / Chai, Jyh‐Wen / Weng, Jun‐Cheng et al. | 2019
- 3314
-
Motion‐robust diffusion compartment imaging using simultaneous multi‐slice acquisitionMarami, Bahram / Scherrer, Benoit / Khan, Shadab / Afacan, Onur / Prabhu, Sanjay P. / Sahin, Mustafa / Warfield, Simon K. / Gholipour, Ali et al. | 2019
- 3330
-
SUSAN: segment unannotated image structure using adversarial networkLiu, Fang et al. | 2019
- 3346
-
Incorporation of a spectral model in a convolutional neural network for accelerated spectral fittingGurbani, Saumya S. / Sheriff, Sulaiman / Maudsley, Andrew A. / Shim, Hyunsuk / Cooper, Lee A.D. et al. | 2019
- 3358
-
Improved repeatability of dynamic contrast‐enhanced MRI using the complex MRI signal to derive arterial input functions: a test‐retest study in prostate cancer patientsKlawer, Edzo M.E. / van Houdt, Petra J. / Simonis, Frank F.J. / van den Berg, Cornelis A.T. / Pos, Floris J. / Heijmink, Stijn W.T.P.J. / Isebaert, Sofie / Haustermans, Karin / van der Heide, Uulke A. et al. | 2019
- 3370
-
High‐permittivity pad design tool for 7T neuroimaging and 3T body imagingvan Gemert, Jeroen / Brink, Wyger / Webb, Andrew / Remis, Rob et al. | 2019
- 3379
-
A novel bioreactor for combined magnetic resonance spectroscopy and optical imaging of metabolism in 3D cell culturesCox, Benjamin L. / Erickson‐Bhatt, Sarah / Szulczewski, Joseph M. / Squirrell, Jayne M. / Ludwig, Kai D. / Macdonald, Erin B. / Swader, Robert / Ponik, Suzanne M. / Eliceiri, Kevin W. / Fain, Sean B. et al. | 2019
- 3392
-
Double‐row 18‐loop transceive–32‐loop receive tight‐fit array provides for whole‐brain coverage, high transmit performance, and SNR improvement near the brain center at 9.4TAvdievich, Nikolai I. / Giapitzakis, Ioannis‐Angelos / Bause, Jonas / Shajan, Gunamony / Scheffler, Klaus / Henning, Anke et al. | 2019
- 3406
-
Size‐adaptable “Trellis” structure for tailored MRI coil arraysZhang, Bei / Brown, Ryan / Cloos, Martijn / Lattanzi, Riccardo / Sodickson, Daniel / Wiggins, Graham et al. | 2019