Perspectives of a Scintillation Detector with High Spatial Resolution for Quantitative Autoradiography in Biological Tissues (Unknown)
- New search for: Franck, D.
- New search for: Aubineau, I.
- New search for: Charon, Y.
- New search for: Henge-Napoli, M. H.
- New search for: Franck, D.
- New search for: Aubineau, I.
- New search for: Charon, Y.
- New search for: Henge-Napoli, M. H.
- New search for: Waker, A. J.
- New search for: Pihet, P.
- New search for: Menzel, H. G.
In:
Advances in Radiation Measurements: Applications and Research Needs in Health Physics and Dosimetry
1/3
;
219
;
1995
-
ISSN:
- Article (Journal) / Print
-
Title:Perspectives of a Scintillation Detector with High Spatial Resolution for Quantitative Autoradiography in Biological Tissues
-
Contributors:Franck, D. ( author ) / Aubineau, I. ( author ) / Charon, Y. ( author ) / Henge-Napoli, M. H. ( author ) / Waker, A. J. / Pihet, P. / Menzel, H. G.
-
Published in:Advances in Radiation Measurements: Applications and Research Needs in Health Physics and Dosimetry , 1/3 ; 219RADIATION PROTECTION DOSIMETRY ; 61, 1/3 ; 219
-
Publisher:
- New search for: NUCLEAR TECHNOLOGY PUBLISHING
-
Publication date:1995-01-01
-
Size:219 pages
-
ISSN:
-
Type of media:Article (Journal)
-
Type of material:Print
-
Language:Unknown
- New search for: 363.1799
- Further information on Dewey Decimal Classification
-
Classification:
DDC: 363.1799 -
Source:
© Metadata Copyright the British Library Board and other contributors. All rights reserved.
Table of contents – Volume 61, Issue 1/3
The tables of contents are generated automatically and are based on the data records of the individual contributions available in the index of the TIB portal. The display of the Tables of Contents may therefore be incomplete.
- 1
-
The Increasing Need for Active Dosemeters in the Nuclear IndustryHirning, C.R. et al. | 1995
- 9
-
The Application of Commercial Semiconductor Chips for Personal Neutron DosimetrySchröder, O. et al. | 1995
- 13
-
New Trends in Scintillation Detection for Dose and Radiation Quality Monitoring PurposesEttinger, K.V. et al. | 1995
- 19
-
Unbiased Metal Oxide Semiconductor Ionising Radiation DosemeterKumurdjian, N. et al. | 1995
- 25
-
Endo-Microdosemeters for the Control of Radiation Effectiveness in Therapy ApplicationsCrossman, J.S.P. et al. | 1995
- 29
-
Potentials of Advanced Gas Detectors for Health PhysicsSauli, F. et al. | 1995
- 39
-
High Resolution Silicon Detectors for Photons and ParticlesStrüder, L. et al. | 1995
- 47
-
Determination of Dose Rates in Beta Radiation Fields Using Extrapolation Chamber and GM CounterBorg, J. et al. | 1995
- 53
-
A Beta Ray Spectrometer Based on a Two-, or Three-Element Silicon Detector Coincidence TelescopeHorowitz, Y.S. et al. | 1995
- 57
-
Progress on Calibration Procedures with Realistic Neutron SpectraChartier, J.L. et al. | 1995
- 63
-
On the Achievement of Operational Radiation Protection Quantities for Mixed Photon-Neutron Radiation FieldsSchuhmacher, H. et al. | 1995
- 67
-
An Analytical Correction for the TEPC Dose Equivalent Response ProblemTaylor, G.C. et al. | 1995
- 71
-
Investigation of Environmental Dosemeters in the Ultra Low Background Facility 'UDO'Lauterbach, U. et al. | 1995
- 73
-
Properties of An Air-Flow Ionisation Chamber for the Measurement of Beta ContaminationWaker, A.J. et al. | 1995
- 77
-
Airborne Alpha Emitters Monitored by a Glass Fibre Scintillator BundleKim, I.S. et al. | 1995
- 81
-
Characterisation of Photon-Neutron Radiation Fields for Radiation Protection Monitoring and OptimisationSchuhmacher, H. et al. | 1995
- 89
-
Determination of Neutron and Photon Dose Equivalent at Workplaces in Nuclear Facilities in SwedenLindborg, L. et al. | 1995
- 101
-
Physical Interaction of Ionising Radiations with the Intracellular Macromolecular Target DNA and its Biological ConsequencesGeard, C.R. et al. | 1995
- 107
-
Quantitative Description of Particle Interactions with Biological SamplesBraby, L.A. et al. | 1995
- 113
-
Effects of High Intensity and Pulsed Radiation on the Response of the HANDI-TEPCAroua, A. et al. | 1995
- 119
-
TEPC Measurements with the Variance-Covariance Method on Board AircraftLindborg, L. et al. | 1995
- 125
-
Microdosimetry Using a Recombination Chamber: Method and ApplicationsGolnik, N. et al. | 1995
- 129
-
Low Level Neutron Monitoring Using High Pressure 3He DetectorsPszona, S. et al. | 1995
- 133
-
Estimation of Neutron Energy Spectra with Bubble Detectors: Potential and LimitationsRosenstock, W. et al. | 1995
- 137
-
Rapid Monitoring of Gaseous Radionuclides Using a Portable SpectrometerChung, C. et al. | 1995
- 141
-
Deterministic Analytical Method for the Calibration of Semiconductor Detectors in Gamma Ray SpectrometryGenicot, J.L. et al. | 1995
- 145
-
Effect of Radionuclide Distributions on Lung Counting EfficiencyKramer, G.H. et al. | 1995
- 149
-
Perspectives of Silicon Detectors for X and Low Energy Gamma Ray Spectroscopy in Whole-Body CountingPihet, P. et al. | 1995
- 153
-
Study of an Integrated Electronic monitor for Neutron FieldsBarelaud, B. et al. | 1995
- 159
-
Active Neutron Spectrometry with Superheated Drop (Bubble) Detectorsd'Errico, F. et al. | 1995
- 163
-
Design of a New High Energy Neutron Dose Equivalent Meter by Monte Carlo SimulationsHsu, H.-H. et al. | 1995
- 167
-
Monte Carlo Calculation of High Energy Neutron Responses for Improved Andersson-Braun Rem MetersHsu, H.-H. et al. | 1995
- 171
-
Numerical Simulation of a Low Pressure Proportional Counter Used for Area MonitoringFreyermuth, M. et al. | 1995
- 175
-
Improving a Multicellular Tissue-Equivalent Proportional Counter for Personal Neutron DosimetryBordy, J.M. et al. | 1995
- 179
-
Counting Protons with Semiconductors -- A Simple Approach to a Personal Neutron DosemeterSchröder, O. et al. | 1995
- 183
-
An Assessment of the Feasibility of Using Monte Carlo Calculations to Model a Combined Neutron-Gamma Electronic Personal DosemeterTanner, J.E. et al. | 1995
- 187
-
Commercial Technology in the Development of Portable Active Detection InstrumentsConroy, T.L. et al. | 1995
- 193
-
Variance-Covariance Measurements in Photon Beams for Simulated Nanometer ObjectsGrindborg, J.E. et al. | 1995
- 199
-
A Single-Electron Counter for NanodosimetryBreskin, A. et al. | 1995
- 205
-
Multi-Level Modelling of the Response of the Ultraminiature Proportional Counter: Gas Gain Phenomena and Pulse Height SpectraOlko, P. et al. | 1995
- 211
-
A Feasibility Study of Scintillator Microdosemeters for Measurement of the Biological Effectiveness of Ionising RadiationsWatt, D.E. et al. | 1995
- 215
-
Conventional and Microbeam Studies Using Low Energy Charged Particles Relevant to Risk Assessment and the Mechanisms of Radiation ActionFolkard, M. et al. | 1995
- 219
-
Perspectives of a Scintillation Detector with High Spatial Resolution for Quantitative Autoradiography in Biological TissuesFranck, D. et al. | 1995
- 221
-
A New Method to Study Low Dose Radiation DamageReist, H.W. et al. | 1995
- 225
-
Secondary Ion Mass Spectrometry of Tissues and Thin Foils. Recent Developments and Applications to Radiation ProtectionGalle, P. et al. | 1995
- 231
-
Knowledge of Particle Interaction with Gaseous and Dense Material: The Behaviour of Secondary ElectronsSanche, L. et al. | 1995
- 237
-
Measurement of the Energy Distribution of Low Energy Electrons as a Function of Gas Density: Determination of Absolute Differential Electron-Atom Scattering Cross SectionsBaek, W.Y. et al. | 1995
- 245
-
The Backscattering of Low Energy Protons in Gases of Importance for Ionisation MeasurementsGrosswendt, B. et al. | 1995
- 253
-
Effects of the Electric Field on Ionisation in Two Different Types of Ionisation ChambersTakata, N. et al. | 1995
- 257
-
The Electronic Avalanche in Proportional CountersColautti, P. et al. | 1995
- 263
-
A Study of Argon-Isobutane Mixtures in a Proportional Counter: Gas Amplification, W Value, and Energy ResolutionKrajcar Bronic, I. et al. | 1995
- 267
-
The Energy Dependence of W Values for Protons of Energies up to 10 MeVGrosswendt, B. et al. | 1995
- 275
-
Measurement of Neutron Kerma Factors in C and O: Neutron Energy Range of 20 MeV to 70 MeVSchrewe, U.J. et al. | 1995
- 281
-
Gas-to-Wall Absorbed Dose Conversion Factors from 25 to 250 MeV Neutron EnergyNewhauser, W.D. et al. | 1995
- 285
-
Neutron W Values in Methane-Based Tissue-Equivalent Gas up to 60 MeVTaylor, G.C. et al. | 1995
- 291
-
Author Index| 1995
- 293
-
List of Participants| 1995
-
Contents| 1995
-
Advances in Radiation Measurements: Application and Research Needs in Health Physics and DosimetryWaker, A.J. et al. | 1995