Medical imaging 2009 - physics of medical imaging : 9 - 12 February 2009, Lake Buena Vista, Florida, United States / sponsored by SPIE. Ehsan Samei ..., ed. ; Pt. 3 (English)
- New search for: Samei, Ehsan
2009
-
ISBN:
- Conference Proceedings / Print
-
Title:Medical imaging 2009 - physics of medical imaging : 9 - 12 February 2009, Lake Buena Vista, Florida, United States / sponsored by SPIE. Ehsan Samei ..., ed. ; Pt. 3
-
Contributors:
-
Conference:Conference ; 2009 ; Lake Buena Vista, Fla.
-
Published in:Proceedings of SPIE ; 7258Progress in biomedical optics and imaging ; Vol. 10, No. 34
-
Publisher:
- New search for: SPIE
-
Place of publication:Bellingham, Wash.
-
Publication date:2009
-
Size:Getr. Zählung [ca. 620 S.]
-
ISBN:
-
Type of media:Conference Proceedings
-
Type of material:Print
-
Language:English
- New search for: 44.64 / 44.09 / 44.31 / 54.74
- Further information on Basic classification
-
Keywords:
-
Classification:
-
Source:
Table of contents conference proceedings
The tables of contents are generated automatically and are based on the data records of the individual contributions available in the index of the TIB portal. The display of the Tables of Contents may therefore be incomplete.
- 72580A
-
Simulation and analysis of image quality impact from single-source ultra-wide coverage CT scannerLi, Baojun / Toth, Thomas L. / Hsieh, Jiang / Tang, Xiangyang / Crandall, Peter / Senzig, Robert F. et al. | 2009
- 72580B
-
Four-dimensional cardiac reconstruction from rotational x-ray sequences: first results for 4D coronary angiographyHansis, Eberhard / Schomberg, Hermann / Erhard, Klaus / Dössel, Olaf / Grass, Michael et al. | 2009
- 72580C
-
High temporal resolution cardiac cone-beam CT using a slowly rotating C-arm gantryChen, Guang-Hong / Tang, Jie / Nett, Brian / Leng, Shuai / Zambelli, Joseph / Qi, Zhihua / Bevins, Nick / Reeder, Scott / Rowley, Howard et al. | 2009
- 72580D
-
Flash imaging in dual source CT (DSCT)Bruder, H. / Petersilka, M. / Mehldau, H. / Heidinger, W. / Allmendinger, T. / Schmidt, B, / Raupach, R. / Thierfelder, C, / Stierstorfer, K. / Flohr, T. et al. | 2009
- 72580E
-
Kyphoplasty interventions using a navigation system and C-arm CT data: first clinical resultsHoheisel, Martin / Skalej, Martin / Beuing, Oliver / Bill, Ulrich / Klingenbeck-Regn, Klaus / Petzold, Ralf / Nagel, Markus H. et al. | 2009
- 72580F
-
Cone-beam CT using a C-arm system as front end and a spherical spiral as source trajectorySchomberg, Hermann / van de Haar, Peter / Baaten, Wil et al. | 2009
- 72580G
-
Quantization of liver tissue in dual kVp computed tomography using linear discriminant analysisTkaczyk, J. Eric / Langan, David / Wu, Xiaoye / Xu, Daniel / Benson, Thomas / Pack, Jed D. / Schmitz, Andrea / Hara, Amy / Palicek, William / Licato, Paul et al. | 2009
- 72580H
-
Patient specific computerized phantoms to estimate dose in pediatric CTSegars, W. P. / Sturgeon, G. / Li, X. / Cheng, L. / Ceritoglu, C. / Ratnanather, J. T. / Miller, M. I. / Tsui, B. M. W. / Frush, D. / Samei, E. et al. | 2009
- 72580I
-
Three-dimensional imaging properties of rotation-free square and hexagonal micro-CT systemsQuan, Enzhuo / Lalush, David S. et al. | 2009
- 72580J
-
Enhanced computer simulation of CT mammography using a flat-panel imagerDidier, Clay S. / O'Connor, J. Michael / Chen, Yu / Glick, Stephen J. et al. | 2009
- 72580K
-
Volume and tissue composition preserving deformation of breast CT images to simulate breast compression in mammographic imagingHan, Tao / Chen, Lingyun / Lai, Chao-Jen / Liu, Xinming / Shen, Youtao / Zhong, Yuncheng / Ge, Shuaiping / Yi, Ying / Wang, Tianpeng / Shaw, Chris C. et al. | 2009
- 72580L
-
Breast density measurement: 3D cone beam computed tomography (CBCT) images versus 2D digital mammogramsHan, Tao / Lai, Chao-Jen / Chen, Lingyun / Liu, Xinming / Shen, Youtao / Zhong, Yuncheng / Ge, Shuaiping / Yi, Ying / Wang, Tianpeng / Yang, Wei T. et al. | 2009
- 72580M
-
Visibility of microcalcifications in CCD-based cone beam CT: a preliminary studyShen, Youtao / Chen, Lingyun / Ge, Shuaiping / Yi, Ying / Han, Tao / Zhong, Yuncheng / Lai, Chao-Jen / Liu, Xinming / Wang, Tianpeng / Shaw, Chris C. et al. | 2009
- 72580O
-
Estimating breast tomosynthesis performance in detection tasks with variable-background phantomsYoung, Stefano / Park, Subok / Anderson, S. Kyle / Badano, Aldo / Myers, Kyle J. / Bakic, Predrag et al. | 2009
- 72580P
-
Optimized lesion detection in digital breast tomosynthesisChawla, Amarpreet S. / Samei, Ehsan / Lo, Joseph Y. et al. | 2009
- 72580Q
-
Nonuniform angular dose distribution in digital breast tomosynthesis for increased conspicuity of small high contrast objectsHu, Yue-Houng / Zhao, Wei et al. | 2009
- 72580R
-
The effect of lag on image quality for a digital breast tomosynthesis systemMainprize, James G. / Wang, Xinying / Yaffe, Martin J. et al. | 2009
- 72580S
-
Computerized 3D breast phantom with enhanced high-resolution detailLi, Christina M. / Segars, W. Paul / Lo, Joseph Y. / Veress, Alexander I. / Boone, John M. / Dobbins, James T. et al. | 2009
- 72580T
-
Blind motion compensation for positron-emission-tomographyBlume, Moritz / Keil, Andreas / Navab, Nassir / Rafecas, Magdalena et al. | 2009
- 72580U
-
Joint image reconstruction and nonrigid motion estimation with a simple penalty that encourages local invertibilityChun, Se Young / Fessler, Jeffrey A. et al. | 2009
- 72580V
-
Direct reconstruction of PET receptor binding parametric images using a simplified reference tissue modelWang, Guobao / Qi, Jinyi et al. | 2009
- 72580W
-
Advanced reconstruction of attenuation maps using SPECT emission data onlySalomon, André / Goedicke, Andreas / Aach, Til et al. | 2009
- 72580X
-
HyperSPECT: a new system for pre-clinical imaging in vivoTibbelin, Sandra / Nillius, Peter / Cederström, Björn / Danielsson, Mats et al. | 2009
- 72580Y
-
Novel insight into magnetic resonance through a spherical coordinate framework for the Bloch equationTahayori, Bahman / Johnston, Leigh A. / Mareels, Iven M. Y. / Farrell, Peter M. et al. | 2009
- 72580Z
-
Regularization of parallel MRI reconstruction using in vivo coil sensitivitiesDuan, Qi / Otazo, Ricardo / Xu, Jian / Sodickson, Daniel K. et al. | 2009
- 72581A
-
Extension of DQE to include scatter, grid, magnification, and focal spot blur: a new experimental technique and metricRanger, N. T. / Mackenzie, A. / Honey, I. D. / Dobbins, J. T. / Ravin, C. E. / Samei, E. et al. | 2009
- 72581B
-
Noise analysis of full field digital mammography systemsRavaglia, V. / Bouwman, R. / Young, K. / Van Engen, R. / Lazzari, B. et al. | 2009
- 72581C
-
Predicting contrast detail performance from objective measurements in digital mammographyYoung, Kenneth C. / Alsager, Abdulaziz / Dance, David R. / Oduko, Jennifer M. / Gundogdu, Ozcan / Spyrou, Nicholas M. et al. | 2009
- 72581D
-
SKE/BKE task-based methodology for calculating Hotelling observer SNR in mammographyLiu, Haimo / Kyprianou, Iacovos S. / Badano, Aldo / Myers, Kyle J. / Jennings, Robert J. / Park, Subok / Kaczmarek, Richard V. / Chakrabarti, Kish et al. | 2009
- 72581G
-
Feasibility of amorphous selenium based photon counting detectors for digital breast tomosynthesisChen, Jiong / Lehnert, Joerg / O'Connor, Paul / De Geronimo, Gianluigi / Dolazza, Enrico / Tousignant, Olivier / Laperrière, Luc / Greenspan, Jonathan / Zhao, Wei et al. | 2009
- 72581H
-
Evaluation of the x-ray response of amorphous selenium coated 100-μm pitch a-Si active pixel sensors for tomosynthesis applicationsTaghibakhsh, Farhad / Hunter, David M. / Karim, Karim S. / Belev, George / Kasap, Safa O. / Verpakhovski, Vladimir / Yaffe, Martin J. et al. | 2009
- 72581I
-
Direct-conversion 50 μm pixel-pitch detector for digital mammography using amorphous selenium as a photoconductive switching layer for signal charge readoutIrisawa, K. / Yamane, K. / Imai, S. / Ogawa, M. / Shouji, T. / Agano, T. / Hosoi, Y. / Hayakawa, T. et al. | 2009
- 72581J
-
A photon-counting detector for dual-energy breast tomosynthesisFredenberg, Erik / Lundqvist, Mats / Åslund, Magnus / Hemmendorff, Magnus / Cederström, Björn / Danielsson, Mats et al. | 2009
- 72581K
-
First physical measurements and clinical evaluation for long-view tomosynthesisNotohara, Daisuke / Nishino, Kazuyoshi / Shibata, Koichi et al. | 2009
- 72581L
-
A task-based evaluation method for x-ray breast imaging systems using variable-background phantomsPark, Subok / Liu, Haimo / Jennings, Robert / Leimbach, Robert / Kyprianou, Iacovos / Badano, Aldo / Myers, Kyle et al. | 2009
- 72581M
-
Analysis of lung nodule detectability and anatomical clutter in tomosynthesis imaging of the chestYoon, Sungwon / Gang, Jianan G. / Tward, Daniel J. / Siewerdsen, Jeffrey H. / Fahrig, Rebecca et al. | 2009
- 72581N
-
Multiple information tomosynthesis with grating-based phase-contrast imagingWang, Zhentian / Huang, Zhifeng / Xiao, Yongshun / Zhang, Li / Kang, Kejun et al. | 2009
- 72581O
-
Imaging of small children with a prototype for photon counting tomosynthesisdel Risco Norrlid, Lilián / Fredenberg, Erik / Hemmendorff, Magnus / Jackowski, Christian / Danielsson, Mats et al. | 2009
- 72581P
-
The impact of anisotropic sampling on the MTF reconstruction in limited aperture tomosynthesisSouchay, H. / Klausz, R. et al. | 2009
- 72581Q
-
Geometric calibration and distortion calibration for CT from scans of unknown objects using complementary raysHolt, Kevin M. et al. | 2009
- 72581S
-
Optimal binary coding matrices for multiplexed x-ray imagingLalush, David S. et al. | 2009
- 72581T
-
Quantitative evaluation of noise reduction algorithms for very low dose renal CT perfusion imagingLiu, Xin / Primak, Andrew N. / Yu, Lifeng / Li, Hua / Krier, James D. / Lerman, Lilach O. / McCollough, Cynthia H. et al. | 2009
- 72581U
-
Prior-image-based few-view cone beam CT for applications to daily scan in image-guided radiation therapy: preliminary studyCho, Seungryong / Pearson, Erik / Sidky, Emil Y. / Bian, Junguo / Pelizzari, Charles A. / Pan, Xiaochuan et al. | 2009
- 72581V
-
Image-based online correction of misalignment artifacts in cone-beam CTKyriakou, Y. / Lapp, R. M. / Hillebrand, L. / Ertel, D. / Kalender, W. A. et al. | 2009
- 72581W
-
Image-based iterative compensation of motion artifacts in computed tomographySchretter, Colas / Neukirchen, Christoph / Rose, Georg / Bertram, Matthias et al. | 2009
- 72581X
-
Elimination of blooming artifacts off stents by dual energy CTZou, Yu / Silver, Michael D. et al. | 2009
- 72581Y
-
Spurious structures created by interpolation-based CT metal artifact reductionMüller, J. / Buzug, T. M. et al. | 2009
- 72581Z
-
Efficient scatter correction using asymmetric kernelsStar-Lack, Josh / Sun, Mingshan / Kaestner, Anders / Hassanein, Rene / Virshup, Gary / Berkus, Timo / Oelhafen, Markus et al. | 2009
- 72582A
-
Interactive GPU-accelerated image reconstruction in cone-beam CTHillebrand, Lars / Lapp, Robert M. / Kyriakou, Yiannis / Kalender, Willi A. et al. | 2009
- 72582B
-
GPU-accelerated SART reconstruction using the CUDA programming environmentKeck, Benjamin / Hofmann, Hannes / Scherl, Holger / Kowarschik, Markus / Hornegger, Joachim et al. | 2009
- 72582C
-
Effect of detector time delay and its correction in multiple source computed tomographyThran, A. / Forthmann, P. / Proksa, R. et al. | 2009
- 72582D
-
Noise correlation in CBCT projection data and its application for noise reduction in low-dose CBCTWang, Jing / Chai, Anwei / Xing, Lei et al. | 2009
- 72582E
-
Geometric calibration of detectors with discrete irregularities for computed tomographyHolt, Kevin M. et al. | 2009
- 72582F
-
Simultaneous activity and attenuation reconstruction in PET: applying partially known attenuationFuruie, Sergio S. et al. | 2009
- 72582H
-
Real-time compression of raw computed tomography data: technology, architecture, and benefitsWegener, Albert / Chandra, Naveen / Ling, Yi / Senzig, Robert / Herfkens, Robert et al. | 2009
- 72582I
-
Perfusion from angiogram and a priori (PAP) with temporal regularizationTaguchi, Katsuyuki / Geschwind, Jean-Francois H. et al. | 2009
- 72582J
-
Bronchial wall region extraction algorithm using multi-slice CT imagesAkashi, Kengo / Saita, Shinsuke / Kubo, Mitsuru / Kawata, Yoshiki / Niki, Noboru / Nakano, Yasutaka / Niimi, Akio / Matsumoto, Hisako / Oguma, Tsuyoshi / Takiguchi, Yuichi et al. | 2009
- 72582K
-
Volumetric soft tissue brain imaging on xCAT, a mobile flat-panel x-ray CT systemZbijewski, Wojciech / Stayman, J. Webster et al. | 2009
- 72582L
-
Image reconstruction for a stationary digital breast tomosynthesis systemRajaram, Ramya / Yang, Guang / Quan, Enzhuo / Frederick, Brandon / Lalush, David S. / Zhou, Otto Z. et al. | 2009
- 72582M
-
Local correction of non-periodic motion in computed tomographySchretter, Colas / Neukirchen, Christoph / Rose, Georg / Bertram, Matthias et al. | 2009
- 72582N
-
Toward region of interest computer tomographySchafer, Sebastian / Noël, Peter B. / Walczak, Alan M. / Hoffmann, Kenneth R. et al. | 2009
- 72582O
-
Wavelet based de-noising methods for local SPECT reconstruction with nonuniform attenuationWang, Li / Wen, Junhai / Yang, Jing / Chen, Yunbin / Liang, Zhengrong et al. | 2009
- 72582P
-
A noise decomposition method for image quality analysis of medical radiography detectorsAl Tahli, Sami / Maack, Ingo / Koch, Andreas / Herrmann, Clemens et al. | 2009
- 72582Q
-
Evaluating low pass filters on SPECT reconstructed cardiac orientation estimationDwivedi, Shekhar et al. | 2009
- 72582R
-
Systematic scanner variability of patient CT attenuation measurementsJudy, Philip F. / Nawfel, Richard D. / Silverman, Stuart G. et al. | 2009
- 72582S
-
An experimental cone-beam micro-CT system for small animal imagingZhu, Shouping / Tian, Jie / Yan, Guorui / Qin, Chenghu / Liu, Junting et al. | 2009
- 72582T
-
4D micro-CT-based perfusion imaging in small animalsBadea, C. T. / Johnston, S. M. / Lin, M. / Hedlund, L. W. / Johnson, G. A. et al. | 2009
- 72582U
-
Attenuation and image noise level based online z-axis tube current modulation for CT scans independent with localizer radiograph: simulation study and resultsTian, Yi / Chen, Mahao / Kong, Jun et al. | 2009
- 72582V
-
CBCT/CBDT equipped with the x-ray projection system for image-guided proton therapyCho, Min Kook / Kim, Jin Sung / Cho, Young-Bin / Youn, Hanbean / Park, Sung Yong / Cho, Seungryong / Kim, Ho Kyung et al. | 2009
- 72582W
-
Clinical micro-CT for dental imagingYoun, Hanbean / Cho, Min Kook / Shon, Cheol-Soon / Cho, Bong Hae / Kim, Chang Hyuk / Kim, Ho Kyung et al. | 2009
- 72582Y
-
Preliminary feasibility of dedicated breast CT with an inverse geometryGilat Schmidt, Taly et al. | 2009
- 72582Z
-
Study of signal-to-noise ratio in digital mammographyKato, Yuri / Fujita, Naotoshi / Kodera, Yoshie et al. | 2009
- 72583A
-
High-contrast artifact reduction in cone beam computed tomography by using geometric techniquesNoël, Peter B. / Xu, Jinhui / Hoffmann, Kenneth R. / Corso, Jason J. / Schafer, Sebastian / Walczak, Alan M. et al. | 2009
- 72583B
-
Real time implementation of distortion corrections for a tiled EMCCD-based solid state x-ray image intensifier (SSXII)Keleshis, Christos / Hoffmann, K. R. / Lee, J. / Hamwi, H. / Wang, W. / Ionita, C. N. / Bednarek, D. R. / Verevkin, A. / Rudin, S. et al. | 2009
- 72583C
-
Measurement-based scatter correction for cone-beam CT in radiation therapyZhu, Lei / Xing, Lei et al. | 2009
- 72583D
-
Three-dimensional metal artifact reduction method for dental conebeam CT scannersKobayashi, Koji / Katsumata, Atsushi / Ito, Koichi / Aoki, Takafumi et al. | 2009
- 72583E
-
Reduction of artifacts due to multiple metallic objects in computed tomographyJeong, Kye Young / Ra, Jong Beom et al. | 2009
- 72583F
-
Reduction of aliasing artifacts in tomographic imagesTischenko, Oleg / Xu, Yuan / Goetzfried, Thomas / Bogner, Ludwig / Hoeschen, Christoph et al. | 2009
- 72583G
-
Attenuation compensation in mesh-domain OSEM SPECT reconstructionVogelsang, Levon / Lu, Yao / Yu, Bo / Krol, Andrzej / Xu, Yuesheng / Hu, Xiaofei / Feiglin, David / Lipson, Edward et al. | 2009
- 72583H
-
How many x-ray photons can be scattered from a SPECT/CT room to an adjacent gamma camera?Cao, Zongjian et al. | 2009
- 72583I
-
Feasibility study of CMOS detectors for mammographyHan, Jong Chul / Yun, Seungman / Lim, Chang Hwy / Kim, Tae Woo / Kim, Ho Kyung et al. | 2009
- 72583J
-
Flat detector ghost image reduction by UV irradiationSnoeren, Rudolph M. / Steinhauser, Heidrun / Alving, Lex / Stouten, Hans / de With, Peter H. N. et al. | 2009
- 72583K
-
A counting and integrating pixel readout chip for amorphous selenium direct radiation detectors for medical imaging applicationsGoldan, A. H. / Hadji, Bahman / Karim, K. S. / DeCrescenzo, G. / Rowlands, J. A. / Tousignant, O. / Laperrière, L. et al. | 2009
- 72583L
-
Quasi-monochromatic x-ray filter with thin film multilayer for a large area radiation fieldPark, Youngsei / Han, Sejin / Chae, Jangyeol / Kim, Changkyu / Chon, Kwon S. / Lee, Hyoung-Koo / Han, D. S. et al. | 2009
- 72583M
-
Advanced a-Se film with high sensitivity and heat resistance for x-ray detectorsOgusu, Koichi / Nakane, Osamu / Igasaki, Yasunori / Okamura, Yoshinori / Yamada, Satoshi / Hirai, Tadaaki et al. | 2009
- 72583N
-
Pixel-structured scintillators for digital x-ray imagingYun, Seung Man / Lim, Chang Hwy / Kim, Tae Woo / Kim, Ho Kyung et al. | 2009
- 72583O
-
Optimized operation and offset corrections for a battery-powered wireless digital x-ray detectorTöpfer, Karin / Dehority, John et al. | 2009
- 72583P
-
Betacam: a commercial approach to β-autoradiographyCabello, J. / Holland, A. / Holland, K. / Bailey, A. / Kitchen, I. / Wells, K. et al. | 2009
- 72583Q
-
Characterization of bias induced metastability of amorphous silicon thin film transistor based passive pixel sensor switch and its impact on biomedical x-ray imaging applicationSultana, Afrin / Safavian, N. / Izadi, M. H. / Karim, K. S. / Rowlands, J. A. et al. | 2009
- 72583R
-
Dual energy with dual source CT and kVp switching with single source CT: a comparison of dual energy performanceGrasruck, M. / Kappler, S. / Reinwand, M. / Stierstorfer, K. et al. | 2009
- 72583S
-
Image-based dual energy CT improvements using Gram-Schmidt methodPark, Kyung-Kook / Pavlicek, William / Boltz, Thomas / Paden, Robert / Hara, Amy / Akay, Metin et al. | 2009
- 72583T
-
Dual energy CT via fast kVp switching spectrum estimationXu, Dan / Langan, David A. / Wu, Xiaoye / Pack, Jed D. / Benson, Thomas M. / Tkaczky, J. Eric / Schmitz, Andrea M. et al. | 2009
- 72583U
-
Dual-energy contrast enhanced digital mammography: theoretical and experimental study of optimal monoenergetic beam parameters using synchrotron radiationPuong, Sylvie / Iordache, Razvan / Bouchevreau, Xavier / Muller, Serge et al. | 2009
- 72583V
-
Pre-reconstruction three-material decomposition in dual-energy CTYu, Lifeng / Liu, Xin / McCollough, Cynthia H. et al. | 2009
- 72583W
-
Enhanced discrimination of calcified and soft arterial plaques using computed tomography with a multi-energy-window photon counting x-ray detectorWang, Xiaolan / Xu, Jingyan / Taguchi, Katsuyuki / Patt, Bradley E. / Wagenaar, Douglas J. / Frey, Eric C. et al. | 2009
- 72583X
-
Impact of scattered radiation on spectral CTWiegert, Jens / Engel, Klaus Jürgen / Herrmann, Christoph et al. | 2009
- 72583Y
-
Empirical projection-based basis-component decomposition methodBrendel, Bernhard / Roessl, Ewald / Schlomka, Jens-Peter / Proksa, Roland et al. | 2009
- 72583Z
-
Linearity between CT number and iodine concentration and application to improving accuracy of CT number in slow kV-switching dual energy CTZou, Yu / Silver, Michael D. et al. | 2009
- 72584A
-
A novel method to reduce data acquisition time in differential phase contrast: computed tomography using compressed sensingQi, Zhihua / Zambelli, Joseph / Bevins, Nicholas / Chen, Guang-Hong et al. | 2009
- 72584B
-
Investigation of quantitative polychromatic x-ray phase-contrast tomography for tissue characterizationChou, Cheng-Ying / Zysk, Adam M. / Anastasio, Mark A. et al. | 2009
- 72584C
-
MEG beamforming: magnetic source imagingLei, Tianhu / Roberts, Timothy P. L. et al. | 2009
- 72584D
-
Dose efficiency consideration for volume-of-interest breast imaging using x-ray differential phase-contrast CTCai, Weixing / Ning, Ruola et al. | 2009
- 72584E
-
Analysis of the spectrum in phase-contrast mammographyZysk, Adam M. / Xu, Qiaofeng / de Sisternes, Luis / Brankov, Jovan G. / Wernick, Miles N. / Anastasio, Mark A. et al. | 2009
- 72584G
-
Three-dimensional photoacoustic tomography of finger joint: from phantom experiment to in vivo studySun, Yao / Jiang, Huabei et al. | 2009
- 72584H
-
Marginal adaptation analysis performed with en face optical coherence tomography in fixed partial denturesSinescu, Cosmin / Negrutiu, Meda Lavinia / Antonie, Sergiu / Dobre, George / Bradu, Adrian / Hughes, Michael / Rominu, Mihai / Podoleanu, Adrian Gh. et al. | 2009
- 72584I
-
Resolution improvement of the molecular imaging technique based on magnetic nanoparticlesIshihara, Yasutoshi / Kusayama, Yusuke et al. | 2009
- 72584J
-
Method for optic nerve intensity characterization in mice from Mn2+enhanced MR imagesXiao, D. / Ribic, J. / Butzkueven, H. / Fang, K. / Kilpatrick, T. J. / Egan, G. F. / Salvado, O. et al. | 2009
- 72584K
-
Effect of masticatory load on crack deflection/penetration investigated with en-face optical coherence tomography in ceramic fixed partial denturesSinescu, Cosmin / Negrutiu, Meda Lavinia / Marsavina, Liviu / Negru, Radu / Hluscu, Mihai / Caplescu, Cristiana / Bradu, Adrian / Hughes, Michael / Rominu, Mihai / Podoleanu, Adrian Gh. et al. | 2009
- 72584L
-
Effect of subdicing on the dispersion and resonance behavior of elastic guided waves in 1D array ultrasound transducersCortes, Daniel H. / Datta, Subhendu K. / Mukdadi, Osama M. et al. | 2009
- 72584M
-
Image quality and signal distribution in 1.5-T and 3-T MRI in mild traumatic brain injury patientsRossi, Maija E. / Dastidar, Prasun / Ryymin, Pertti / Ylinen, Aarne / Öhman, Juha / Soimakallio, Seppo / Eskola, Hannu et al. | 2009
- 72584N
-
Optical coherence tomography and confocal microscopy investigations of dental structures and restoration materialsNegrutiu, Meda L. / Sinescu, Cosmin / Rominu, Mihai / Hughes, Michael / Dobre, George / Podoleanu, Adrian G. et al. | 2009
- 72584O
-
A new linear least squares method for T1 estimation from SPGR signals with multiple TRsChang, Lin-Ching / Koay, Cheng Guan / Basser, Peter J. / Pierpaoli, Carlo et al. | 2009
- 72584P
-
Image quality evaluation of direct-conversion digital mammography system with new dual a-Se layer detectorKuwabara, Takao / Iwasaki, Nobuyuki / Sendai, Tomonari / Furue, Ryosuke / Agano, Toshitaka et al. | 2009
- 72584Q
-
The effect of dose reductions on lesion detection in head CTElojeimy, Saeed / Huda, Walter / Ogden, Kent M. / Owen, Ryan / Samei, Ehsan / Rumboldt, Zoran et al. | 2009
- 72584R
-
Modification of the NEMA XR21-2000 cardiac phantom for testing of imaging systems used in endovascular image guided interventionsIonita, C. N. / Dohatcu, A. / Jain, A. / Keleshis, C. / Hoffmann, K. R. / Bednarek, D. R. / Rudin, S. et al. | 2009
- 72584S
-
Image quality evaluation of a LightSpeed CT750 HD computed tomography systemFan, Jiahua / Dong, Frank / Sainath, Paavana / Hsieh, Jiang / Tang, Xiangyang / Toth, Thomas / Li, Baojun / Crandall, Peter / Senzig, Robert / Dixon, Adam et al. | 2009
- 72584T
-
Computed tomography quality indexes: evaluation experienceStrocchi, Sabina / Vite, Cristina / Novario, Raffaele / Cacciatori, Marco / Frigerio, Giovanna / Conte, Leopoldo et al. | 2009
- 72584U
-
Optimizing image quality using statistical multivariate optimization methodology using desirability functionsLeong, David L. / Brennan, Patrick C. et al. | 2009
- 72584V
-
GATE simulations of CTDI for patient doseLee, Chang-Lae / Kim, Hee-Joung / Cho, Hyo-Min / Park, Hye-Suk / Yoo, A-Ram et al. | 2009
- 72584Y
-
Contrast-detail comparison between unprocessed and processed CDMAM imagesZanca, F. / Bosmans, H. / Jacobs, J. / Michielsen, K. / Sisini, F. / Nens, J. / Young, K. C. / Shaheen, E. / Jacobs, A. / Marchal, G. et al. | 2009
- 72584Z
-
A simple method for evaluating image quality of screen-film system using a high-performance digital cameraFujita, Naotoshi / Yamazaki, Asumi / Ichikawa, Katsuhiro / Kodera, Yoshie et al. | 2009
- 72585A
-
High performance tomosynthesis enabled via a GPU-based iterative reconstruction frameworkXu, Fang / Khamene, Ali / Fluck, Oliver et al. | 2009
- 72585B
-
Enhancement of mobile C-arm cone-beam reconstruction using prior anatomical modelsSadowsky, Ofri / Lee, Junghoon / Sutter, Edward G. / Wall, Simon J. / Prince, Jerry L. / Taylor, Russell H. et al. | 2009
- 72585C
-
Implementation OSEM mesh-domain SPECT reconstruction with explicit prior informationKrol, Andrzej / Vogelsang, Levon / Lu, Yao / Xu, Yuesheng / Hu, Xiaofei / Shen, Lixin / Feiglin, David / Lipson, Edward et al. | 2009
- 72585D
-
A new design for a micro-CT scannerKlaften, Matthias / Schegerer, Alexander / Tischenko, Oleg / Xu, Yuan / Förster, Thomas / Hrabé de Angelis, Martin / Hoeschen, Christoph et al. | 2009
- 72585E
-
Local cone-beam SPECT reconstruction with non-uniform attenuationChen, Yunbin / Wen, Junhai / Wang, Li / Liang, Zhengrong et al. | 2009
- 72585F
-
Fast implementation of the image reconstruction algorithm OPEDXu, Yuan / Tischenko, Oleg / Hoeschen, Christoph et al. | 2009
- 72585G
-
Exact and stable interior ROI reconstruction for radial MRIZhang, Jie / Yu, Hengyong / Corum, Curt / Garwood, Michael / Wang, Ge et al. | 2009
- 72585H
-
Monte Carlo investigation of phosphor screen optics for use in indirect-conversion detectorsLim, Chang Hwy / Shon, Cheol-Soon / Han, Jong Chul / Kim, Tae Woo / Kim, Ho Kyung et al. | 2009
- 72585I
-
Implementation of penalized-likelihood statistical reconstruction for polychromatic dual-energy CTXu, Qiong / Mou, Xuanqin / Tang, Shaojie / Hong, Wei / Zhang, Yizhai / Luo, Tao et al. | 2009
- 72585J
-
Feasibility of GPU-assisted iterative image reconstruction for mobile C-arm CTPan, Yongsheng / Whitaker, Ross / Cheryauka, Arvi / Ferguson, Dave et al. | 2009
- 72585L
-
Initial investigation of novel trajectories to improve chest wall imaging in a dedicated breast computed tomography systemCrotty, Dominic J. / McKinley, Randolph L. / Madhav, Priti / Cutler, Spencer J. / Tornai, Martin P. et al. | 2009
- 72585M
-
X-ray tube-based diffraction enhanced imaging prototype images of full-thickness breast specimens: reader study evaluationFaulconer, L. S. / Parham, C. / Connor, D. J. / Koomen, M. / Kuzmiak, C. / Pavic, D. / Livasy, C. A. / Kim, E. / Zeng, D. / Cole, E. B. et al. | 2009
- 72585N
-
Dual source CT (DSCT) imaging of obese patients: evaluation of CT number accuracy, uniformity, and noiseWalz-Flannigan, A. / Schmidt, B, / Apel, A. / Eusemann, C. / Yu, L. / McCollough, C. H. et al. | 2009
- 72585O
-
Use of effective detective quantum efficiency to optimise radiographic exposures for chest imaging with computed radiographyErtan, Ferihan / Mackenzie, Alistair / Urbanczyk, Hannah J. / Ranger, Nicole T. / Samei, Ehsan et al. | 2009
- 72585P
-
Digital radiography system using a new direct-detection flat panel detector and its system performancePark, Jong-Hwan / Kang, Won-Suk / Shin, Byung-Su / Kang, Hyun-Seung et al. | 2009
- 72585Q
-
A dynamic micro-CT scanner with a stationary mouse bed using a compact carbon nanotube field emission x-ray tubeCao, Guohua / Calderon-Colon, Xiomara / Wang, Peng / Burk, Laurel / Lee, Yueh Z. / Rajaram, Ramya / Sultana, Shabana / Lalush, David / Lu, Jianping / Zhou, Otto et al. | 2009
- 72585R
-
Dose reduction potential of the scanning geometry CT D'OR: a simulation studyde las Heras, Hugo / Tischenko, Oleg / Schlattl, Helmut / Xu, Yuan / Hoeschen, Christoph et al. | 2009
- 72585S
-
Configuration of automatic exposure control on mammography units for computed radiography to match patient dose of screen film systemsYang, Chang-Ying Joseph / Huang, Weidong et al. | 2009
- 72585T
-
Feasibility of using the micro CT imaging system as the conformal radiation therapy facility for small animalsTu, Shu-Ju / Hsieh, Hui-Ling / Chao, Tsi-Chian / Lee, Chung-Chi et al. | 2009
- 72585U
-
Calcification visibility study using combined high dose and low dose cone beam CT projectionsZhong, Y, / Lai, C. J. / Chen, L. / Han, T. / Shen, Y. / Liu, X. / Wang, T. / Ge, S. / Yi, Y. / You, Z. et al. | 2009
- 72585V
-
Dose assessment of digital tomosynthesis in pediatric imagingGislason, Amber / Elbakri, Idris A. / Reed, Martin et al. | 2009
- 72585W
-
The CNR method in scan angle optimization of tomosynthesis and its limitationsRen, Baorui / Ruth, Chris / Zhang, Yiheng / Smith, Andrew / Williams, Cornell / Polischuk, Brad / Jing, Zhenxue et al. | 2009
- 72585X
-
Investigation of the dosimetry of chest tomosynthesisSvalkvist, Angelica / Zachrisson, Sara / Månsson, Lars Gunnar / Båth, Magnus et al. | 2009
- 72585Y
-
Effects of scatter radiation on reconstructed images in digital breast tomosynthesisLiu, Bob / Li, Xinhua et al. | 2009
- 72585Z
-
Effect of non-isotropic detector blur on microcalcification detectability in tomosynthesisReiser, Ingrid S. / Nishikawa, Robert M. / Lau, Beverly A. et al. | 2009
- 725801
-
Front Matter: Volume 7258| 2009
- 725802
-
Pediatric CT and radiation: our responsibilityFrush, Donald P. et al. | 2009
- 725803
-
Low radiation dose C-arm cone-beam CT based on prior image constrained compressed sensing (PICCS): including compensation for image volume mismatch between multiple data acquisitionsNett, Brian / Tang, Jie / Aagaard-Kienitz, Beverly / Rowley, Howard / Chen, Guang-Hong et al. | 2009
- 725804
-
Patient-specific dose estimation for pediatric abdomen-pelvis CTLi, Xiang / Samei, Ehsan / Segars, W. Paul / Sturgeon, Gregory M. / Colsher, James G. / Frush, Donald P. et al. | 2009
- 725805
-
Analytical construction of 3D NPS for a cone beam CT systemBaek, Jongduk / Pelc, Norbert J. et al. | 2009
- 725806
-
Evaluation of the additive noise of a flat panel detector and its effect on cone-beam CT applicationsYang, Kai / Huang, Shih-Ying C. / Packard, Nathan J. / Boone, John M. et al. | 2009
- 725807
-
Noise analysis in intensity-weighted region-of-interest imaging for cone-beam CTCho, Seungryong / Pearson, Erik / Pelizzari, Charles A. / Pan, Xiaochuan et al. | 2009
- 725808
-
Optimization of 4D cone-beam CT: evaluation of streaking artifacts and noise with various simulated gantry rotation speedsAhmad, Moiz / Balter, Peter / Munro, Peter / Lu, Jun / Pan, Tinsu et al. | 2009
- 725809
-
Measurement of spatial and density resolutions in x-ray nanocomputed tomographyKawata, Y. / Kageyama, K. / Nakaya, Y. / Niki, N. / Umetani, K. / Yada, K. / Ohmatsu, H. / Eguchi, K. / Kaneko, M. / Moriyama, N. et al. | 2009
- 725810
-
Quantification of three-dimensional tongue motion during speech using zHARPLiu, Xiaofeng / Zhuo, Jiachen / Agarwal, Harsh / Abd-Elmoniem, Khaled Z. / Murano, Emi / Stone, Maureen / Gullapalli, Rao / Prince, Jerry L. et al. | 2009
- 725811
-
Detection of iron overload through neutron stimulated emission computed tomography: a sensitivity analysis studyKapadia, Anuj J. / Agasthya, Greeshma A. / Tourassi, Georgia D. et al. | 2009
- 725812
-
Iterative finite-element-based inversion for quantified detection of molecular targets using optoacoustic tomographyJetzfellner, Thomas / Razansky, Daniel / Rosenthal, Amir / Schulz, Ralf / Englmeier, K.-H. / Ntziachristos, Vasilis et al. | 2009
- 725813
-
Simulating ultra-wideband imaging for the early detection of tissue injuryNiu, Weihong / Hlavaty, Kelan / Tanska, Daria / Tseng, Nancy / Li, Jia / Penprase, Barbara et al. | 2009
- 725814
-
Active pixel and photon counting imagers based on poly-Si TFTs: rewriting the rule book on large area flat panel x-ray devicesAntonuk, Larry E. / Koniczek, Martin / El-Mohri, Youcef / Zhao, Qihua et al. | 2009
- 725815
-
Characterization of current programmed amorphous silicon active pixel sensor readout circuit for dual mode diagnostic digital x-ray imagingSafavian, Nader / Yazdandoost, M. / Wu, D. / Sultana, A. / Izadi, M. H. / Karim, K. S. / Nathan, A. / Rowlands, J. A. et al. | 2009
- 725816
-
Amorphous selenium detector utilizing a Frisch grid for photon-counting imaging applicationsGoldan, A. H. / Fang, Y. / Karim, K. S. / Tousignant, O. / Mani, H. / Laperrière, L. et al. | 2009
- 725817
-
Component analysis of a new solid state x-ray image intensifier (SSXII) using photon transfer and instrumentation noise equivalent exposure (INEE) measurementsKuhls-Gilcrist, Andrew / Bednarek, Daniel R. / Rudin, Stephen et al. | 2009
- 725818
-
Quantitative radiography enabled by slot collimation and a novel scatter correction technique on a large-area flat panel x-ray detectorYue, Meghan L. / Boden, Adam E. / Sabol, John M. et al. | 2009
- 725819
-
Noise and signal detection in digital x-ray detectors using the spatial definition of SNRKyprianou, Iacovos S. / Badano, Aldo / Park, Subok / Liu, Haimo / Myers, Kyle J. et al. | 2009
- 725820
-
Scatter correction for x-ray conebeam CT using one-dimensional primary modulationZhu, Lei / Gao, Hewei / Bennett, N. Robert / Xing, Lei / Fahrig, Rebecca et al. | 2009
- 725821
-
Optimal energy thresholds and weights for separating materials using photon counting x-ray detectors with energy discriminating capabilitiesWang, Adam S. / Pelc, Norbert J. et al. | 2009
- 725822
-
X-ray multisource for medical imagingFrutschy, Kris / De Man, Bruno / Edic, Pete / Lounsberry, Brian / Neculaes, Bogdan / Zou, Yun / Inzinna, Lou / Conway, Ken / Zhang, Xi / Cao, Yang et al. | 2009
- 725823
-
SNR efficient 3D reconstruction algorithm for multi-source inverse geometry CT systemBaek, Jongduk / Pelc, Norbert J. et al. | 2009
- 725824
-
Characterization of a novel photon counting detector for clinical CT: count rate, energy resolution, and noise performanceBarber, William C. / Nygard, Einar / Iwanczyk, Jan S. / Zhang, Mengxi / Frey, Eric C. / Tsui, Benjamin M. W. / Wessel, Jan C. / Malakhov, Nail / Wawrzyniak, Gregor / Hartsough, Neal E. et al. | 2009
- 725825
-
Photon-counting CT with silicon detectors: feasibility for pediatric imagingYveborg, Moa / Xu, Cheng / Fredenberg, Erik / Danielsson, Mats et al. | 2009
- 725826
-
Performance comparison between compressed sensing and statistical iterative reconstruction algorithmsTang, Jie / Nett, Brian / Chen, Guang-Hong et al. | 2009
- 725827
-
Boundary reconstruction in limited-angle x-ray phase-contrast tomographyAnastasio, Mark A. / Sidky, Emil Y. / Pan, Xiaochuan / Chou, Cheng-Ying et al. | 2009
- 725828
-
A dual formulation of a penalized maximum likelihood x-ray CT reconstruction problemXu, Jingyan / Taguchi, Katsuyuki / Gullberg, Grant T. / Tsui, Benjamin M. W. et al. | 2009
- 725829
-
Noise properties of iterative reconstruction techniques in low-dose CT scansDo, Synho / Kalra, Mannudeep K. / Liang, Zhuangli / Karl, W. Clem. / Brady, Thomas J. / Pien, Homer et al. | 2009
- 725830
-
Imaging technique optimization of tungsten anode FFDM systemChen, Biao / Smith, Andrew P. / Jing, Zhenxue / Ingal, Elena et al. | 2009
- 725831
-
Digital breast tomosynthesis (DBT) versus full field digital mammography (FFDM): comparison of a system performance using a contrast detail phantomNitrosi, A. / Borasi, G. / Bertolini, M. / Botti, A. / Tassoni, D. / Strocchi, S. et al. | 2009
- 725832
-
Cardiac imaging with multi-sector data acquisition in volumetric CT: variation of effective temporal resolution and its potential clinical consequencesTang, Xiangyang / Hsieh, Jiang / Taha, Basel H. / Vass, Melissa L. / Seamans, John L. / Okerlund, Darin R. et al. | 2009
- 725833
-
Advanced processing for motion-compensated reconstruction in cardiac cone-beam CTvan Stevendaal, Udo / Forthmann, Peter / Köhler, Thomas / von Berg, Jens / Lorenz, Cristian / Grass, Michael et al. | 2009
- 725834
-
A second pass gated reconstruction scheme with conjugate weightsErhard, Klaus / Grass, Michael et al. | 2009
- 725835
-
A cardiac phantom study on quantitative correction of coronary calcium score on multi-detector, dual source, and electron beam tomography for velocity, calcification density, and acquisition timeGreuter, Marcel J. W. / Groen, Jaap M. / Nicolai, Lieuwe J. / Dijkstra, Hildebrand / Oudkerk, Matthijs et al. | 2009
- 725836
-
Diagnostic quality of time-averaged ECG-gated CT dataKlein, Almar / Oostveen, Luuk J. / Greuter, Marcel J. W. / Hoogeveen, Yvonne / Schultze Kool, Leo J. / Slump, Cornelis H. / Renema, W. Klaas Jan et al. | 2009
- 725837
-
An online cross-scatter correction algorithm for dual-source CT: effects on CT number accuracy and noiseEusemann, Christian D. / Apel, Anja / Schmidt, Bernhard / Walz-Flannigan, Alisa I. / Jacobsen, Megan C. / Stierstorfer, Karl / Flohr, Thomas G. / McCollough, Cynthia H. et al. | 2009
- 725838
-
Iterative scatter correction for x-ray cone-beam CT with semi-transparent beam stop arrayYan, Hao / Mou, Xuanqin / Tang, Shaojie / Chen, Xi et al. | 2009
- 725839
-
Analytical scatter estimation for cone-beam computed tomographyIngleby, Harry R. / Elbakri, Idris A. / Rickey, Daniel W. / Pistorius, Stephen et al. | 2009
- 725840
-
Scatter correction algorithm without extra exposure for dual-energy digital mammographyChen, Xi / Mou, Xuanqin / Yan, Hao / Yu, Hengyong / Zhang, Lei et al. | 2009
- 725841
-
A material decomposition method for dual energy micro-CTJohnston, S. M. / Johnson, G. A. / Badea, C. T. et al. | 2009
- 725842
-
Dual-energy performance of dual kVp in comparison to dual-layer and quantum-counting CT system conceptsKappler, S. / Grasruck, M. / Niederlöhner, D. / Strassburg, M. / Wirth, S. et al. | 2009
- 725843
-
Fast kVp switching CT imaging of a dynamic cardiac phantomPack, Jed D. / Langan, David A. / Wu, Xiaoye / Xu, Dan / Benson, Thomas M. / Schmitz, Andrea M. / Tkaczyk, J. Eric / Pavlicek, William / Boltz, Thomas F. / Payden, Robert et al. | 2009
- 725844
-
Advanced material separation technique based on dual energy CT scanningZamyatin, Alexander A. / Natarajan, Anusha / Zou, Yu et al. | 2009
- 725845
-
Monochromatic CT image representation via fast switching dual kVpWu, Xiaoye / Langan, David A. / Xu, Dan / Benson, Thomas M. / Pack, Jed D. / Schmitz, Andrea M. / Tkaczyk, Eric J. / Leverentz, Jaynne / Licato, Paul et al. | 2009
- 725846
-
Development of a high-speed CT imaging system using EMCCD cameraThacker, Samta C. / Yang, Kai / Packard, Nathan / Gaysinskiy, Valeriy / Burkett, George / Miller, Stuart / Boone, John M. / Nagarkar, Vivek et al. | 2009
- 725847
-
Stationary micro-CT scanner using a distributed multi-beam field emission x-ray source: a feasibility studyPeng, R. / Zhang, J. / Calderon-Colon, X. / Wang, S. / Sultana, S. / Chang, S. / Lu, J. P. / Zhou, O. et al. | 2009
- 725848
-
Liquid lens confocal microscopy with advanced signal processing for higher resolution 3D imagingRiza, Nabeel A. / Sheikh, Mumtaz A. et al. | 2009
- 725850
-
Image quality of a cone beam O-arm 3D imaging systemZhang, Jie / Weir, Victor / Lin, Jingying / Hsiung, Hsiang / Ritenour, E. Russell et al. | 2009
- 725852
-
MTF compensation for digital radiography system with indirect conversion flat panel detectorZhang, Wei / Souchay, Henri / Yang, Chao et al. | 2009
- 725854
-
Tomographic mesh generation for OSEM reconstruction of SPECT imagesLu, Yao / Yu, Bo / Vogelsang, Levon / Krol, Andrzej / Xu, Yuesheng / Hu, Xiaofei / Feiglin, David et al. | 2009
- 725855
-
Dose reduction in digital breast tomosynthesis using a penalized maximum likelihood reconstructionDas, Mini / Gifford, Howard / O'Connor, Michael / Glick, Stephen J. et al. | 2009
- 725856
-
Implementation of an effective KL domain penalized weighted least-squares sinogram restoration for low-dose CT colonographyFan, Yi / Wang, Jing / Lu, Hongbing / Liang, Zhengrong et al. | 2009
- 725857
-
Spatio-temporal filtration of dynamic CT data using diffusion filtersBruder, H. / Raupach, R. / Klotz, E. / Stierstorfer, K. / Flohr, T. et al. | 2009
- 725858
-
RGBA packing for fast cone beam reconstruction on the GPUIno, Fumihiko / Yoshida, Seiji / Hagihara, Kenichi et al. | 2009
- 725859
-
Breast tomosynthesis reconstruction with a multi-beam x-ray sourceChen, Ying / Zhou, Weihua / Yang, Guang / Qian, Xin / Lu, Jianping / Zhou, Otto et al. | 2009
- 725860
-
Ghosting and its recovery mechanisms in multilayer selenium detectors for mammographyMahmood, S. A. / Kabir, M. Z. / Tousignant, O. / Mani, H. et al. | 2009
- 725862
-
Erratum for 72585W: The CNR method in scan angle optimization of tomosynthesis and its limitationsRen, Baorui / Ruth, Chris / Zhang, Yiheng / Smith, Andrew / Williams, Cornell / Polischuk, Brad / Jing, Zhenxue et al. | 2009
-
Analytical construction of 3D NPS for a cone beam CT system [7258-04]Baek, J. / Pelc, N.J. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Enhanced computer simulation of CT mammography using a flat-panel imager [7258-18]Didier, C.S. / O Connor, J.M. / Chen, Y. / Glick, S.J. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Volume and tissue composition preserving deformation of breast CT images to simulate breast compression in mammographic imaging [7258-19]Han, T. / Chen, L. / Lai, C. / Liu, X. / Shen, Y. / Zhong, Y. / Ge, S. / Yi, Y. / Wang, T. / Shaw, C.C. et al. | 2009
-
Advanced reconstruction of attenuation maps using SPECT emission data only [7258-31]Salomon, A. / Goedicke, A. / Aach, T. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
SKE/BKE task-based methodology for calculating Hotelling observer SNR in mammography [7258-48]Liu, H. / Kyprianou, I.S. / Badano, A. / Myers, K.J. / Jennings, R.J. / Park, S. / Kaczmarek, R.V. / Chakrabarti, K. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Image-based iterative compensation of motion artifacts in computed tomography [7258-67]Schretter, C. / Neukirchen, C. / Rose, G. / Bertram, M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Optimal energy thresholds and weights for separating materials using photon counting x-ray detectors with energy discriminating capabilities [7258-72]Wang, A.S. / Pelc, N.J. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Geometric calibration of detectors with discrete irregularities for computed tomography (Honorable Mention Poster Award) [7258-85]Holt, K.M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Real-time compression of raw computed tomography data: technology, architecture, and benefits [7258-88]Wegener, A. / Chandra, N. / Ling, Y. / Senzig, R. / Herfkens, R. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
An experimental cone-beam micro-CT system for small animal imaging [7258-99]Zhu, S. / Tian, J. / Yan, G. / Qin, C. / Liu, J. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Pixel-structured scintillators for digital x-ray imaging (Honorable Mention Poster Award) [7258-133]Yun, S.M. / Lim, C.H. / Kim, T.W. / Kim, H.K. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
A new design for a micro-CT scanner [7258-201]Klaften, M. / Schegerer, A. / Tischenko, O. / Xu, Y. / Forster, T. / de Angelis, M.H. / Hoeschen, C. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Initial investigation of novel trajectories to improve chest wall imaging in a dedicated breast computed tomography system [7258-209]Crotty, D.J. / McKinley, R.L. / Madhav, P. / Cutler, S.J. / Tornai, M.P. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Quantization of liver tissue in dual kVp computed tomography using linear discriminant analysis [7258-15]Tkaczyk, J.E. / Langan, D. / Wu, X. / Xu, D. / Benson, T. / Pack, J.D. / Schmitz, A. / Hara, A. / Palicek, W. / Licato, P. et al. | 2009
-
Optimized lesion detection in digital breast tomosynthesis [7258-24]Chawla, A.S. / Samel, E. / Lo, J.Y. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Quantitative evaluation of noise reduction algorithms for very low dose renal CT perfusion imaging [7258-64]Liu, X. / Primak, A.N. / Yu, L. / Li, H. / Krier, J.D. / Lerman, L.O. / McCollough, C.H. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Interactive GPU-accelerated image reconstruction in cone-beam CT [7258-81]Hillebrand, L. / Lapp, R.M. / Kyriakou, Y. / Kalender, W.A. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Imaging technique optimization of tungsten anode FFDM system [7258-108]Chen, B. / Smith, A.P. / Jing, Z. / Ingal, E. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
A second pass gated reconstruction scheme with conjugate weights [7258-112]Erhard, K. / Grass, M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
An online cross-scatter correction algorithm for dual-source CT: effects on CT number accuracy and noise [7258-115]Eusemann, C.D. / Apel, A. / Schmidt, B. / Walz-Flannigan, A.I. / Jacobsen, M.C. / Stierstorfer, K. / Flohr, T.G. / McCollough, C.H. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
High-contrast artifact reduction in cone beam computed tomography by using geometric techniques [7258-119]Noel, P.B. / Xu, J. / Hoffmann, K.R. / Corso, J.J. / Schafer, S. / Walczak, A.M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Flat detector ghost image reduction by UV irradiation [7258-128]Snoeren, R.M. / Steinhauser, H. / Alving, L. / Stouten, H. / de With, P.H.N. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
A counting and integrating pixel readout chip for amorphous selenium direct radiation detectors for medical imaging applications (Honorable Mention Poster Award) [7258-129]Goldan, A.H. / Hadji, B. / Karim, K.S. / DeCrescenzo, G. / Rowlands, J.A. / Tousignant, O. / Laperriere, L. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Optimized operation and offset corrections for a battery-powered wireless digital x-ray detector [7258-135]Topfer, K. / Dehority, J. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Enhanced discrimination of calcified and soft arterial plaques using computed tomography with a multi-energy-window photon counting x-ray detector [7258-143]Wang, X. / Xu, J. / Taguchi, K. / Patt, B.E. / Wagenaar, D.J. / Frey, E.C. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Monochromatic CT image representation via fast switching dual kVp [7258-152]Wu, X. / Langan, D.A. / Xu, D. / Benson, T.M. / Pack, J.D. / Schmitz, A.M. / Tkaczyk, E.J. / Leverentz, J. / Licato, P. / SPIE (Society) et al. | 2009
-
Image quality evaluation of a LightSpeed CT750 HD computed tomography system [7258-177]Fan, J. / Dong, F. / Sainath, P. / Hsieh, J. / Tang, X. / Toth, T. / Li, B. / Crandall, P. / Senzig, R. / Dixon, A. et al. | 2009
-
A simple method for evaluating image quality of screen-film system using a high-performance digital camera [7258-186]Fujita, N. / Yamazaki, A. / Ichikawa, K. / Kodera, Y. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Implementation OSEM mesh-domain SPECT reconstruction with explicit prior information [7258-200]Krol, A. / Vogelsang, L. / Lu, Y. / Xu, Y. / Hu, X. / Shen, L. / Feiglin, D. / Lipson, E. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Conference CommitteeSPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Four-dimensional cardiac reconstruction from rotational x-ray sequences: first results for 4D coronary angiography [7258-10]Hansis, E. / Schomberg, H. / Erhard, K. / Dossel, O. / Grass, M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Measurement of spatial and density resolutions in x-ray nanocomputed tomography [7258-08]Kawata, Y. / Kageyama, K. / Nakaya, Y. / Niki, N. / Umetani, K. / Yada, K. / Ohmatsu, H. / Eguchi, K. / Kaneko, M. / Moriyama, N. et al. | 2009
-
Estimating breast tomosynthesis performance in detection tasks with variable-background phantoms [7258-23]Young, S. / Park, S. / Anderson, S.K. / Badano, A. / Myers, K.J. / Bakic, P. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Noise analysis of full field digital mammography systems [7258-46]Ravaglia, V. / Bouwman, R. / Young, K. / van Engen, R. / Lazzari, B. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
A photon-counting detector for dual-energy breast tomosynthesis [7258-54]Fredenberg, E. / Lundqvist, M. / Aslund, M. / Hemmendorff, M. / Cederstrom, B. / Danielsson, M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Imaging of small children with a prototype for photon counting tomosynthesis [7258-59]del Risco Norrlid, L. / Fredenberg, E. / Hemmendorff, M. / Jackowski, C. / Danielsson, M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Image-based online correction of misalignment artifacts in cone-beam CT [7258-66]Kyriakou, Y. / Lapp, R.M. / Hillebrand, L. / Ertel, D. / Kalender, W.A. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Elimination of blooming artifacts off stents by dual energy CT [7258-116]Zou, Y. / Silver, M.D. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Efficient scatter correction using asymmetric kernels [7258-70]Star-Lack, J. / Sun, M. / Kaestner, A. / Hassanein, R. / Virshup, G. / Berkus, T. / Oelhafen, M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Noise correlation in CBCT projection data and its application for noise reduction in low-dose CBCT [7258-84]Wang, J. / Chai, A. / Xing, L. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
A noise decomposition method for image quality analysis of medical radiography detectors [7258-96]Tahli, S.A. / Maack, I. / Koch, A. / Herrmann, C. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
4D micro-CT-based perfusion imaging in small animals (Cum Laude Poster Award) [7258-100]Badea, C.T. / Johnston, S.M. / Lin, M. / Hedlund, L.W. / Johnson, G.A. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Clinical micro-CT for dental imaging [7258-103]Youn, H. / Cho, M.K. / Shon, C.-S. / Cho, B.H. / Kim, C.H. / Kim, H.K. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Preliminary feasibility of dedicated breast CT with an inverse geometry [7258-106]Schmidt, T.G. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Betacam: a commercial approach to beta -autoradiography [7258-136]Cabello, J. / Holland, A. / Holland, K. / Bailey, A. / Kitchen, I. / Wells, K. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Image-based dual energy CT improvements using Gram-Schmidt method [7258-139]Park, K.-K. / Pavlicek, W. / Boltz, T. / Paden, R. / Hara, A. / Akay, M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Investigation of quantitative polychromatic x-ray phase-contrast tomography for tissue characterization [7258-158]Chou, C.-Y. / Zysk, A.M. / Anastasio, M.A. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
RGBA packing for fast cone beam reconstruction on the GPU [7258-196]Ino, F. / Yoshida, S. / Hagihara, K. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
High performance tomosynthesis enabled via a GPU-based iterative reconstruction framework [7258-198]Xu, F. / Khamene, A. / Fluck, O. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Dose reduction potential of the scanning geometry CT D'OR: a simulation study [7258-215]de las Heras, H. / Tischenko, O. / Schlattl, H. / Xu, Y. / Hoeschen, C. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
In Memoriam: Robert F. Wagner (1938-2008)SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Nonuniform angular dose distribution in digital breast tomosynthesis for increased conspicuity of small high contrast objects [7258-25]Hu, Y.-H. / Zhao, W. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Computerized 3D breast phantom with enhanced high-resolution detail [7258-27]Li, C.M. / Segars, W.P. / Lo, J.Y. / Veress, A.I. / Boone, J.M. / Dobbins, J.T. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Active pixel and photon counting imagers based on poly-Si TFTs: rewriting the rule book on large area flat panel x-ray devices [7258-39]Antonuk, L.E. / Koniczek, M. / El-Mohri, Y. / Zhao, Q. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Component analysis of a new solid state x-ray image intensifier (SSXII) using photon transfer and instrumentation noise equivalent exposure (INEE) measurements [7258-42]Kuhls-Gilcrist, A. / Bednarek, D.R. / Rudin, S. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Noise and signal detection in digital x-ray detectors using the spatial definition of SNR [7258-44]Kyprianou, I.S. / Badano, A. / Park, S. / Liu, H. / Myers, K.J. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Scatter correction for x-ray conebeam CT using one-dimensional primary modulation [7258-71]Zhu, L. / Gao, H. / Bennett, N.R. / Xing, L. / Fahrig, R. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
A dual formulation of a penalized maximum likelihood x-ray CT reconstruction problem [7258-79]Xu, J. / Taguchi, K. / Gullberg, G.T. / Tsui, B.M.W. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Volumetric soft tissue brain imaging on xCAT, a mobile flat-panel x-ray CT system [7258-91]Zbijewski, W. / Stayman, J.W. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Wavelet based de-noising methods for local SPECT reconstruction with nonuniform attenuation [7258-95]Wang, L. / Wen, J. / Yang, J. / Chen, Y. / Liang, Z. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Evaluating low pass filters on SPECT reconstructed cardiac orientation estimation [7258-97]Dwivedi, S. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Study of signal-to-noise ratio in digital mammography [7258-107]Kato, Y. / Fujita, N. / Kodera, Y. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Iterative scatter correction for x-ray cone-beam CT with semi-transparent beam stop array [7258-117]Yan, H. / Mou, X. / Tang, S. / Chen, X. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Advanced a-Se film with high sensitivity and heat resistance for x-ray detectors (Honorable Mention Poster Award) [7258-131]Ogusu, K. / Nakane, O. / Igasaki, Y. / Okamura, Y. / Yamada, S. / Hirai, T. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Dual energy with dual source CT and kVp switching with single source CT: a comparison of dual energy performance [7258-138]Grasruck, M. / Kappler, S. / Reinwand, M. / Stierstorfer, K. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Dual-energy performance of dual kVp in comparison to dual-layer and quantum-counting CT system concepts [7258-149]Kappler, S. / Grasruck, M. / Niederlohner, D. / Strassburg, M. / Wirth, S. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
A novel method to reduce data acquisition time in differential phase contrast: computed tomography using compressed sensing [7258-157]Qi, Z. / Zambelli, J. / Bevins, N. / Chen, G.-H. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
MEG beamforming: magnetic source imaging [7258-159]Lei, T. / Roberts, T.P.L. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Analysis of the spectrum in phase-contrast mammography [7258-163]Zysk, A.M. / Xu, Q. / de Sisternes, L. / Brankov, J.G. / Wernick, M.N. / Anastasio, M.A. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Effect of non-isotropic detector blur on microcalcification detectability in tomosynthesis [7258-225]Reiser, I.S. / Nishikawa, R.M. / Lau, B.A. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Low radiation dose C-arm cone-beam CT based on prior image constrained compressed sensing (PICCS): including compensation for image volume mismatch between multiple data acquisitions [7258-02]Nett, B. / Tang, J. / Aagaard-Kienitz, B. / Rowley, H. / Chen, G.-H. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Three-dimensional imaging properties of rotation-free square and hexagonal micro-CT systems [7258-17]Quan, E. / Lalush, D.S. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
HyperSPECT: a new system for pre-clinical imaging in vivo [7258-32]Tibbelin, S. / Nillius, P. / Cederstrom, B. / Danielsson, M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Iterative finite-element-based inversion for quantified detection of molecular targets using optoacoustic tomography [7258-37]Jetzfellner, T. / Razansky, D. / Rosenthal, A. / Schulz, R. / Englmeier, K.-H. / Ntziachristos, V. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Characterization of current programmed amorphous silicon active pixel sensor readout circuit for dual mode diagnostic digital x-ray imaging [7258-134]Safavian, N. / Yazdandoost, M. / Wu, D. / Sultana, A. / Izadi, M.H. / Karim, K.S. / Nathan, A. / Rowlands, J.A. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Amorphous selenium detector utilizing a Frisch grid for photon-counting imaging applications [7258-41]Goldan, A.H. / Fang, Y. / Karim, K.S. / Tousignant, O. / Mani, H. / Laperriere, L. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Predicting contrast detail performance from objective measurements in digital mammography [7258-47]Young, K.C. / Alsager, A. / Dance, D.R. / Oduko, J.M. / Gundogdu, O. / Spyrou, N.M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
SNR efficient 3D reconstruction algorithm for multi-source inverse geometry CT system [7258-74]Baek, J. / Pelc, N.J. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Effect of detector time delay and its correction in multiple source computed tomography [7258-83]Thran, A. / Forthmann, P. / Proksa, R. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Simultaneous activity and attenuation reconstruction in PET: applying partially known attenuation [7258-86]Furuie, S.S. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Image reconstruction for a stationary digital breast tomosynthesis system [7258-92]Rajaram, R. / Yang, G. / Quan, E. / Frederick, B. / Lalush, D.S. / Zhou, O.Z. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Toward region of interest computer tomography [7258-94]Schafer, S. / Noel, P.B. / Walczak, A.M. / Hoffmann, K.R. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Systematic scanner variability of patient CT attenuation measurements [7258-98]Judy, P.F. / Nawfel, R.D. / Silverman, S.G. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Attenuation and image noise level based online z-axis tube current modulation for CT scans independent with localizer radiograph: simulation study and results [7258-101]Tian, Y. / Chen, M. / Kong, J. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Reduction of artifacts due to multiple metallic objects in computed tomography [7258-124]Jeong, K.Y. / Ra, J.B. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Feasibility study of CMOS detectors for mammography [7258-40]Han, J.C. / Yun, S. / Lim, C.H. / Kim, T.W. / Kim, H.K. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Empirical projection-based basis-component decomposition method [7258-145]Brendel, B. / Roessl, E. / Schlomka, J.-P. / Proksa, R. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Marginal adaptation analysis performed with en face optical coherence tomography in fixed partial dentures [7258-166]Sinescu, C. / Negrutiu, M.L. / Antonie, S. / Dobre, G. / Bradu, A. / Hughes, M. / Rominu, M. / Podoleanu, A.G. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Effect of masticatory load on cracks deflection/penetration investigated with en face optical coherence tomography in ceramic fixed partial dentures [7258-169]Sinescu, C. / Negrutiu, M.L. / Marsavina, L. / Negru, R. / Hluscu, M. / Caplescu, C. / Bradu, A. / Hughes, M. / Rominu, M. / Podoleanu, A.G. et al. | 2009
-
Image quality evaluation of direct-conversion digital mammography system with new dual a-Se layer detector [7258-174]Kuwabara, T. / Iwasaki, N. / Sendai, T. / Furue, R. / Agano, T. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Optimizing image quality using statistical multivariate optimization methodology using desirability functions [7258-179]Leong, D.L. / Brennan, P.C. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Exact and stable interior ROI reconstruction for radial MRI [7258-204]Zhang, J. / Yu, H. / Corum, C. / Garwood, M. / Wang, G. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Monte Carlo investigation of phosphor screen optics for use in indirect-conversion detectors [7258-205]Lim, C.H. / Shon, C.-S. / Han, J.C. / Kim, T.W. / Kim, H.K. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Feasibility of GPU-assisted iterative image reconstruction for mobile C-arm CT [7258-207]Pan, Y. / Whitaker, R. / Cheryauka, A. / Ferguson, D. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Evaluation of the additive noise of a flat panel detector and its effect on cone-beam CT applications [7258-05]Yang, K. / Huang, S.-Y.C. / Packard, N.J. / Boone, J.M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Quantitative radiography enabled by slot collimation and a novel scatter correction technique on a large-area flat panel x-ray detector [7258-43]Yue, M.L. / Boden, A.E. / Sabol, J.M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
X-ray multisource for medical imaging [7258-73]Frutschy, K. / De Man, B. / Edic, P. / Lounsberry, B. / Neculaes, B. / Zou, Y. / Inzinna, L. / Conway, K. / Zhang, X. / Cao, Y. et al. | 2009
-
Performance comparison between compressed sensing and statistical iterative reconstruction algorithms [7258-77]Tang, J. / Nett, B. / Chen, G.-H. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
CBCT/CBDT equipped with the x-ray projection system for image-guided proton therapy [7258-102]Cho, M.K. / Kim, J.S. / Cho, Y.-B. / Youn, H. / Park, S.Y. / Cho, S. / Kim, H.K. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
A cardiac phantom study on quantitative correction of coronary calcium score on multi-detector, dual source, and electron beam tomography for velocity, calcification density, and acquisition time [7258-113]Greuter, M.J.W. / Groen, J.M. / Nicolai, L.J. / Dijkstra, H. / Oudkerk, M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Real time implementation of distortion corrections for a tiled EMCCD-based solid state x-ray image intensifier (SSXII) [7258-120]Keleshis, C. / Hoffmann, K.R. / Lee, J. / Hamwi, H. / Wang, W. / Ionita, C.N. / Bednarek, D.R. / Verevkin, A. / Rudin, S. / SPIE (Society) et al. | 2009
-
Reduction of aliasing artifacts in tomographic images [7258-125]Tischenko, O. / Xu, Y. / Goetzfried, T. / Bogner, L. / Hoeschen, C. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Three-dimensional photoacoustic tomography of finger joint: from phantom experiment to in vivo study [7258-165]Sun, Y. / Jiang, H. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
A new linear least squares method for T1 estimation from SPGR signals with multiple TRs [7258-173]Chang, L.-C. / Koay, C.G. / Basser, P.J. / Pierpaoli, C. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
The effect of dose reductions on lesion detection in head CT [7258-175]Elojeimy, S. / Huda, W. / Ogden, K.M. / Owen, R. / Samei, E. / Rumboldt, Z. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Contrast-detail comparison between unprocessed and processed CDMAM images [7258-184]Zanca, F. / Bosmans, H. / Jacobs, J. / Michielsen, K. / Sisini, F. / Nens, J. / Young, K.C. / Shaheen, E. / Jacobs, A. / Marchal, G. et al. | 2009
-
Implementation of penalized-likelihood statistical reconstruction for polychromatic dual-energy CT [7258-206]Xu, Q. / Mou, X. / Tang, S. / Hong, W. / Zhang, Y. / Luo, T. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Use of effective detective quantum efficiency to optimise radiographic exposures for chest imaging with computed radiography (Honorable Mention Poster Award) [7258-212]Ertan, F. / Mackenzie, A. / Urbanczyk, H.J. / Ranger, N.T. / Samei, E. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
A dynamic micro-CT scanner with a stationary mouse bed using a compact carbon nanotube field emission x-ray tube [7258-214]Cao, G. / Calderon-Colon, X. / Wang, P. / Burk, L. / Lee, Y.Z. / Rajaram, R. / Sultana, S. / Lalush, D. / Lu, J. / Zhou, O. et al. | 2009
-
Effects of scatter radiation on reconstructed images in digital breast tomosynthesis [7258-224]Liu, B. / Li, X. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Pediatric CT and radiation: our responsibility (Keynote Paper) [7258-01]Frush, D.P. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
The effect of lag on image quality for a digital breast tomosynthesis system [7258-26]Mainprize, J.G. / Wang, X. / Yaffe, M.J. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Direct-conversion 50 μm pixel-pitch detector for digital mammography using amorphous selenium as a photoconductive switching layer for signal charge readout [7258-53]Irisawa, K. / Yamane, K. / Imai, S. / Ogawa, M. / Shouji, T. / Agano, T. / Hosoi, Y. / Hayakawa, T. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Analysis of lung nodule detectability and anatomical clutter in tomosynthesis imaging of the chest [7258-57]Yoon, S. / Gang, J.G. / Tward, D.J. / Siewerdsen, J.H. / Fahrig, R. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Spurious structures created by interpolation-based CT metal artifact reduction [7258-69]Muller, J. / Buzug, T.M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
GPU-accelerated SART reconstruction using the CUDA programming environment [7258-82]Keck, B. / Hofmann, H. / Scherl, H. / Kowarschik, M. / Hornegger, J. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Advanced processing for motion-compensated reconstruction in cardiac cone-beam CT (Honorable Mention Poster Award) [7258-111]van Stevendaal, U. / Forthmann, P. / Kohler, T. / von Berg, J. / Lorenz, C. / Grass, M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Characterization of bias induced metastability of amorphous silicon thin film transistor based passive pixel sensor switch and its impact on biomedical x-ray imaging application [7258-137]Sultana, A. / Safavian, N. / Izadi, M.H. / Karim, K.S. / Rowlands, J.A. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Effect of subdicing on the dispersion and resonance behavior of elastic guided waves in 1D array ultrasound transducers [7258-170]Cortes, D.H. / Datta, S.K. / Mukdadi, O.M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Modification of the NEMA XR21-2000 cardiac phantom for testing of imaging systems used in endovascular image guided interventions [7258-176]Ionita, C.N. / Dohatcu, A. / Jain, A. / Keleshis, C. / Hoffmann, K.R. / Bednarek, D.R. / Rudin, S. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Computed tomography quality indexes: evaluation experience [7258-178]Strocchi, S. / Vite, C. / Novario, R. / Cacciatori, M. / Frigerio, G. / Conte, L. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Fast implementation of the image reconstruction algorithm OPED [7258-203]Xu, Y. / Tischenko, O. / Hoeschen, C. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Dual source CT (DSCT) imaging of obese patients: evaluation of CT number accuracy, uniformity, and noise [7258-211]Walz-Flannigan, A. / Schmidt, B. / Apel, A. / Yu, L. / McCollough, C.H. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Ghosting and its recovery mechanisms in multilayer selenium detectors for mammography [7258-226]Mahmood, S.A. / Kabir, M.Z. / Tousignant, O. / Mani, H. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Optimization of 4D cone-beam CT: evaluation of streaking artifacts and noise with various simulated gantry rotation speeds [7258-07]Ahmad, M. / Balter, P. / Munro, P. / Lu, J. / Pan, T. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
High temporal resolution cardiac cone-beam CT using a slowly rotating C-arm gantry [7258-11]Chen, G.-H. / Tang, J. / Nett, B. / Leng, S. / Zambelli, J. / Qi, Z. / Bevins, N. / Reeder, S. / Rowley, H. / SPIE (Society) et al. | 2009
-
Detection of iron overload through neutron stimulated emission computed tomography: a sensitivity analysis study [7258-36]Kapadia, A.J. / Agasthya, G.A. / Tourassi, G.D. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Optimal binary coding matrices for multiplexed x-ray imaging [7258-63]Lalush, D.S. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Characterization of a novel photon counting detector for clinical CT: count rate, energy resolution, and noise performance [7258-75]Barber, W.C. / Nygard, E. / Iwanczyk, J.S. / Zhang, M. / Frey, E.C. / Tsui, B.M.W. / Wessel, J.C. / Malakhov, N. / Wawrzyniak, G. / Hartsough, N.E. et al. | 2009
-
Attenuation compensation in mesh-domain OSEM SPECT reconstruction [7258-126]Vogelsang, L. / Lu, Y. / Yu, B. / Krol, A. / Xu, Y. / Hu, X. / Feiglin, D. / Lipson, E. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
How many x-ray photons can be scattered from a SPECT/CT room to an adjacent gamma camera? [7258-127]Cao, Z. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Pre-reconstruction three-material decomposition in dual-energy CT [7258-142]Yu, L. / Liu, X. / McCollough, C.H. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Linearity between CT number and iodine concentration and application to improving accuracy of CT number in slow kV-switching dual energy CT [7258-146]Zou, Y. / Silver, M.D. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Dose efficiency consideration for volume-of-interest breast imaging using x-ray differential phase-contrast CT [7258-161]Cai, W. / Ning, R. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
GATE simulations of CTDI for patient dose [7258-180]Lee, C.-L. / Kim, H.-J. / Cho, H.-M. / Park, H.-S. / Yoo, A.-R. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Image quality of a cone beam O-arm 3D imaging system [7258-187]Zhang, J. / Weir, V. / Lin, J. / Hsiung, H. / Ritenour, E.R. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Implementation of an effective KL domain penalized weighted least-squares sinogram restoration for low-dose CT colonography [7258-194]Fan, Y. / Wang, J. / Lu, H. / Liang, Z. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Calcification visibility study using combined high dose and low dose cone beam CT projections [7258-218]Zhong, Y. / Lai, C.J. / Chen, L. / Han, T. / Shen, Y. / Liu, X. / Wang, T. / Ge, S. / Yi, Y. / You, Z. et al. | 2009
-
Flash imaging in dual source CT (DSCT) [7258-12]Bruder, H. / Petersilka, M. / Mehldau, H. / Heidinger, W. / Allmendinger, T. / Schmidt, B. / Raupach, R. / Thierfelder, C. / Stierstorfer, K. / Flohr, T. et al. | 2009
-
Kyphoplasty interventions using a navigation system and C-arm CT data: first clinical results [7258-13]Hoheisel, M. / Skalej, M. / Beuing, O. / Bill, U. / Klingenbeck-Regn, K. / Petzold, R. / Nagel, M.H. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Cone-beam CT using a C-arm system as front end and a spherical spiral as source trajectory [7258-14]Schomberg, H. / van de Haar, P. / Baaten, W. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Visibility of microcalcifications in CCD-based cone beam CT: a preliminary study [7258-21]Shen, Y. / Chen, L. / Ge, S. / Yi, Y. / Han, T. / Zhong, Y. / Lai, C.-J. / Liu, X. / Wang, T. / Shaw, C.C. et al. | 2009
-
Direct reconstruction of PET receptor binding parametric images using a simplified reference tissue model [7258-30]Wang, G. / Qi, J. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Multiple information tomosynthesis with grating-based phase contrast imaging [7258-58]Wang, Z. / Huang, Z. / Xiao, Y. / Zhang, L. / Kang, K. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Geometric calibration and distortion calibration for CT from scans of unknown objects using complementary rays [7258-61]Holt, K.M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Bronchial wall region extraction algorithm using multi-slice CT images [7258-90]Akashi, K. / Saita, S. / Kubo, M. / Kawata, Y. / Niki, N. / Nakano, Y. / Niimi, A. / Matsumoto, H. / Oguma, T. / Takiguchi, Y. et al. | 2009
-
Analytical scatter estimation for cone-beam computed tomography [7258-118]Ingleby, H.R. / Elbakri, I.A. / Rickey, D.W. / Pistorius, S. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Scatter correction algorithm without extra exposure for dual-energy digital mammography [7258-147]Chen, X. / Mou, X. / Yan, H. / Yu, H. / Zhang, L. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Fast kVp switching CT imaging of a dynamic cardiac phantom [7258-150]Pack, J.D. / Langan, D.A. / Wu, X. / Xu, D. / Benson, T.M. / Schmitz, A.M. / Tkaczyk, J.E. / Pavlicek, W. / Boltz, T.F. / Payden, R. et al. | 2009
-
MTF compensation for digital radiography system with indirect conversion flat panel detector [7258-189]Zhang, W. / Souchay, H. / Yang, C. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Dose reduction in digital breast tomosynthesis using a penalized maximum likelihood reconstruction [7258-193]Das, M. / Gifford, H. / O Connor, M. / Glick, S.J. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Spatio-temporal filtration of dynamic CT data using diffusion filters [7258-195]Bruder, H. / Raupach, R. / Klotz, E. / Stierstorfer, K. / Flohr, T. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Noise analysis in intensity-weighted region-of-interest imaging for cone-beam CT [7258-06]Cho, S. / Pearson, E. / Pelizzari, C.A. / Pan, X. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Joint image reconstruction and nonrigid motion estimation with a simple penalty that encourages local invertibility [7258-29]Chun, S.Y. / Fessler, J.A. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Quantification of three-dimensional tongue motion during speech using zHARP [7258-35]Liu, X. / Zhuo, J. / Agarwal, H. / Abd-Elmoniem, K.Z. / Murano, E. / Stone, M. / Gullapalli, R. / Prince, J.L. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Extension of DQE to include scatter, grid, magnification, and focal spot blur: a new experimental technique and metric [7258-45]Ranger, N.T. / Mackenzie, A. / Honey, I.D. / Dobbins, J.T. / Ravin, C.E. / Samei, E. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Feasibility of amorphous selenium based photon counting detectors for digital breast tomosynthesis [7258-51]Chen, J. / Lehnert, J. / O Connor, P. / De Geronimo, G. / Dolazza, E. / Tousignant, O. / Laperriere, L. / Greenspan, J. / Zhao, W. / SPIE (Society) et al. | 2009
-
A task-based evaluation method for x-ray breast imaging systems using variable-background phantoms [7258-56]Park, S. / Liu, H. / Jennings, R. / Leimbach, R. / Kyprianou, I. / Badano, A. / Myers, K. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Photon-counting CT with silicon detectors: feasibility for pediatric imaging [7258-76]Yveborg, M. / Xu, C. / Fredenberg, E. / Danielsson, M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Boundary reconstruction in limited-angle x-ray phase-contrast tomography [7258-78]Anastasio, M.A. / Sidky, E.Y. / Pan, X. / Chou, C.-Y. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Noise properties of iterative reconstruction techniques in low-dose CT scans [7258-80]Do, S. / Kalra, M.K. / Liang, Z. / Karl, W.C. / Brady, T.J. / Pien, H. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Digital breast tomosynthesis (DBT) versus full field digital mammography (FFDM): comparison of a system performance using a contrast detail phantom [7258-109]Nitrosi, A. / Borasi, G. / Bertolini, M. / Botti, A. / Tassoni, D. / Strocchi, S. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Measurement-based scatter correction for cone-beam CT in radiation therapy [7258-122]Zhu, L. / Xing, L. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Quasi-monochromatic x-ray filter with thin film multilayer for a large area radiation field [7258-130]Park, Y. / Han, S. / Chae, J. / Kim, C. / Chon, K.S. / Lee, H.-K. / Han, D.S. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Dual energy CT via fast kVp switching spectrum estimation [7258-140]Xu, D. / Langan, D.A. / Wu, X. / Pack, J.D. / Benson, T.M. / Tkaczky, J.E. / Schmitz, A.M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Impact of scattered radiation on spectral CT [7258-144]Wiegert, J. / Engel, K.J. / Herrmann, C. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Development of a high-speed CT imaging system using EMCCD camera [7258-153]Thacker, S.C. / Yang, K. / Packard, N. / Gaysinskiy, V. / Burkett, G. / Miller, S. / Boone, J.M. / Nagarkar, V. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Resolution improvement of the molecular imaging technique based on magnetic nanoparticles [7258-167]Ishihara, Y. / Kusayama, Y. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Breast tomosynthesis reconstruction with a multi-beam x-ray source [7258-197]Chen, Y. / Zhou, W. / Yang, G. / Qian, X. / Lu, J. / Zhou, O. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Enhancement of mobile C-arm cone-beam reconstruction using prior anatomical models [7258-199]Sadowsky, O. / Lee, J. / Sutter, E.G. / Wall, S.J. / Prince, J.L. / Taylor, R.H. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Local cone-beam SPECT reconstruction with non-uniform attenuation [7258-202]Chen, Y. / Wen, J. / Wang, L. / Liang, Z. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Configuration of automatic exposure control on mammography units for computed radiography to match patient dose of screen film systems [7258-216]Yang, C.-Y.J. / Huang, W. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Dose assessment of digital tomosynthesis in pediatric imaging [7258-219]Gislason, A. / Elbakri, I.A. / Reed, M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Simulation and analysis of image quality impact from single-source ultra-wide coverage CT scanner [7258-09]Li, B. / Toth, T.L. / Hsieh, J. / Tang, X. / Crandall, P. / Senzig, R.F. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Breast density measurement: 3D cone beam computed tomography (CBCT) images versus 2D digital mammograms [7258-20]Han, T. / Lai, C.-J. / Chen, L. / Liu, X. / Shen, Y. / Zhong, Y. / Ge, S. / Yi, Y. / Wang, T. / Yang, W.T. et al. | 2009
-
Blind motion compensation for positron-emission-tomography [7258-28]Blume, M. / Keil, A. / Navab, N. / Rafecas, M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Regularization of parallel MRI reconstruction using in vivo coil sensitivities [7258-34]Duan, Q. / Otazo, R. / Xu, J. / Sodickson, D.K. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
First physical measurements and clinical evaluation for long-view tomosynthesis [7258-55]Notohara, D. / Nishino, K. / Shibata, K. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
The impact of anisotropic sampling on the MTF reconstruction in limited aperture tomosynthesis [7258-60]Souchay, H. / Klausz, R. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Prior-image-based few-view cone beam CT for applications to daily scan in image-guided radiation therapy: preliminary study [7258-65]Cho, S. / Pearson, E. / Sidky, E.Y. / Bian, J. / Pelizzari, C.A. / Pan, X. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Perfusion from angiogram and a priori (PAP) with temporal regularization [7258-89]Taguchi, K. / Geschwind, J.-F.H. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Local correction of non-periodic motion in computed tomography [7258-93]Schretter, C. / Neukirchen, C. / Rose, G. / Bertram, M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Dual-energy contrast enhanced digital mammography: theoretical and experimental study of optimal monoenergetic beam parameters using synchrotron radiation [7258-141]Puong, S. / Iordache, R. / Bouchevreau, X. / Muller, S. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Advanced material separation technique based on dual energy CT scanning [7258-151]Zamyatin, A.A. / Natarajan, A. / Zou, Y. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Stationary micro-CT scanner using a distributed multi-beam field emission x-ray source: a feasibility study [7258-154]Peng, R. / Zhang, J. / Calderon-Colon, X. / Wang, S. / Sultana, S. / Chang, S. / Lu, J.P. / Zhou, O. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Method for optic nerve intensity characterization in mice from Mn^2^+ enhanced MR images [7258-168]Xiao, D. / Ribic, J. / Butzkueven, H. / Fang, K. / Kilpatrick, T.J. / Egan, G.F. / Salvado, O. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Tomographic mesh generation for OSEM reconstruction of SPECT images [7258-191]Lu, Y. / Yu, B. / Vogelsang, L. / Krol, A. / Xu, Y. / Hu, X. / Feiglin, D. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
X-ray tube-based diffraction enhanced imaging prototype images of full-thickness breast specimens: reader study evaluation [7258-210]Faulconer, L.S. / Parham, C. / Connor, D.J. / Koomen, M. / Kuzmiak, C. / Pavic, D. / Livasy, C.A. / Kim, E. / Zeng, D. / Cole, E.B. et al. | 2009
-
Digital radiography system using a new direct-detection flat panel detector and its system performance [7258-213]Park, J.-H. / Kang, W.-S. / Shin, B.-S. / Kang, H.-S. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Feasibility of using the micro CT imaging system as the conformal radiation therapy facility for small animals [7258-217]Tu, S.-J. / Hsieh, H.-L. / Chao, T.-C. / Lee, C.-C. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Investigation of the dosimetry of chest tomosynthesis [7258-223]Svalkvist, A. / Zachrisson, S. / Mansson, L.G. / Bath, M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Patient-specific dose estimation for pediatric abdomen-pelvis CT [7258-03]Li, X. / Samei, E. / Segars, W.P. / Sturgeon, G.M. / Colsher, J.G. / Frush, D.P. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Patient specific computerized phantoms to estimate dose in pediatric CT [7258-16]Segars, W.P. / Sturgeon, G. / Li, X. / Cheng, L. / Ceritoglu, C. / Ratnanather, J.T. / Miller, M.I. / Tsui, B.M.W. / Frush, D. / Samei, E. et al. | 2009
-
Novel insight into magnetic resonance through a spherical coordinate framework for the Bloch equation [7258-33]Tahayori, B. / Johnston, L.A. / Mareels, I.M.Y. / Farrell, P.M. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Simulating ultra-wideband imaging for the early detection of tissue injury [7258-38]Niu, W. / Hlavaty, K. / Tanska, D. / Tseng, N. / Li, J. / Penprase, B. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Evaluation of the x-ray response of amorphous selenium coated 100-μm pitch a-si active pixel sensors for tomosynthesis applications [7258-52]Taghibakhsh, F. / Hunter, D.M. / Karim, K.S. / Belev, G. / Kasap, S.O. / Verpakhovski, V. / Yaffe, M.J. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Cardiac imaging with multi-sector data acquisition in volumetric CT: variation of effective temporal resolution and its potential clinical consequences [7258-110]Tang, X. / Hsieh, J. / Taha, B.H. / Vass, M.L. / Seamans, J.L. / Okerlund, D.R. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Diagnostic quality of time-averaged ECG-gated CT data [7258-114]Klein, A. / Oostveen, L.J. / Greuter, M.J.W. / Hoogeveen, Y. / Schultze, L.J. / Slump, C.H. / Renema, W.K.J. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Three-dimensional metal artifact reduction method for dental conebeam CT scanners [7258-123]Kobayashi, K. / Katsumata, A. / Ito, K. / Aoki, T. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
A material decomposition method for dual energy micro-CT [7258-148]Johnston, S.M. / Johnson, G.A. / Badea, C.T. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Liquid lens confocal microscopy with advanced signal processing for higher resolution 3D imaging [7258-155]Riza, N.A. / Sheikh, M.A. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Image quality and signal distribution in 1.5-T and 3-T MRI in mild traumatic brain injury patients [7258-171]Rossi, M. / Dastidar, P. / Ryymin, P. / Ylinen, A. / Ohman, J. / Soimakallio, S. / Eskola, H. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009
-
Optical coherence tomography and confocal microscopy investigations of dental structures and restoration materials [7258-172]Negrutiu, M.L. / Sinescu, C. / Rominu, M. / Hughes, M. / Dobre, G. / Podoleanu, A.G. / SPIE (Society) / American Association of Physicists in Medicine et al. | 2009