Please choose your delivery country and your customer group
Considered is the operation of supply system of a single-phase machine for resistance spot welding (RSW) with introducing of scheme of longitudinal compensation of reactive power into the primary circuit of welding transformer. Machines for RSW are characterized by a high consumed power, the significant part of which is a reactive component. This leads to increase in general installed power of working regions and asymmetry of loading phases of supply distribution three-phase mains. It is shown in the work that system with a longitudinal compensator is well interacted with a standard thyristor controller of power of machine and allows keeping a high value of power factor within the range of phase control up to 60. The application of longitudinal compensation gives technological advantages of spot welding, as the power factor of machine with a compensator depends little on the resistance of welding contact. Therefore the welding of metals in the wide range of specific resistances is possible: from low-carbon steels up to some light alloys and metals with protective coatings. Low cost of additional equipping of existing machines with longitudinal compensator with a simultaneous improvement of their technological properties makes the method of longitudinal compensation challenging for industrial application.