Dielectric properties of epoxy resins with oxide nanofillers and their accelerated ageing (English)
- New search for: Klampar, Marian
- New search for: Spohner, Milan
- New search for: Skarvada, Pavel
- New search for: Dallaeva, Dinara
- New search for: Kobrtck, Jozef
- New search for: Liedermann, Karel
- New search for: Klampar, Marian
- New search for: Spohner, Milan
- New search for: Skarvada, Pavel
- New search for: Dallaeva, Dinara
- New search for: Kobrtck, Jozef
- New search for: Liedermann, Karel
In:
2013 IEEE Electrical Insulation Conference (EIC)
;
286-290
;
2013
- Conference paper / Electronic Resource
-
Title:Dielectric properties of epoxy resins with oxide nanofillers and their accelerated ageing
-
Contributors:Klampar, Marian ( author ) / Spohner, Milan ( author ) / Skarvada, Pavel ( author ) / Dallaeva, Dinara ( author ) / Kobrtck, Jozef ( author ) / Liedermann, Karel ( author )
-
Published in:
-
Publisher:
- New search for: IEEE
-
Publication date:2013-06-01
-
Size:2533492 byte
-
ISBN:
-
DOI:
-
Type of media:Conference paper
-
Type of material:Electronic Resource
-
Language:English
-
Source:
Table of contents conference proceedings
The tables of contents are generated automatically and are based on the data records of the individual contributions available in the index of the TIB portal. The display of the Tables of Contents may therefore be incomplete.
- 1
-
End-winding vibration monitoring: Pivotal in preventing major damage on a large turbo-generatorTetreault, Andre / Zhengping, Zhou et al. | 2013
- 1
-
to: To: Attendees of the 31st Electrical Insulation Conference [Welcome message]David, Eric et al. | 2013
- 1
-
Table of contents| 2013
- 1
-
Board of Governors| 2013
- 1
-
To: Attendees of the 31st Electrical Insulation Conference [welcome message]Stone, Greg et al. | 2013
- 1
-
Author index| 2013
- 1
-
2013 John Tanaka Distinguished Leadership Award| 2013
- 1
-
Electrical Insulation Conference: Past General Conference Chairs| 2013
- 7
-
Experience with DC polarization-depolarization measurements on stator winding insulationStone, G. C. / Sasic, M. et al. | 2013
- 11
-
Adapting the FBG cavity sensor structure to monitor and diagnose PD and vibration sparking in large generatorKung, Peter / Wang, Lutang / Pan, Sylvia / Comanici, Maria Iulia et al. | 2013
- 16
-
Modelling of the transient transport of electrons in dielectrics for one-carrier pulsed injectionMeftali, N. / Bouazabia, S. et al. | 2013
- 20
-
Epoxy composites with glass bubbles for electrical applicationChen, Jiansheng / Meng, Delun / Feng, Yong / Li, Nan / Krivda, Andrej / Greuter, Felix / Rocks, Jens et al. | 2013
- 25
-
Dielectric properties of epoxy/BN micro- and meso-composites: Dielectric response at low and high electrical field strengthsHeid, T. F. / Freebody, N. / Frechette, M. F. / Couderc, H. / Vanga, C. / David, E. / Vaughan, A. S. et al. | 2013
- 30
-
Construction of finite impulse wavelet filter for partial discharge localisation inside a transformer windingAbd Rahman, M. S. / Rapisarda, P. / Lewin, P. L. et al. | 2013
- 35
-
Investigation of complex, in-homogenous insulation system with multiple time constant by recovery voltage measurement (RVM)Voros, Csaba / Csepes, Gusztav / Nemeth, Balint / Berta, Istvan et al. | 2013
- 40
-
Influence of temperature on frequency response analysis of transformer windingBagheri, Mehdi / Phung, B. T. / Blackburn, Trevor / Naderian, Ali et al. | 2013
- 45
-
Life curves for new and thermally aged oil-impregnated paper insulationChmura, Lukasz / Boorn, D. V. D. / Morshuis, P. H. F. / Smit, J. J. et al. | 2013
- 49
-
Influence of water content on the electrical properties of insulating vegetable oil-based nanofluidsDu, Bin / Li, Jian / Wang, Baimei / Xiang, Junru / Zhang, Zhaotao et al. | 2013
- 52
-
Modelling of partial discharge pulses in high voltage cable insulation using finite element analysis softwareIllias, H. A. / Yon, H. R. / Bakar, A. H. A. / Mokhlis, H. / Chen, G. / Lewin, P. L. / Ariffin, A. M. et al. | 2013
- 57
-
Power cable modeling for PD pulse propagation and sensitivityWild, M. / Tenbohlen, S. / Gulski, E. / Jongen, R. et al. | 2013
- 61
-
Options for cables post diagnostic testingChatterton, Wayne J. / Derezes, J. Gus et al. | 2013
- 66
-
Feasibility of reduced insulation thickness in medium voltage power cable designsHyvonen, Petri / Kluss, Joni / Saarijarvi, Eero / Millar, John et al. | 2013
- 77
-
Computation of tower surge impedance in transmission lineCao, Truong X. / Pham, Thinh / Boggs, Steven et al. | 2013
- 81
-
Electromagnetic transient simulation of lightning overvoltage in a wind farmNguyen, Thuan Q. / Pham, Thinh / Tran, Top V. et al. | 2013
- 85
-
Comparison of heat transfer in air and SF6 in high voltage GISNovak, Balazs et al. | 2013
- 90
-
A transient model of lightning breakdown process based on photographic measurementsShirvani, Ali / Malekian, Kaveh / Schufft, Wolfgang et al. | 2013
- 100
-
Extra low frequency electric and magnetic fields during live-line maintenanceGocsei, Gabor / Nemeth, Balint / Tarcsa, Daniel et al. | 2013
- 110
-
Influence of triple-junction on sparkover voltage for a series gap of arresterTokunaga, Tatsuya / Nishikawa, Shinnosuke / Sakoda, Tatsuya / Fukano, Takato et al. | 2013
- 114
-
Comparison between 2D and 3D modeling of an EHV post station insulator equipped with a grading ringVolat, C. / Ezzaidi, H. / Fofana, I. et al. | 2013
- 119
-
Acoustic noise evaluation for overhead line conductorsLi, Q. / Shuttleworth, R. / Zhang, G. / Dupere, I. / Rowland, S. M. et al. | 2013
- 124
-
Estimation of partial discharge inception voltages due to voids in solid sheet insulationZuberi, M. U. / Masood, A. / Husain, E. / Anwar, A. et al. | 2013
- 129
-
The effectiveness assessment of calibration and measurement of PD apparent charge quantityLiu, Hongjing / Jin, Wenjie / Liu, Jianyin / Zheng, Zhong / Cheng, Yangchun / Huang, Zhiwei / Feng, Wei / Chen, Xiaoyun et al. | 2013
- 138
-
Partial discharge characteristics of NYCY low-voltage cablesCselko, Richard / Garcia, Mario Macos / Berta, Istvan et al. | 2013
- 142
-
Location of partial discharge occurring in ground coil of superconducting Maglev system under noise environment using radio interferometer systemKawada, Masatake / Suzuki, Masao / Ikeda, Ryohei et al. | 2013
- 147
-
The influence of external magnetic fields on the partial discharge characteristics of voidsReid, A. J. / Hepbum, D. M. / Stewart, B. G. et al. | 2013
- 159
-
Reliability estimation for populations with limited and heavily censored failure informationChmura, Lukasz / Morshuis, P. H. F. / Gulski, E. / Smit, J. J. / Janssen, Anton et al. | 2013
- 168
-
A comparative analysis of performance of well-known methods for conforming distribution of impulsive voltage along regulating windingde Lima, Paulo A. P. / Cabral, Sergio H. L. et al. | 2013
- 173
-
Validation of the forensic analysis applied to distribution transformers (FAADT)Ferreira, D. A. P. / Nakagawa, F. / Altafim, R. A. C. / da Silva, J. F. R. / Altafim, R. A. P. et al. | 2013
- 178
-
Health index: The TERNA's practical approach for transformers fleet managementScatiggio, Fabio / Pompili, Massimo et al. | 2013
- 183
-
Effect of electrical and thermo-mechanical stresses on the surge capability of MV form-wound AC stator coilsOmranipour, Ramtin / Haq, Saeed Ul et al. | 2013
- 187
-
Analysis of times-to-failure of various turn insulations of form-wound coils under PWM voltage waveformMoonesan, Mohammad Saleh / Jayaram, Shesha / Cherney, Edward / Omranipour, Ramtin / Haq, Saeed Ul et al. | 2013
- 191
-
Determination of stator temperature profile using distributed sensingHudon, C / Levesque, M / Zou, L / Picard, J. et al. | 2013
- 196
-
Mica tape and VPI resin insulation system options for medium voltage applicationsFrost, Nancy / Winkeler, Mark / Tuckwell, Steve et al. | 2013
- 201
-
An optimal surge arrester for EHV air insulated stations utilizing high-gradient MO resistorsStenstrom, L. / Taylor, J. / Westerlund, H. et al. | 2013
- 206
-
Automatic inspection of outdoor insulators using image processing and intelligent techniquesKhalayli, Loai / Sagban, Hamid Al / Shoman, Hossam / Assaleh, Khaled / Ei-Hag, Ayman et al. | 2013
- 210
-
Electric field analysis of 132kv EPDM insulator and correlation with ageing featuresTzimas, Antonios / Zachariades, Christos / Rowland, Simon M. et al. | 2013
- 215
-
Measurement system for very fast transient overvoltages in gas insulated switchgearBurow, S. / Kohler, W. / Tenbohlen, S. / Straumann, U. et al. | 2013
- 220
-
Experience with frequency response analysis (FRA) for the mechanical condition assessment of transformer windingsPicher, Patrick / Rajotte, Claude / Tardif, Carl et al. | 2013
- 225
-
Shunt capacitance influences on single-phase transformer FRA spectrumBagheri, Mehdi / Phung, B.T. / Blackburn, Trevor / Naderian, Ali et al. | 2013
- 230
-
Continuous monitoring of power transformer solid insulation dry-out process — Application of dielectric frequency responseRobalino, Diego M. / Werelius, Peter et al. | 2013
- 235
-
Effects of voltages with high-frequency contents on the transformer insulation propertiesKhanali, Mahdi / Jayaram, Shesha / Cheng, John et al. | 2013
- 239
-
Pole mounted distribution transformers insulation condition assessmentNoirhomme, B. / Jalbert, J. / Lessard, M.-C. / Brochu, F. / Hachichi, S. et al. | 2013
- 244
-
Magnetic wedge failures in wind turbine generatorsAlewine, Kevin / Wilson, Chuck et al. | 2013
- 248
-
Thermal and thermo-mechanical aging of epoxy-mica insulated stator barsProvencher, H. / Hudon, C. / David, E. et al. | 2013
- 253
-
Insulation performance evaluation of high temperature wire candidates for aerospace electrical machine winding applicationFang, L. / Cotton, I. / Wang, Z. J. / Freer, R. et al. | 2013
- 257
-
Motor & generator high voltage AC testing over voltage coil testing: Withstand & qualitative diagnostics exploredPeschel, Michael T. et al. | 2013
- 263
-
Tailoring of the electrical properties of silicon carbide for field grading applicationVanga-Bouanga, C. / Reid, T. F. / David, E. / Frechette, M. F. / Savoie, S. et al. | 2013
- 267
-
Evaluation of partial discharge resistance of polypropylene with clay nanocompositesPoda, Anil B. / Basappa, Prathap et al. | 2013
- 272
-
Effect of filler concentration on dielectric properties of RTV silicone rubber/TiO2 nanocompositeMadidi, F. / Momen, G. / Farzaneh, M. et al. | 2013
- 276
-
Dielectric response of polyethylene modified with nanosilicaFrechette, Michel F. / Guo, M. / Heid, Th. / David, E. / Savoie, S. / Sutton, S. / Han, Suh J. et al. | 2013
- 281
-
Analyses of surface degradation of nano-filled polypropylene films through partial discharges & surface studyPoda, Anil B. / Basappa, Prathap / Fritzel, Christopher S. et al. | 2013
- 286
-
Dielectric properties of epoxy resins with oxide nanofillers and their accelerated ageingKlampar, Marian / Spohner, Milan / Skarvada, Pavel / Dallaeva, Dinara / Kobrtck, Jozef / Liedermann, Karel et al. | 2013
- 291
-
Dielectric properties of PA6 — Montmorillonite nanocomposites under moderate electric fieldCouderc, H. / David, E. / Frechette, M. / Savoie, S. et al. | 2013
- 295
-
The influence of corona near to the bushing of a transformer on partial discharge measurement with an acoustic emission sensorMahmood Najafi, Seyed Amir / Peimankar, Abdolrahman / Saadati, Hassan / Gockenbach, Ernst / Borsi, Hossein et al. | 2013
- 299
-
Electric stress grading on bushings of combined instrument transformers using high permittivity polymeric compositesParedes-Olguin, M. / Gomez-Yanez, C. / Espino-Cortes, F. P. / Ramirez, E. et al. | 2013
- 304
-
Experiences in testing of AC and DC bushingsLick, W. et al. | 2013
- 308
-
The gassing tendency of oil under corona dischargeGhalkhani, M. / Fofana, I. / Hemmatjou, H. et al. | 2013
- 313
-
Electrical conductivity measurement and determination of ion mobility in insulating oilVahidi, Farzaneh / Jovalekic, Mark / Tenbohlen, Stefan / Rosner, Michael / Perrier, Christophe / Fink, Harald et al. | 2013
- 318
-
Adapting the FBG cavity sensor structure to monitor and diagnose PD in large power transformerKung, Peter / Wang, Lutang / Pan, Sylvia / Comanici, Maria Iulia et al. | 2013
- 323
-
Partial discharge testing on air-cooled generators in marine environmentsWarren, Vicki et al. | 2013
- 329
-
Using non-intrusive sensors to detect partial discharges in a PWM inverter environment: A twisted pair exampleBillard, Thibaut / Fresnet, Francois / Makarov, Maxirne / Lebey, Thierry / Castelan, Philippe / Bidan, Pierre / Dinculescu, Sorin et al. | 2013
- 333
-
Identification of PD defect typologies using a support vector machineLewin, P. L. / Hunter, J. A. / Hao, L. / Contin, A. et al. | 2013
- 337
-
Theoretical consideration and numerical simulation regarding TDR on rotor windingsStaubach, Christian / Merte, Ralf / Kokoschka, Daniel et al. | 2013
- 342
-
Inspection of ground-wall insulation for AC rotating machines using X-ray tomographyContin, A. / Schena, G. / Stanic, G. L. / Peruzzi, G. et al. | 2013
- 346
-
Numerical analysis of the combined effects of booster sheds and grading rings on an ice-covered EHV ceramic post insulatorAle-Emran, S. M. / Farzaneh, M. et al. | 2013
- 351
-
Spatial-temporal investigation of breakdown of long air gaps by lightning voltages up to 2.4 MVShirvani, Ali / Schufft, Wolfgang / Pampel, Hans-Peter / Schmidt, Uwe et al. | 2013
- 356
-
Comparative inclined plane tests on silicone and EPDM elastomers under DCGhunem, Refat Atef / Jayaram, Shesha H. / Cherney, Edward A. et al. | 2013
- 360
-
A new single-arc AC dynamic FEM model of arc propagation on ice surfacesJabbari, M. / Volat, C. / Farzaneh, M. et al. | 2013
- 365
-
Contactless optical sensors for in situ AC and DC electric field measurement and diagnosticsVolat, Christophe / Duvillaret, Lionel / Lecoche, Frederic / Dahdah, Jean / Gaborit, Gwenael et al. | 2013
- 370
-
Optimization of corona ring design for a 400KV non-ceramic insulatorMurawwi, Esam Al / Mohammed, Alip / Alip, Zapaer / Ei-Hag, Ayman et al. | 2013
- 374
-
Low viscosity insulating liquid based on natural esters for distribution transformersBertrand, Yves / Lauzevis, Patrick et al. | 2013
- 378
-
The electrostatic charging tendency of some environmentally friendly insulating fluidsTalhi, M. / Fofana, I. / Fiazi, S. et al. | 2013
- 383
-
Electrical properties of natural oils and methyl esters of their constitutive fatty acidsSpohner, Milan / Klampar, Marian / Liedermann, Karel et al. | 2013
- 387
-
Methanol marker for the thermal performance qualification of power transformersRyadi, Mohamed / Tanguy, Alain / Jalbert, Jocelyn et al. | 2013
- 392
-
Influence of transformer oil acidity on insulating paper degradationNoirhomme, B. / Lessard, M.-C. / Jalbert, J. / Besner, S. / Brochu, F. / Dupuis, E. et al. | 2013
- 397
-
Real-time monitoring of leakage current on insulating cross-arms in relation to local weather conditionsZachariades, C. / Rowland, S. M. / Cotton, I. et al. | 2013
- 402
-
Experience with electrical testing of aerial devices for use at 69–500 kvMcDermid, W. et al. | 2013
- 404
-
Electrical degradation of 15 kv composite insulator under accelerated aging conditionsTripathi, Rahul / Grzybowski, G. / Ward, R. et al. | 2013
- 409
-
Comparison between the use of surface and volume conductivity to compute potential distribution along an insulator in presence of a thin conductive layerVolat, C. et al. | 2013
- 414
-
Equivalent surface conductivity of an ice-covered insulator during DC flashoverTaheri, S. / Farzaneh, M. / Fofana, I. et al. | 2013
- 419
-
Evaluation of CFO for medium voltage insulators submitted to non-standard impulse shapes experimental resultsLopes, G. P. / Pedroso, J. A. D. / Martinez, M. L. B. et al. | 2013
- 424
-
Dielectric performance of nanocomposites synthesized by poly(ethylene oxide)-like film coated silica nanoparticles by plasma polymerizationYan, Wei / Phung, B. T. / Han, Zhao Jun / Ken Ostrikov, Kostya et al. | 2013
- 429
-
Electrical testing of high voltage insulators reinforced with nano particles and its fractal analysisRamirez-Vazquez, Isaias / Salgado-Talavera, Javier Eduardo / Ruiz-Pinales, Jose et al. | 2013
- 434
-
Comparison of standards requirements for clearances in aerospacePeesapati, V. / Fang, L. / Giussani, R. / Cotton, I. et al. | 2013
- 439
-
Damping of VFTO by RF resonator and nanocrystalline materialsBurow, S. / Kohler, W. / Tenbohlen, S. / Straumann, U. et al. | 2013
- 444
-
Characterization of UHMWPE/POSS composite prepared by ball millingGuo, M. / Frechette, M. F. / David, E. / Couderc, H. / Savoie, S. / Vanga Bouanga, C. / Demarquette, N. R. et al. | 2013
- 449
-
Identification of overheating in transformer solid insulation by polarization depolarization current analysisBhumiwat, S. A. et al. | 2013
- 459
-
Impact of corrosive sulfur in transformer insulation paperAmaro, P. S. / Holt, A. F. / Facciotti, M. / Pilgrim, J. A. / Lewin, P. L. / Brown, R. C. D. / Wilson, G. / Jarman, P. N. et al. | 2013
- 464
-
Ageing diagnosis of MV/LV distribution transformers via chemical indicators in oilLaurichesse, Delphine / Bertrand, Yves / Tran-Duy, Chau / Murin, Valerie et al. | 2013
- 469
-
An initial study into silver corrosion in transformers following oil reclamationHolt, A. F. / Facciotti, M. / Amaro, P. / Brown, R. C. D. / Lewin, P. L. / Pilgrim, J. A. / Wilson, G. / Jarman, P. et al. | 2013
- 473
-
Development of a generator prognostic toolAmyot, N. / Hudon, C. / Levesque, M. / Belec, M. / Brabant, F. / St-Louis, C. et al. | 2013
- 477
-
Consequences of protection and control deficienciesMcDermid, W. / Solomon, B. G. et al. | 2013
- 479
-
Insulation degradation analysis of stator bars subjected to slot partial dischargesLevesque, M. / Hudon, C. / David, E. et al. | 2013
- 484
-
Forensic analysis of multiple medium voltage 3MW self-excited generators following field testingPenrose, Howard W et al. | 2013
- 487
-
Simulating insulation discharge processes in the laboratoryMcKinnon, David L. / Penrose, Howard W / Frost, Nancy et al. | 2013
- 490
-
Incapability of analog relay protection to detect generator stator winding ground failures at neutral endMaughan, Clyde V. et al. | 2013
- 494
-
Water treeing in XLPE insulation at a combined DC and high frequency AC stressSaeternes, Hans H. / Aakervik, Jorund / Hvidsten, Sverre et al. | 2013
- 499
-
Practical aspects of PD localization for long length power cablesWild, M. / Tenbohlen, S. / Gulski, E. / Jongen, R. / de Vries, F. et al. | 2013
- 504
-
Electrical condition monitoring techniques for low-voltage cables used in nuclear power plantsVerardi, L. / Fabiani, D. / Montanari, G. C. / Zak, Pavel et al. | 2013
- 509
-
Water treeing in subsea XLPE cables with thermal gradientHelleso, Svein Magne / Hvidsten, Sverre / Furuheim, Knut Magne / Hakonseth, Gunnar et al. | 2013
- 513
-
Current rating methodology for mass impregnated HVDC cablesHuang, Z. Y. / Pilgrim, J. A. / Lewin, P. L. / Swingler, S. G. / Payne, D. et al. | 2013
- 518
-
DC utilization of existing LVAC distribution cablesAntoniou, D. / Tzimas, A. / Rowland, S. M. et al. | 2013
- 523
-
PD test procedure as after laying acceptance test on HV and EHV polymeric cable systemsFornasari, L. / Montanari, G. C. / Cavallini, A. et al. | 2013