A medical simulator for subcutaneous contraceptive implant insertion (English)
- New search for: Jardin, A.
- New search for: Jardin, A.
- New search for: Pham, M.T.
- New search for: Mallet, A.
- New search for: Redarce, T.
- New search for: Dupuis, O.
In:
Medical engineering & physics
;
30
, 9
; 1134-1142
;
2008
-
ISSN:
- Article (Journal) / Print
-
Title:A medical simulator for subcutaneous contraceptive implant insertion
-
Contributors:
-
Published in:Medical engineering & physics ; 30, 9 ; 1134-1142
-
Publisher:
- New search for: Elsevier Science
-
Place of publication:Amsterdam [u.a.]
-
Publication date:2008
-
ISSN:
-
ZDBID:
-
Type of media:Article (Journal)
-
Type of material:Print
-
Language:English
- New search for: 275/4212
- New search for: 44.09
- Further information on Basic classification
-
Keywords:
-
Classification:
-
Source:
Table of contents – Volume 30, Issue 9
The tables of contents are generated automatically and are based on the data records of the individual contributions available in the index of the TIB portal. The display of the Tables of Contents may therefore be incomplete.
- 1089
-
A finite element model to accurately predict real deformations of the breastdel Palomar, A. Pérez / Calvo, B. / Herrero, J. / López, J. / Doblaré, M. et al. | 2008
- 1098
-
Correlation between compression, tensile and tearing tests on healthy and calcified aortic tissuesWalraevens, Joris / Willaert, Bert / De Win, Gunter / Ranftl, Andrea / De Schutter, Joris / Sloten, Jos Vander et al. | 2008
- 1105
-
Predicting termination of atrial fibrillation based on the structure and quantification of the recurrence plotSun, Rongrong / Wang, Yuanyuan et al. | 2008
- 1112
-
Effect of ovariectomy on BMD, micro-architecture and biomechanics of cortical and cancellous bones in a sheep modelWu, Zi-xiang / Lei, Wei / Hu, Yun-yu / Wang, Hai-qiang / Wan, Shi-yong / Ma, Zhen-sheng / Sang, Hong-xun / Fu, Suo-chao / Han, Yi-sheng et al. | 2008
- 1119
-
Correction of acetabular cup orientation measurements for X-ray beam offsetDerbyshire, Brian et al. | 2008
- 1127
-
Cervical spine biomechanics following implantation of a disc prosthesisGalbusera, Fabio / Bellini, Chiara M. / Raimondi, Manuela T. / Fornari, Maurizio / Assietti, Roberto et al. | 2008
- 1134
-
A medical simulator for subcutaneous contraceptive implant insertionJardin, A. / Pham, M.T. / Mallet, A. / Redarce, T. / Dupuis, O. et al. | 2008
- 1143
-
Spectroscopic investigations of carious tooth decayThareja, R.K. / Sharma, A.K. / Shukla, Shobha et al. | 2008
- 1149
-
Pressure pulsation in roller pumps: A validated lumped parameter modelMoscato, Francesco / Colacino, Francesco M. / Arabia, Maurizio / Danieli, Guido A. et al. | 2008
- 1159
-
Validity of the local nonlinear arterial flow theory: Influence of the upstream and downstream conditionsBensalah, A. / Flaud, P. et al. | 2008
- 1168
-
The effect of the subcutaneous fat on the transfer of current through skin and into musclePetrofsky, Jerrold et al. | 2008
- 1177
-
Topology optimization of a novel stent platform with drug reservoirsWu, Wei / Yang, Da-Zhi / Huang, Ying-Ying / Qi, Min / Wang, Wei-Qiang et al. | 2008
- 1186
-
Development of a new design of hip protectors using finite element analysis and mechanical testsSchmid Daners, Marianne / Wullschleger, Luc / Derler, Siegfried / Schmitt, Kai-Uwe et al. | 2008
- 1193
-
3D flow study in a mildly stenotic coronary artery phantom using a whole volume PIV methodBrunette, J. / Mongrain, R. / Laurier, J. / Galaz, R. / Tardif, J.C. et al. | 2008
- 1201
-
Risk analysis and implantsBraceras, I. / Ipiñazar, E. / De Maeztu, M.A. / Alava, J.I. et al. | 2008
- 1205
-
Erratum to “The identification of vertical velocity profiles using an inertial sensor to investigate pre-impact detection of falls” [Med. Eng. Phys. 30 (2008) 937–946]Bourke, A.K. / O’Donovan, K.J. / ÓLaighin, G. et al. | 2008
- CO2
-