Experimental Analysis of Thermal Conductivity for Building Materials Depending on Moisture Content (English)
- New search for: Dell’Isola, M.
- New search for: d’Ambrosio Alfano, F. R.
- New search for: Giovinco, G.
- New search for: Ianniello, E.
- New search for: Dell’Isola, M.
- New search for: d’Ambrosio Alfano, F. R.
- New search for: Giovinco, G.
- New search for: Ianniello, E.
In:
International Journal of Thermophysics
;
33
, 8-9
; 1674-1685
;
2012
-
ISSN:
- Article (Journal) / Print
-
Title:Experimental Analysis of Thermal Conductivity for Building Materials Depending on Moisture Content
-
Contributors:Dell’Isola, M. ( author ) / d’Ambrosio Alfano, F. R. ( author ) / Giovinco, G. ( author ) / Ianniello, E. ( author )
-
Published in:International Journal of Thermophysics ; 33, 8-9 ; 1674-1685
-
Publisher:
- New search for: Springer US
- New search for: Springer
-
Place of publication:Dordrecht
-
Publication date:2012
-
ISSN:
-
ZDBID:
-
DOI:
-
Type of media:Article (Journal)
-
Type of material:Print
-
Language:English
- New search for: 33.00
- Further information on Basic classification
- New search for: 770/3430
-
Keywords:
-
Classification:
-
Source:
Table of contents – Volume 33, Issue 8-9
The tables of contents are generated automatically and are based on the data records of the individual contributions available in the index of the TIB portal. The display of the Tables of Contents may therefore be incomplete.
- 1335
-
TEOS-10: A New International Oceanographic Standard for Seawater, Ice, Fluid Water, and Humid AirFeistel, R. et al. | 2010
- 1352
-
Microwave Determination of Water Mole Fraction in Humid Gas MixturesCuccaro, R. / Gavioso, R. M. / Benedetto, G. / Madonna Ripa, D. / Fernicola, V. / Guianvarc’h, C. et al. | 2011
- 1363
-
Investigation of the Ice–Water Vapor Equilibrium Along the Sublimation LineFernicola, V. / Rosso, L. / Giovannini, M. et al. | 2011
- 1374
-
On the Way to Determination of the Vapor-Pressure Curve of Pure WaterMokdad, S. / Georgin, E. / Mokbel, I. / Jose, J. / Hermier, Y. / Himbert, M. et al. | 2012
- 1390
-
Modification of Vapor-Pressure Reference Functions to Include Parameter CovarianceLovell-Smith, J. et al. | 2012
- 1408
-
Practical Study of Psychrometer CalibrationsKentved, Anders Bonde / Heinonen, Martti / Hudoklin, Domen et al. | 2012
- 1422
-
Investigation of the Equivalence of National Dew-Point Temperature Realizations in the −50 °C to + 20 °C RangeHeinonen, Martti / Anagnostou, Miltiadis / Bell, Stephanie / Stevens, Mark / Benyon, Robert / Bergerud, Reidun Anita / Bojkovski, Jovan / Bosma, Rien / Nielsen, Jan / Böse, Norbert et al. | 2011
- 1438
-
Comparative Study of Humidity Analyzers in Nitrogen Below 1 μ mol/molBenyon, R. / Hernández, P. et al. | 2012
- 1451
-
Intercomparison of the Dew-Point Temperature Realizations at LPM and MIKES in the Range from −70 °C to + 20 ° CHeinonen, Martti / Zvizdic, Davor / Sestan, Danijel et al. | 2011
- 1458
-
Bilateral Comparison of Relative Humidity Standards Between NMISA and MIKESJonker, D. / Heinonen, M. / Liedberg, H. G. / Mnguni, M. R. et al. | 2012
- 1468
-
Comparison of Meteorological Service Calibration Laboratories in Southeastern EuropeGroselj, D. / Bojkovski, J. et al. | 2012
- 1477
-
A Humidity Generator for Temperatures up to 200 °C and Pressures up to 1.6 MPaVega-Maza, D. / Miller, W. W. / Ripple, D. C. / Scace, G. E. et al. | 2010
- 1488
-
Uncertainty Budget for the NIST Hybrid Humidity GeneratorMeyer, C. W. / Miller, W. W. / Ripple, D. C. / Scace, G. E. et al. | 2010
- 1500
-
Novel Flow Measurement/Control System in Magnetic Suspension Balance/Diffusion-Tube Humidity GeneratorAbe, H. et al. | 2011
- 1511
-
Development of a Dew-Point Generator for Gases Other than Air and Nitrogen and Pressures up to 6 MPaBosma, R. / Peruzzi, A. et al. | 2012
- 1520
-
A New Attempt on a Coulometric Trace Humidity GeneratorMackrodt, P. et al. | 2012
- 1536
-
New Primary Dew-Point Generators at HMI/FSB-LPM in the Range from −70 °C to +60 °CZvizdic, Davor / Heinonen, Martti / Sestan, Danijel et al. | 2012
- 1550
-
Consistency of the National Realization of Dew-Point Temperature Using Standard Humidity GeneratorsBenyon, R. / Vicente, T. et al. | 2012
- 1559
-
Uncertainty of the Kriss Low Frost-Point Humidity GeneratorChoi, B. I. / Kim, J. C. / Woo, S. B. et al. | 2012
- 1568
-
Measurement Uncertainty of Dew-Point Temperature in a Two-Pressure Humidity GeneratorMartins, L. Lages / Ribeiro, A. Silva / Alves e Sousa, J. / Forbes, Alistair B. et al. | 2011
- 1583
-
Humidity, Pressure, and Temperature Measurements in an Interdigitated-Flow PEM Hydrogen Fuel CellBell, S. / Hinds, G. / de Podesta, M. / Stevens, M. / Wilkinson, J. et al. | 2011
- 1595
-
Uncertainty Evaluation of the New Setup for Measurement of Water-Vapor Permeation Rate by a Dew-Point SensorHudoklin, D. / Šetina, J. / Drnovšek, J. et al. | 2012
- 1606
-
Artificial Fruit: Postharvest Online Monitoring of Agricultural Food by Measuring Humidity and TemperatureHübert, T. / Lang, C. et al. | 2011
- 1616
-
Influence of Measurement Uncertainties on the Thermal Environment AssessmentDell’Isola, M. / Frattolillo, A. / Palella, B. I. / Riccio, G. et al. | 2012
- 1633
-
Traceability and Online Publication of Weather Station Measurements of Temperature, Pressure, and HumidityLopardo, G. / Marengo, D. / Meda, A. / Merlone, A. / Moro, F. / Pennecchi, F. R. / Sardi, M. et al. | 2012
- 1642
-
Extremely Fast 1 μmol · $ mol^{−1} $ Water-Vapor Measurement by a 1 mm Diameter Spherical SAW DeviceTakeda, N. / Motozawa, M. et al. | 2012
- 1650
-
Non-destructive Moisture Content Measurement of Bioabsorbable Polymers Used in Medical ImplantsCarroll, P. A. / Bell, S. A. / Maxwell, A. S. / Tomlins, P. E. et al. | 2011
- 1661
-
Application of Time-Domain Reflectometry for Measurement of Moisture Profiles in a Drying ExperimentPavlík, Z. / Mihulka, J. / Fiala, L. / Černý, R. et al. | 2011
- 1674
-
Experimental Analysis of Thermal Conductivity for Building Materials Depending on Moisture ContentDell’Isola, M. / d’Ambrosio Alfano, F. R. / Giovinco, G. / Ianniello, E. et al. | 2012
- 1686
-
Thermal Conductivity of Humid AirBeirão, S.G.S. / Ribeiro, A.P.C. / Lourenço, M.J.V. / Santos, F.J.V. / Nieto de Castro, C.A. et al. | 2012
- 1704
-
Determination of Moisture Diffusivity as a Function of Both Moisture and TemperaturePavlík, Z. / Černý, R. et al. | 2011
- 1715
-
The Effect of Pressure on Moisture Diffusion in Polymer Matrix CompositesPilli, S. P. / Smith, L. V. et al. | 2012
- 1726
-
Pressure-Drop Considerations in the Characterization of Dew-Point Transfer Standards at High TemperaturesMitter, H. / Böse, N. / Benyon, R. / Vicente, T. et al. | 2012
- 1741
-
An Investigation of the Relation Between Contact Thermometry and Dew-Point Temperature RealizationBenyon, R. / Böse, N. / Mitter, H. / Mutter, D. / Vicente, T. et al. | 2012
- 1758
-
Evaluation of the Long-Term Stability and Temperature Coefficient of Dew-Point HygrometersBenyon, R. / Vicente, T. / Hernández, P. / De Rivas, L. / Conde, F. et al. | 2012
- 1771
-
Erratum to: Photoelectron Thermometry as a Novel Method to Measure Thermodynamic TemperatureKinoshita, I. / Ishii, J. et al. | 2011