Mathematical simulation of an amperometric enzyme-substrate electrode with apO2 basic sensor (English)
National licence
Part 1 Mathematical model and simulation of thepO2 basic sensor
- New search for: Lemke, K.
- New search for: Lemke, K.
In:
Medical and Biological Engineering and Computing
;
26
, 5
;
523-532
;
1988
- Article (Journal) / Electronic Resource
-
Title:Mathematical simulation of an amperometric enzyme-substrate electrode with apO2 basic sensor
-
Subtitle:Part 1 Mathematical model and simulation of thepO2 basic sensor
-
Contributors:Lemke, K. ( author )
-
Published in:Medical and Biological Engineering and Computing ; 26, 5 ; 523-532
-
Publisher:
- New search for: Kluwer Academic Publishers
-
Place of publication:Dordrecht
-
Publication date:1988-09-01
-
Size:10 pages
-
ISSN:
-
DOI:
-
Type of media:Article (Journal)
-
Type of material:Electronic Resource
-
Language:English
-
Keywords:
-
Source:
Table of contents – Volume 26, Issue 5
The tables of contents are generated automatically and are based on the data records of the individual contributions available in the index of the TIB portal. The display of the Tables of Contents may therefore be incomplete.
- 461
-
The clinical engineer: A full member of the health care team?Frize, M. et al. | 1988
- 466
-
Development of a model for point source electrical fibre bundle stimulationAltman, K. W. / Plonsey, R. et al. | 1988
- 476
-
High-frequency oscillatory pressure/flow relationship in the airways of laryngo-tracheo-bronchial tree castsJebria, A. Ben / Choukroun, M. L. / Tabka, Z. / Ultman, J. S. et al. | 1988
- 483
-
Role of viscosity in frequency-dependent reflection from discontinuities in liquid-filled tubesSawatzky, R. P. / Moodie, T. B. et al. | 1988
- 489
-
Dynamic relationship between EMG and torque at the human ankle: Variation with contraction level and modulationGenadry, W. F. / Kearney, R. E. / Hunter, I. W. et al. | 1988
- 497
-
In vitro determination of lung airway compliance in small animalsGreenwald, S. E. / Collino, C. E. / Berry, C. L. et al. | 1988
- 503
-
Effects of some different pulse parameters on the perception of intravaginal and intra-anal electrical stimulationOhlsson, B. L. et al. | 1988
- 509
-
Miniaturised device for long-term intravaginal electrical stimulation for the treatment of urinary incontinenceOhlsson, B. L. / Erlandson, B. -E. et al. | 1988
- 516
-
Self-calibrating interference refractometer using a linear photodiode array for anaesthetic gas analysisJackson, R. K. / Palayiwa, E. / Sugg, B. R. / Hahn, C. E. W. / Weller, S. / Davies, W. L. et al. | 1988
- 523
-
Mathematical simulation of an amperometric enzyme-substrate electrode with apO2 basic sensorLemke, K. et al. | 1988
- 541
-
Oxygen sensitivity of recessed and unrecessed antimony pH microelectrodesKiani, M. F. / Schubert, R. W. et al. | 1988
- 547
-
Joint US—Sweden workshop: The role of university research in the future development of the biomedical industryNerem, R. M. / Öberg, P. Ake / Gruvegård, G. et al. | 1988
- 552
-
Construction of linear resistance units for a model lungMecklenburgh, J. S. et al. | 1988
- 554
-
Microprocessor automatic multiple temperature measurement deviceMahler, Y. / Lifshitz, N. / Nitzan, M. et al. | 1988
- 557
-
Remote vital-signs monitor using a dial-up telephone lineRezazadeh, M. / Evans, N. E. et al. | 1988
- 561
-
Exponential equation to study the fast latency variations of evoked potential waves obtained from young childrenAffinito, M. / Pensiero, S. / Perissutti, P. / Bouquet, F. et al. | 1988